ELECTRICAL SPECIFICATIONS <br />1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, <br />EQUIPMENT, ACCESS PANELS, CONTROL SYSTEMS, DEVICES, PERMITS <br />AND SERVICES NECESSARY FOR FURNISHING AND INSTALLING OF A <br />COMPLETE SERVICEABLE ELECTRICAL SYSTEM. <br />2. ALL ELECTRICAL SYSTEMS ARE TO BE INSTALLED IN <br />ACCORDANCE WITH THE 2014 EDITION OF THE NATIONAL <br />ELECTRICAL CODE, ALL APPLICABLE SECTIONS OF THE NFPA <br />STANDARDS, THE LOCAL BUILDING CODE, PLANS AND <br />SPECIFICATIONS. <br />3. ALL MATERIALS SHALL BE NEW (UNLESS OTHERWISE INDICATED) <br />AND ANY DAMAGED EQUIPMENT SHALL BE REPLACED. <br />4. CONTRACTOR WILL WARRANTY ALL MATERIALS AND WORKMANSHIP <br />FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (1) ONE YEAR <br />FROM THE DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS <br />SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL <br />INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE <br />INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. <br />5. PROVIDE SUBMITTALS IN PDF FORMAT FOR REVIEW BY <br />ARCH/ENGR PRIOR TO PURCHASING ANY EQUIPMENT OR MATERIALS. <br />SUBMITTALS SHALL INCLUDE ALL ITEMS AND MATERIALS SUPPLIED BY <br />CONTRACTOR. SUBMITTALS SHALL HAVE A SUMMARY SHEET SHOWING <br />ALL SCHEDULED INFORMATION. ANY EQUIPMENT OR MATERIALS <br />INSTALLED WITHOUT REVIEWED SUBMITTALS SHALL BE REMOVED AND <br />REINSTALL AT ARCH/ENGR DISCRETION WITH NO ADDITIONAL <br />COMPENSATION TO CONTRACTOR. <br />6. PROVIDE 2 SETS OF MAINTENANCE AND OPERATION MANUALS ON <br />ALL ELECTRICAL EQUIPMENT OR SYSTEMS. <br />7. DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED. <br />REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT <br />LOCATION OF ALL EQUIPMENT. ELECTRICAL CONTRACTOR SHALL <br />FURNISH AND INSTALL ALL ITEMS REQUIRED FOR A COMPLETE AND <br />ACCEPTABLE WORKING INSTALLATION. <br />8. CONTRACTOR SHALL COORDINATE ALL ELECTRICAL SERVICE <br />REQUIREMENTS WITH POWER COMPANY PRIOR TO INSTALLING ANY <br />EQUIPMENT. COORDINATION SHALL INCLUDE BUT NOT BE LIMITED <br />TO, POWER CO. TRANSFORMER LOCATION, TRANSFORMER A. I . C. <br />RATING, POWER METER TYPES, METER DISCONNECT REQUIRMENTS, AND <br />EQUIPMENT INSTALLATION HEIGHT REQUIREMENTS. <br />9. MINIMUM WIRE SIZE SHALL BE #12 AWG IN 1/2" CONDUIT, <br />UNLESS OTHERWISE NOTED. ALL CONDUCTORS SHALL BE COPPER WITH <br />THWN OR THHN INSULATION. SEPARATE WIRE AND CONDUIT SYSTEM <br />MAY BE SUBSTITUTED WITH FACTORY FABRICATED ASSEMBLY OF <br />INSULATED CONDUCTORS IN A FLEXIBLE METALLIC ENCLOSURE WHERE <br />PERMITTED BY