Laserfiche WebLink
RUN REFRIGERANT, CONDENSATE, <br />POWER AND CONTROL LINES <br />IN WALL. <br />MOUNTING BRACKET (SEE <br />MANUFACTURE INSTALATION <br />FOR DETAILS). <br />F_ <br />m <br />MOUNT BOTTOM OF AHU AT 6'-8" <br />AFF UNLESS OTHERWISE NOTED. <br />CONDENSATE PUMP <br />WALL (SEE ARCH PLANS FOR TYPE) <br />WALL MOUNTED AHU DETAIL <br />N. T. S. AHU-WALL-MS2 <br />NOTE: <br />1. ALL REFRIGERANT PIPE AND INSULATION SHALL BE INSTALLED <br />SECTION BY SECTION AT THE SAME TIME AND IN CONJUNCTION <br />WITH THE INSTALLATION OF THE PVC REFRIGERANT PIPE CHASE. <br />2. ALL REFRIGERANT PIPING INSTALLED IN THE PVC CHASE SHALL BE <br />CAPPED AND PRESSURE TESTED ACCORDING TO SPECIFICATIONS PRIOR <br />TO INSTALLATION OF CONCRETE SLAB. <br />3. ANCHOR CONDENSING UNIT TO CONCRETE SLAB AS FOLLOWS TO COMPLY <br />WITH 140 MPH WIND LOADING. PROVIDE THREE 1-1/2" 16 GA GALV. <br />STEEL STRAP AT EACH CORNER. SECURE STRAP TO UNIT WITH <br />(2) 3/4"#14 SHEETMETAL SCREWS. SECURE STRAP TO CONCRETE <br />SLAB WITH 1/4"DIA X 2-3/4" RED HEADS. <br />HARD -DRAWN COPPER PIPE COVER <br />REFRIGERANT PIPES. SEE DETAIL SEE NOTE #3 <br />ELECTRICAL CONDUIT <br />EXTERIOR WALL <br />DE I --CONCRETE SLAB <br />CONDENSING UNIT (TO <br />BE INSTALLED ON 1" <br />THICK NEOPRENE ISO- <br />LATION PADS) <br />CONDENSING UNIT PIPING DETAIL <br />N. T. S. <br />WRAP PLENUM BOX WITH <br />1-1/2". R=4.2 DUCT <br />WRAP INSULATION. <br />20 GA GALVANIZED STEEL <br />WALL SLEEVE AND PLENUM <br />BOX. SEAL ALL JOINTS <br />AND SEAMS WATER TIGHT. <br />1-1/2 BY 1-1/2 ANGLE <br />FRAME WITH #10 S. S. SCREWS <br />EVERY 6" 0. C. <br />MOTORIZED DAMPER <br />RUSK I N "CD 35" <br />OUTSIDE AIR M <br />DUCT —� <br />FIN. CEILING <br />SUPPLY AIR DUCT <br />FLEXIBLE CONNECTION <br />RETURN AIR <br />DUCT AIR <br />HANDLING <br />UNIT <br />RUN REFRIGERANT LINES <br />FLEXIBLE C TO CONDENSING UNIT <br />C <br />CONNECTION <br />' C' CHANNEL <br />SUPPORT AS REQ'D CONDENSATE PUMP <br />PROVIDE FLOAT SWITCH IN <br />FIN.FLOOR �'� R/A PLENUM 0 AUX DRAIN TO SHUT OFF AHU <br />BASE IF DRAIN PAN OVERFLOWS. <br />L —if2" DEEP GALV. DRAIN PAN 4" <br />LARGER THAN CONDENSATE PUMP <br />VIBRATION ISOLATION AND UNIT ON ALL 4 SIDES. <br />jM3100 <br />N. T. S. AIR HANDLING UNIT DETAIL 2 <br />M3.00 <br />SEE DUCTWORK AND ACCESSORIES NOTES FOR <br />SPECIFICATION OF DUCT MATERIALS, FASTENING <br />SYSTEM, AND SEALING METHODS. <br />MIN. 4" HIGH VENT <br />2" MIN <br />4" MAX <br />2" <br />SEE SPECIFICATIONS <br />FOR PIPE TYPE AND <br />INSULATION REQUIREMENTS <br />A/C UNIT <br />COIL <br />CONDENSATE DRAIN PAN <br />--- EXTEND CONDENSATE LINE FULL <br />SIZE FROM UNIT CONDENSATE <br />DRAIN CONNECTION <br />(3/4" MINIMUM) <br />CLEANOUT WITH THREADED PIPE CAP <br />SUPF <br />STRI <br />mQr m 1 ur-n AIY 1 <br />ROD,NUT & SUCTION LINE <br />WASHER <br />CONDENSATE TRAP DETAIL PIPE SUPPORT DETAIL <br />N. T. S. N. T. S. <br />NOTE: ALL STRAP SHALL BE <br />A MINIMUM OF 1-1/2", 26 G <br />GALVINIZED STEEL. <br />HANGER WIRE SHALL BE A <br />MINIMUM OF 22 GA. <br />VOLTAGE <br />TROL CONDUIT <br />:NTATE PIPE <br />;ANT <br />. I NE <br />NEOPRENE <br />JG MATERIAL <br />TOPPER <br />1LVANIZED <br />U) <br />U <br />D <br />0 <br />O <br />0� <br />J LO <br />0 m <br />z 0 1 f�► <br />a Yi <br />Q� <br />I <br />O <br />I <br />J <br />LL- <br />J u <br />F. z J <br />z> <br />0 ®_ <br />V <br />W r <br />i— .__I d- N <br />PROVIDE NEOPRENE SHEETING FLANGED FRAME. <br />BETWEEN LOUVER AND PLENUM M <br />BOX. CONNECT W/S. S. SCREWS. /^� <br />B I RDSCREEN `\•/ Z o �+ c <br />m� <br />SLOPE FOR DRAINAGE WHITE h.w <br />GRILL CEILING <br />�✓ M <br />w• � N <br />U. 0n <br />N. CAULK WATER TIGHT ALL Z L6~I o <br />AROUND LOUVER TYPICAL WALL CAP SPEED CO 4 ROLF <br />(SOLID STATE) s <br />W a. <br />W DATE: 07131 /20 <br />_ c946 PROJECT: 7 <br />NOTES: 1. PROVIDE BACKDRAFT DAMPER Wf BIRDSCREEN 2002 /Y0037 <br />2.- FLASH & SEAL WALL AND ROOF CAP Z o � a <br />3.- PROVIDE INTERNAL ISOLATION AND SOUND INSULATION ` w p <br />WALL LOUVER 4.- SUPPORT FAN FROM STRUCTURE leg. <br />CHECKED: DING <br />WITH PLENUM BOX 9 CABINET CEILING FAN DETAIL 10 Z M a <br />� 1, I N. T. S. M3.00 N. T. S. MaOO W <br />V <br />M3000 <br />HVAC DETAILS <br />EXTERIOR WALL SEE ARCH <br />PLANS FOR CONSTRUCTION <br />DETAIL. <br />1 TrIUAL NANUUVU <br />STRAP AND SADDLE <br />HANGING DETAIL <br />NOTE: ALL STRAP SHALL BE <br />A MINIMUM OF 1-1/2, 26 GA <br />GALVINIZED STEEL. WITH A <br />8 FT MAXIMUM SPACING. <br />METHODS OF HANGING <br />d__ RIGID FIGERGLASS DUCTS <br />N. T. S. <br />ALUMINUM <br />WALL LOUVER WITH 1-1/2" <br />TYPICAL ROOF CAP <br />INSULATED <br />PLENUM BOX <br />HANGER WIRE OR STRAP 5' -0" <br />MAX DISTANCE BETWEEN <br />SUPPORTS. MAX. SAG 1 /2" PER <br />FOOT OF SUPPORT SPACING. ��INSULATED DUCT <br />SUPPORTS SHALL BE PROVIDED AL�TE FOR LOW CL.EAR/4NICE <br />WITHIN 18" OF INTERMEDIATE <br />FITTINGS AND BETWEEN N.T.S. <br />MANUAL DAMPER SPIN -IN AINTERMEDIATE FITTINGS <br />AND BENDS. <br />RIGID AIR DUCT: <br />SEE "METHODS OF 1-1/2" GALV. STEEL BAND <br />HANGING DUCTS" CLAMP TO MATCH DUCT 6° SHEETMETAL EXTENSION COLLAR <br />FOR 'REQUIREMENTS DIAMETER BLANKET INSULATION <br />IANNEL WITH ZIP TIE <br />DUCT INSULATED AROUND COLLAR — <br />TAIL FLEXIBLE DUCT n26 GAUGE COLLAR <br />UL-181 CLASS 1 <br />FIN. CILINGAIR DIFFUSER <br />� <br />INSTALL STAINLESS STEEL DUCT CEILING TILE <br />CLAMPS ON BOTH INNER AND OUTER <br />JACKETS. SEAL INNER JACKET AIR SUSPENDED T-BAR <br />TIGHT WITH MASTIC. NYLON DRAWBANDS CEILING GRID SUPPLY AIR GRILLE <br />MAYBE USED IN NON PLENUM AREAS. <br />5 FLEXIBLE DUCT DETAIL <br />N. T. S. ,. SUPPLY AIR GRILLE $ <br />,h <br />M.a.00 WOO N. T. S.F.� <br />VIBRATION HANGER SPRING TYPE <br />W/NEOPRENE ISOLATOR <br />3/8" THREADED <br />RODS SHEETMETAL <br />DUCTWORK <br />