My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
40119 CR 54
Zephyrhills
>
Building Department
>
Building Plans
>
40119 CR 54
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:00:32 PM
Creation date
2/19/2025 8:50:32 AM
Metadata
Fields
Template:
Building Plans
Street #
40119
Location
CR 54
Contractor
Wayne Crawford Construction
Building Plans - Permit #
731
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(D BLDG#2 FLOOR PLAN <br />NKKM SCALE: <br />1/4"=1- -0" <br />- POWER &DATA <br />ELECTRICAL KEYED NOTES:(E <br />1. <br />(AH: 2-2 & 2-3) CONNECT WIRING TO AHU' S <br />5. (I NSTA—HOT) PROVIDE J—BOX AT UNIT. <br />FACTORY INSTALLED BREAKER. BRANCH WIRING SHALL <br />COORDINATE EXACT LOCATION WITH PLUMBER. <br />BE 2#6, 1#10 GND.—3/4"C. <br />PROVIDE 40A/2P LOCKABLE BREAKER AT PANEL (NO <br />SCREWS). BRANCH WIRING SHALL BE 2#8, 1#10 GND. <br />2. <br />(CU: 2-2, 2-3) PROVIDE 60A/2P FUSIBLE <br />—1/2-C. <br />DISCONNECT SWITCH AT UNIT (NEMA 3R) WITH DE <br />FUSES SIZED PER EQUIPMENT MANUFACTURES <br />6. (HWRP) MOUNT AT 60"AFF U. 0. N. COORDINATE <br />RECOMMENDATIONS. BRANCH WIRING SHALL BE 2#8, <br />EXACT LOCATION WITH PLUMBER PRIOR TO ROUGH —IN. <br />1 # 10 GND. —3/4" C. PROVIDE WATER PROOF, GF I <br />SERVICE RECEPTACLE AS INDICATED ON PLANS. <br />3. <br />(ASHRAE 90.1 AUTOMATIC RECEPTACLE CONTROL) <br />PROVIDE DUPLEX RECEPTACLE. CONNECT RECEPTACLES <br />TO TIMECLOCK CONTROL VIA CONTACTOR. TIMECLOCK <br />SHALL BE PROGRAMABLE 7 DAY, 24 HRS. SCHEDULE <br />TIMECLOCKS ON DURING OCCUPIED HOURS. <br />TIMECLOCKS SHALL HAVE 2 HOURS MAX MANUAL <br />OVERRIDE SWITCH. <br />4. <br />(MICRO) PROVIDE 20 AMP 120 VOLT DEDICATED <br />RECESSED RECEPTACLE 60" AFF. FIELD VERIFY <br />EXACT LOCATION PRIOR TO INSTALLATION. BRANCH <br />WIRING SHALL BE 2#12, 1#12 GND.—1/2"C. <br />GENERAL ELECTRICAL NOTES <br />1. THESE PLANS COMPLY WITH FBC C405.6.3, <br />THE CONDUCTORS FOR FEEDERS AND BRANCH <br />CIRCUITS COMBINED SHALL BE SIZED FOR A <br />MAXIMUM OF 5 PERCENT VOLTAGE DROP TOTAL. <br />2. ANY 120V CKT LONGER THAN 75 FEET, <br />INCREASE TO #10 AWG. <br />m BLDG*2 MEZZANINE PLAN - POWER S DATA <br />1 /4" =1' —0" <br />d <br />Z <br />A <br />Orlando, <br />®�®®4®1ii1I 111^, <br />•� • •�tii® <br />0���.. <br />C"i <br />co Q0 <br />co <br />• Z 1� <br />®•Lu ro <br />� <br />d <br />Q <br />do <br />°eC <br />66 <br />Z <br />O <br />Q <br />O <br />It <br />w <br />Z <br />O <br />J <br />L0 <br />o <br />M <br />ou')cl <br />o� <br />p0 <br />�U <br />Z <br />-� <br />J <br />D <br />O= <br />� <br />Cf? <br />r <br />r <br />CD <br />t <br />W <br />N <br />I <br />EXISTING <br />70-9 <br />G <br />M01 <br />d <br />UTILITY O � T ANSFOR E � 0�* <br />CR M R C� M o <br />EXISTING MDP—B z � � <br />�J� <br />E� �I EXISTING MDP—A � Y�< <br />rTI <br />E} EXISTING 75 KVA TRA , SFORMER w DATE: 07/31E20 <br />o^cl PROJECT: 20027/YO037 <br />EXISTING PNL— LA Z '9 DRAWN: D <br />a F NEW 75 KVA TRANSEOR <br />(�ER ♦R �g CHECKED: RS <br />r (4 ,I .. v <br />NEW 400A DISC W/225 FUSES Z <br />. <br />ki <br />■ <br />� BUILDING #2 <br />� PARTIAL B1DG#2 PLAN o POWER POWER&DATA <br />NORTH SCALE: 1%16"=1' —0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.