LOCAL CODES. <br />10. ALL MATERIAL SHALL BE NEW AND BEAR THE UNDERWRITES <br />LABEL (U. L. ) WHERE APPLICABLE. <br />11. THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND <br />EFFECTIVELY GROUNDED AS REQUIRED IN ARTICLE 250 OF THE <br />NATIONAL ELECTRICAL CODE. <br />12. THE ELECTRICAL, TELEPHONE, AND CABLE TELEVISION <br />INSTALLATIONS SHALL MEET ALL REQUIREMENTS BY THE LOCAL <br />UTILITY COMPANIES. <br />13. ALL DISCONNECT SWITCHES SHALL BE RATED FOR 100,000 <br />A.I.C. UNLESS OTHERWISE NOTED. ALL FUSES SHALL BE RATED FOR <br />200,000 A. I . C. AND SHALL BE CURRENT LIMITING. <br />14. ALL ELECTRICAL SWITCHGEAR SHALL BE BY SQUARE D, GE, OR <br />SIEMENS. SUBSTITUTES MUST BE APPROVED BY THE ENGINEER. <br />15. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS. <br />PLASTIC BOXES MAY BE USED IN LIEU OF THE STEEL BOX WHERE <br />PERMITTED BY LOCAL CODES. IN DAMP OR WET LOCATIONS BOXES <br />SHALL BE MADE FROM CAST ALLOY WITH THREADED HUBS. SPECIAL <br />ENCLOSURES ARE REQUIRED FOR OTHER CLASSIFIED AREAS. USE <br />"3M" MPP+ PUTTY PADS PER THEIR LISTING FOR ALL OUTLET BOXES <br />IN 1 AND 2 HOUR RATED GYPSUM BOARD WALL ASSEMBLIES. <br />16. MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC WITH <br />OVERLOAD RELAYS IN EACH HOT LEG. IT SHALL BE THE ELECTRICAL <br />CONTRACTOR TO PROVIDE ALL STARTERS WHERE REQUIRED. <br />17. FURNISH AND INSTALL DISCONNECT SWITCHES, OVER CURRENT <br />PROTECTION, AND WIRING FOR THE AIR CONDITIONING SYSTEM AS <br />PER MANUFACTURER RECOMMENDATIONS. CONTROLS ARE TO BE <br />SUPPLIED BY THE AIR CONDITIONING CONTRACTOR AND CONNECTED BY <br />THE ELECTRICAL CONTRACTOR. <br />18. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL <br />CONTRACOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE <br />SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTED BY THE ENGINEER <br />OR ARCHITECT. <br />ELECTRICAL LEGEND <br />LIGHTING TROFFER - LETTER INDICATES TYPE <br />® <br />EMERGENCY TROFFER - LETTER INDICATES TYPE <br />Do <br />DOWN LIGHTING FIXTURE - LETTER INDICATES TYPE <br />Do <br />EMERGENCY DOWN LIGHTING FIXTURE - LETTER INDICATES TYPE <br />X 0 <br />EMERGENCY EXIT LIGHT - LETTER INDICATES TYPE <br />X/EM <br />COMBINATION EMERGENCY EXIT LIGHT AND EMERGENCY LIGHTING <br />UNIT- LETTER INDICATES TYPE <br />EM I=� <br />EMERGENCY LIGHTING UNIT - LETTER INDICATES TYPE <br />$ <br />SINGLE POLE TOGGLE SWITCH - MOUNT 48" AFF U.O.N. <br />$3 <br />THREE WAY SWITCH - MOUNT 48" AFF U. 0. N. <br />$4 <br />FOUR WAY SWITCH - MOUNTED 48" AFF U. 0. N. <br />$a <br />SINGLE POLE SWITCH - MOUNTED 