My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
40119 CR 54
Zephyrhills
>
Building Department
>
Building Plans
>
40119 CR 54
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:00:32 PM
Creation date
2/19/2025 8:50:32 AM
Metadata
Fields
Template:
Building Plans
Street #
40119
Location
CR 54
Contractor
Wayne Crawford Construction
Building Plans - Permit #
731
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n <br />e BLDG #1 FLOOR PLAN - POWER S DATA <br />CU: 1-3 <br />ELECTRICAL KEYED NOTES: <br />1. EXISTING ELECTRICAL DEVICE TO REMAIN. <br />CONTRACTOR SHALL TRACE WIRING TO PANEL, LABLE <br />DEVICE WITH CIRCUIT NUMBERS AND UPDATE PANEL <br />SCHEDULE. <br />2. CONTRACTOR SHALL VERIFY EXISTING GFIC <br />PROTECTION. PROVIDE IF NOT PROTCTED. <br />3. (ASHRAE 90.1 AUTOMATIC RECEPTACLE CONTROL) <br />PROVIDE SWITCHED DUPLEX RECEPTACLE. CONNECT <br />SWITCHED RECEPTACLE TO TIMECLOCK CONTROL VIA <br />CONTACTOR. TIMECLOCK SHALL BE PROGRAMABLE 7 <br />DAY, 24 HRS. SCHEDULE TIMECLOCKS ON DURING <br />OCCUPIED HOURS. TIMECLOCKS SHALL HAVE 2 HOURS <br />MAX MANUAL OVERRIDE SWITCH. <br />4. (ASHRAE 90.1 AUTOMATIC RECEPTACLE CONTROL) <br />PROVIDE DUPLEX RECEPTACLE. CONNECT RECEPTACLES <br />TO TIMECLOCK CONTROL VIA CONTACTOR. TIMECLOCK <br />SHALL BE PROGRAMABL€ 7 DAY, 24 HRS. SCHEDULE <br />TIMECLOCKS ON DURING OCCUPIED HOURS. <br />TIMECLOCKS SHALL HAVE 2 HOURS MAX MANUAL <br />OVERRIDE SWITCH. <br />5. PROVIDE 240 VAC, 40AMP NEMA RECEPTACLE. <br />BRANCH WIRING SHALL BE (3) #8, 1 # 10 GND. —3/4" C. <br />VERIFY RECEPTACLE LOCATION AND CONFIGURATION <br />WITH OWNERS EQUIPMENT PRIOR TO <br />INSTALLATION. PROVIDE NEW 40/2P BREAKER IN <br />PANEL. <br />6. (AH/CU: 1-3) PROVIDE 30A/2P FUSIBLE <br />DISCONNECT SWITCH AT UNIT (NEMA 3R) WITH DE <br />FUSES SIZED PER EQUIPMENT MANUFACTURES <br />RECOMMENDATIONS. BRANCH WIRING SHALL BE 2#10, <br />1 # 10 GND. —1 /2" C. PROVIDE WATER PROOF, GF I <br />SERVICE RECEPTACLE AS INDICATED ON PLANS. <br />GENERAL ELECTRICAL NOTES <br />1. THESE PLANS COMPLY WITH FBC C405.6.3, <br />THE CONDUCTORS FOR FEEDERS AND BRANCH <br />CIRCUITS COMBINED SHALL BE SIZED FOR A <br />MAXIMUM OF 5 PERCENT VOLTAGE DROP TOTAL. <br />2. ANY 120V CKT LONGER THAN 75 FEET, <br />INCREASE TO #10 AWG. <br />Orlando, <br />M <br />®00�®ellrlrrgB'�® <br />co co (0 <br />LL <br />U c)czz <br />* s <br />bo <br />v <br />'11a$$rrrrieaeoo0 <br />U) <br />U <br />0 <br />0� <br />12L <br />O <br />J <br />LO <br />CY) <br />i M <br />b <br />•M <br />go <br />o� <br />ot�� <br />0q <br />M Z. <br />ZL6 <br />F <br />10 <br />x <br />IL <br />WILSO <br />DATE: 07/31 /20 <br />PROJECT: 200271YO037 <br />Z of�� DRAWN: DG <br />� g < CHECKED: RS <br />4WQi <br />Z <br />2 <br />W1 .00 <br />BUILDING #1 <br />POWER & DATA <br />
The URL can be used to link to this page
Your browser does not support the video tag.