48" AFF U. 0. N. <br />LOWER CASE LETTER INDICATES CONTROL AREA <br />INCANDESCENT DIMMER SWITCH - MOUNTED 48"AFF U.O.N. <br />WATTAGE AS REQUIRED BY CIRCUIT CAPACITY <br />WALL MOUNTED OCCUPANCY SENSOR <br />® <br />PROVIDE WITH LIGHTING PACKAGE TO MATCH LIGHT TYPES <br />MOUNT 48" AFF U. 0. N. <br />® <br />CEILING MOUNTED OCCUPANCY SENSOR <br />PROVIDE WITH LIGHTING PACKAGE TO MATCH LIGHT TYPES <br />WALL MOUNTED OCCUPANCY SENSOR WITH DIMMER <br />® <br />PROVIDE WITH LIGHTING PACKAGE TO MATCH LIGHT TYPES <br />MOUNT 48" AFF U. 0. N. <br />0= <br />DUPLEX RECEPTACLE - MOUNTED 18" AFF U.O.N. <br />@= <br />DUPLEX RECEPTACLE - MOUNTED 5" A.C.B. U.O.N. <br />Q= <br />SWITCHED DUPLEX RECEPTACLE - MOUNTED 18"AFF U.O.N. <br />SWITCHED DUPLEX RECEPTACLE - MOUNTED 6" A. C. B. U.O.N. <br />DOUBLE DUPLEX RECEPTACLE - MOUNTED 18" AFF U.O.N. <br />DOUBLE DUPLEX RECEPTACLE - MOUNTED 6" A.C.B. U. 0. N. <br />DUPLEX RECEPTACLE - MOUNTED FLUSH TO CEILING <br />DUPLEX RECEPTACLE - IN FLOOR BOX WITH COVER, <br />COVER TO BE FLUSH WITH FINISHED FLOOR <br />a <br />DOUBLE DUPLEX RECEPTACLE - IN FLOOR BOX WITH COVER, <br />COVER TO BE FLUSH WITH FINISHED FLOOR <br />® <br />SPECIAL PURPOSE OUTLET OR EQUIPMENT CONNECTION <br />COMMUNICATIONS RACEWAY - MOUNTED 18" AFF U.O.N. <br />d <br />PROVIDE 2 GANG BOX WITH ONE GANG RING <br />STUB 3/4" CONDUIT 6" ABOVE CEILING U.O.N. <br />COMMUNICATIONS RACEWAY - MOUNTED 6" A.C.B. U.O.N. <br />A <br />PROVIDE 2 GANG BOX WITH ONE GANG RING <br />STUB 3/4" CONDUIT 6" ABOVE CEILING U.O.N. <br />COMMUNICATIONS RACEWAY - IN FLOOR BOX WITH COVER <br />Q <br />COVER TO BE FLUSH WITH FINISHED FLOOR <br />STUB 3/4" CONDUIT 6" ABOVE CEILING U. O. N. <br />�Q <br />FIRE ALARM HORN AND STROBE, "34" INDICATES REQUIRED <br />34 <br />EFFECTIVE INTENSITY (cd), IF NOT INDICATED OUTPUT IS "15" <br />FIRE ALARM STROBE ONLY <br />E] <br />FIRE ALARM PULL STATION <br />0 <br />JUNCTION BOX, MOUNT FLUSH TO FINISHED SURFACE U.O.N. <br />MOTOR <br />LEI <br />DISCONNECT SWITCH <br />0 <br />ELECTRICAL PANEL <br />TBB <br />TELEPHONE BACKBOARD W/#6 CU GND U.O.N. ( SIZE AS NOTED) <br />® <br />KEYED NOTE (SEE LIST) <br />SOLID LINE INDICATES EQUIPMENT ON COMMON BRANCH CIRCUIT <br />AND/OR CONTROLLED BY COMMON SWITCH. EACH CIRCUIT SHALL <br />CONSIST OF A PHASE CONDUCTOR, NEUTRAL AND GROUND <br />CONDUCTOR. CONTRACTOR SHALL PROVIDE NECESSARY SWITCH <br />LEGS IN CONDUIT TO ATTAIN SWITCHING ARRANGEMENTS <br />INDICATED ON PLANS. CONTRACTOR MAY COMBINE CIRCUITS <br />INTO COMMON HOMERUN(S) CONSISTING OF A COMMON <br />NEUTRAL AND GROUND CONDUCTOR AND THREE PHASE <br />CONDUCTORS (A, B, AND C PHASE) . <br />DOTTED LINE INDICATES EQUIPMENT ON COMMON BRANCH CIRCUIT <br />BUT NOT CONTROLLED BY SAME SWITCH OR OTHER SIMILAR DEVICE. <br />THE FOLLOWING ABBREVIATIONS INDICATES: <br />E EXISTING <br />R RELOCATE <br />RE/CKT REUSE EXISTING CIRCUIT <br />C. L. CENTER LINE <br />U. 0. N. UNLESS OTHERWISE NOTED <br />G OR GFI GROUND FAULT INTERRUPTER <br />WP WEATHERPROOF <br />IG ISOLATED GROUND <br />NL NIGHT LIGHT <br />C/T CURRENT TRANSFORMER <br />AFF ABOVE FINISHED FLOOR <br />AFG ABOVE FINISHED GRADE <br />A. C. B. ABOVE COUNTER BACKSPLASH <br />BFG BELOW FINISHED GRADE <br />N. T. S. NOT TO SCALE <br />N. I. C. NOT IN CONTRACT <br />U RECEPTACLE WITH (1) USB-A AND (1) USB-C <br />OUTLET/CHARGER. <br />NOTE: ALL MOUNTING HEIGHTS INDICATED ARE <br />TO THE CENTERLINE OF THE DEVICE U.O.N. <br />LIGHTING FIXTURE SCHEDULE <br />MARK <br />LAMP DATA <br />DESCRIPTION <br />FIXTURE MODEL NUMBER <br />MOUNT <br />VOLT <br />NOTES <br />QTY <br />TYPE <br />MANUFACTURER <br />CATALOG NUMBER1 <br />A <br />INC <br />20W 24L <br />2X2 LED T-BAR <br />LITHONIA <br />CPANL 2X2 35K DIM <br />RECESSED <br />277 <br />AEN <br />INC <br />20W 24L <br />2X2 LED T-BAR W/BATT-NL <br />LITHONIA <br />CPANL 2X2 35K DIM PS1055CP <br />RECESSED <br />277 <br />2,3 <br />BES <br />INC <br />20W 24L <br />2X2 LED T-BAR W/BATT <br />LITHONIA <br />CPANL 2X2 35K DIM PS1055CP <br />RECESSED <br />277 <br />2,5 <br />B <br />INC <br />32W 40L <br />2X4 LED T-BAR <br />LITHONIA <br />CPANL 2X4 35K DIM <br />RECESSED <br />277 <br />BEN <br />INC <br />32W 40L <br />2X4 LED T-BAR W/BATT-NL <br />LITHONIA <br />CPANL 2X4 35K DIM PS1055CP <br />RECESSED <br />277 <br />2.3 <br />BES <br />INC <br />32W 40L <br />2X4 LED T-BAR W/BATT <br />LITHONIA <br />CPANL 2X4 35K DIM PS1055CP <br />RECESSED <br />277 <br />2,5 <br />C <br />1 <br />IOW/FT LED <br />12" COVE LIGHT <br />TROV <br />L35I12-10-277V <br />SURFACE <br />277 <br />D <br />1 <br />16.3W LED <br />6" LED DOWNLIGHT-IC <br />JUNO <br />K22LEDG4-14LM-35K <br />RECESSED <br />277 <br />7 <br />DEN <br />1 <br />16.3W LED <br />6" LED DOWNLIGHT-IC WITH BATT <br />JUNO <br />K22LEDG4-14LM-35K-EM <br />RECESSED <br />277 <br />2,3,7 <br />E <br />EXISTING FIXTURE <br />EXISTING <br />277 <br />6 <br />S <br />1 <br />14.7W LED <br />6" LED SHOWER DOWNLIGHT <br />GOTHAM <br />EV06SH-35-15DFF-SOL-EZ1 <br />RECESSED <br />277 <br />7.8 <br />X <br />INC <br />INC <br />UNIVERSAL LED EMERGENCY EXIT <br />LITHONIA <br />LQMSW3REL <br />UNIVERSAL <br />277 <br />2.3 <br />EM <br />INC <br />INC <br />EMERGENCY BATTERY UNIT <br />LITHONIA <br />6ELM2 <br />UNIVERSAL <br />277 <br />2,3,4 <br />LIGHTING FIXTURE NOTES: <br />1. GENERAL SCHEDULE NOTES (APPLIES TO ALL FIXTURES): <br />A) CONTRACTOR SHALL COORDINATE FIXTURE MOUNTING WITH ARCHITECTURAL REFLECTED CEILING PLAN(S) <br />AND SHALL PROVIDE FIXTURE MOUNTING AS REQUIRED TO MATCH CEILING TYPE. <br />B) ALL FIXTURES BALLAST SHALL BE HIGH POWER FACTOR TYPE. <br />C) ALL FLUORESCENT BALLAST SHALL BE ENERGY SAVING TYPE. <br />D) ALL ELECTRICAL FIXTURES MUST BE INDEPENDENTLY SUPPORTED OF CEILING GRID. LIGHT FIXTURES WEIGHTING <br />LESS THAN 10 POUNDS SHALL HAVE AT LEAST ONE 12 GAGE HANGER WIRE CONNECTED FROM THE FIXTURE TO THE <br />STRUCTURE ABOVE. LIGHTS WEIGHTING MORE THAN 10 POUNDS SHALL HAVE AT LEAST TWO 12 GAGE WIRES ATTACHED <br />AT OPPOSING CORNERS OF THE LIGHT FIXTURE. <br />E) CONTRACTOR SHALL PROVIDE AND INSTALL LIGHTING FIXTURE DISCONNECT MEANS IN ACCORDANCE WITH NEC-410.73(G). <br />DISCONNECTING MEANS SHALL BE PROVIDED IN INDOOR LOCATIONS, OTHER THAN DWELLINGS AND ASSOCIATED <br />ACCESSORY STRUCTURES, FOR FLUORESCENT LUMINARIES (FIXTURES) THAT UTILIZE DOUBLE ENDED LAMPS AND <br />CONTAIN BALLAST(S) THAT CAN BE SERVICED IN PLACE OR BALLASTED LUMINARIES THAT ARE SUPPLIED FROM <br />MULTIWIRE BRANCH CIRCUITS AND CONTAIN BALLAST(S) THAT CAN BE SERVICED IN PLACE SHALL HAVE A <br />DISCONNECTING MEANS EITHER INTERNAL OR EXTERNAL TO EACH LUMINAIRE (FIXTURE), TO DISCONNECT <br />SIMULTANEOUSLY FROM THE SOURCE OF SUPPLY ALL CONDUCTORS OF THE BALLAST, INCLUDING THE GROUNDED <br />CONDUCTOR IF ANY. THE LINE SIDE TERMINALS OF THE DISCONNECTING MEANS SHALL BE GUARDED. THE <br />DISCONNECTING MEANS SHALL BE LOCATED SO AS TO BE ACCESSIBLE TO QUALIFIED PERSONS BEFORE <br />SERVICING OR MAINTAINING THE BALLAST. <br />F) PROVIDE SUBMITTALS ON ALL FIXTURES. ANY FIXTURE INSTALLED WITHOUT SUBMITTAL APPROVAL <br />IS SUBJECT TO BEING REPLACED WITH NO ADDITIONAL COMPENSATION TO CONTRACTOR. <br />G) CONTRACTOR SHALL VERIFY EXISTING CEILING RATING PRIOR TO ORDERING ANY FIXTURES. <br />REPORT ANY DISCREPANCIES TO ARCHITECT AND ENGINEER. <br />2. FIXTURES TO BE PROVIDED WITH INTEGRAL EMERGENCY BATTERY BACK-UP. <br />3. FIXTURES SHALL BE CONNECTED TO CONSTANT NORMAL ROOM LIGHTING BRANCH CIRCUIT OF AREA SERVED <br />(i.e. LOAD SIDE OF BREAKER, LINE SIDE OF ANY SWITCHING/CONTROLLING DEVICES). <br />4. FIXTURE TO BE WALL MOUNTED 7'-6" AFF TO TOP. <br />5. FIXTURES TO BE PROVIDED WITH INTEGRAL EMERGENCY BATTERY BACK-UP. THE EMERGENCY BALLAST SHALL BE <br />CONNECTED TO CONSTANT NORMAL ROOM LIGHTING BRANCH CIRCUIT OF AREA SERVED (i.e, LOAD SIDE OF BREAKER, <br />LINE SIDE OF ANY SWITCHING/CONTROLLING DEVICES). THE LIGHT FIXTURE IS TO BE COMPLETELY SWITCHED AND <br />THE EMERGENCY BALLAST OPERATES ONLY IN THE EVENT OF A BRANCH CIRCUIT POWER FAILURE. <br />6. EXISTING FIXTURE TO BE CLEANED, RELAMPED, NEW BALLAST, AND NEW BATTERY AS REQUIRED FOR A COMPLETE OPERATING <br />SYSTEM. <br />7. IC RATED. <br />8. UL RATED FOR WET LOCATIONS. <br />L F 0 VISUAL SIGNAL DEVICE <br />----- i <br />NEW DEVICES NE HORN AND STROBE <br />DUCT SMOKE DETECTOR, NOTIFIER <br />EXISTING DEVICES FACP1 FIRE ALARM CONTROL PANEL <br />EXISTING SMOKE DETECTOR, NOTIFIER <br />F.A.C.P <br />PULL STATION <br />EXISL- d -J ING <br />BUILDING TDEVICES FS FLOW SWITCH <br />FIRE ALARM SYSTEM SHALL BE INSTALLED Q TAMPER SWITCH <br />PER ALL LOCAL CODES. <br />F.A.C.P-FI E ALARM CONTROL PANEL, FIRE BELL <br />ADDRESSIBLE). <br />NOTE: F. A. C. P. SHALL HAVE FAAP ANNUNCIATOR PANEL <br />BATTERY BACKUP. <br />FIRE ALARM RISER <br />NTS <br />FIRE ALARM SYSTEM REQUIREMENTS <br />CONTRACTOR SHALL PROVIDE AND INSTALL NEW FIRE ALARM DEVICES AS SHOWN <br />AND SHALL CONNECT ALL DEVICES TO THE EXISTING FIRE ALARM SYSTEM AS <br />REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. CONTRACTOR SHALL PROVIDE <br />A COMPLETE AND OPERABLE FIRE ALARM SYSTEM AS REQUIRED BY GOVERNING <br />STATE, NFPA AND LOCAL CODES. COMPLETE FIRE ALARM SYSTEM SHALL BE <br />INSTALLED IN ACCORDANCE WITH THE LATEST GOVERNING EDITIONS OF NFPA 72 <br />AND 101 AND THE FLORIDA BUILDING CODE. CONTRACTOR SHALL INCLUDE IN HIS <br />BID ALL WORK NECESSARY TO PREPARE COMPLETE INSTALLATION DRAWINGS <br />SIGNED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER AS NEEDED <br />FOR BUILDING PERMIT AS REQUIRED BY THE LOCAL AUTHORITIES HAVING <br />JURISDICTION. CONTRACTOR SHALL COORDINATE ALL WORK NECESSARY FOR <br />EQUIPMENT BEING PROVIDED. CONTRACTOR SHALL BE RESPONSIBLE FOR <br />COMPLETE AND OPERABLE SYSTEM. <br />941 Lake Baldwin <br />Orlando, FL 32814 <br />1 <br />®`®®®d®IIIIIIIIJO®o <br />Co <br />L <br />•. <br />:2 r <br />coUJ <br />O; <br />Q <br />a <br />°F % <br />J 9111P10®®®`0 <br />U <br />O <br />am <br />O <br />V7 <br />n M <br />UM <br />o <br />Zo <br />ao• <br />oi� <br />0 <br />w <br />� <br />C <br />r� 1& <br />U M�Z <br />a <br />Z_j�� <br />o <br />W <br />5 <br />W IL owc <br />W DATE: 07/31 /20 <br />o 4 6 PROJECT: 20027NO037 <br />Z N�g DRAWN: DG <br />W g o CHECKED: RS <br />W � <br />Z M=g <br />V LJJ <br />3mOO <br />NOTES, LEGEND, <br />-N%%O*,j AND LIGHT SCHEDULE <br />