My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
40119 CR 54
Zephyrhills
>
Building Department
>
Building Plans
>
40119 CR 54
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:00:32 PM
Creation date
2/19/2025 8:50:32 AM
Metadata
Fields
Template:
Building Plans
Street #
40119
Location
CR 54
Contractor
Wayne Crawford Construction
Building Plans - Permit #
731
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
------� <br />I I <br />r------------------ <br />I EXISTING "MDP" I <br />EXISTING <br />;--------i---------I <br />I I EXISTING "MB" I <br />800A MCB <br />( 3) #4/0 CU THWN <br />500A MCB <br />(1) #4 CU GND <br />IN 2-1/2" C. <br />i 120/208/3PH <br />EXISTING <br />NEMA 1 i <br />(2) SETS OF <br />i i NEMA 1 <br />I --------- ----a <br />i ---- - <br />(4) #250 MCM CU THWN <br />I --------- <br />I I <br />(1) #2/0 CU GND <br />1----------r--------- 1 <br />EACH SET IN A 2-1/2" C. <br />r------------------- I <br />I i---------- ----------i <br />I , <br />, EXISTING <br />150 KVA TRANS <br />r--------�---------� <br />" <br />� T" i ---- <br />--� r------------------� <br />I I 225/3P I <br />I 3PH/4W I <br />I I I <br />Cr-}---L--- <br />I I <br />----a PRIM: 480 V <br />I 1 <br />I <br />r ---------------- I <br />I I <br />I SECOND: 208Y/120V I <br />I <br />I--------a--I <br />; 300/3P I <br />I <br />L—j-----------------J <br />300------- <br />3P <br />I / I <br />I <br />9 <br />I <br />I <br />1�� <br />L--------i--� I <br />t--J <br />4— #2/0 CU, 3/4" C. <br />I <br />I <br />L--------1--------J <br />I <br />I I <br />—i— <br />I I <br />_- I <br />-- <br />- I <br />PERL ------------------------------------------------------------------ <br />NEC <br />BLDG *1 PARTIAL ELECTRICAL RISER <br />NTS <br />a <br />EXISTING <br />( 4) #350 CU jr-1 <br />( 1) #4 CU GNC <br />I N 3" C. <br />r-------- i <br />,EXISTING, <br />PANEL , <br />I "cot I <br />I 100/3P I <br />_ I Cry}--1 <br />NEMA 1 <br />L-------- J <br />EXISTING <br />) #3 CU THWN <br />1) #8 CU GND <br />IN 1-1/2 C. <br />r-------- I <br />',EXISTING, <br />, PANEL , <br />! "DP" ! <br />EXISTING <br />( 4) #350 CU THWN <br />( 1) #4 CU GND <br />IN 3" C. <br />r--------� <br />,EXISTING', <br />PANEL , <br />1 "E" I <br />277/480 <br />3 PH <br />C <br />PANEL <br />'DP <br />VOLTAGE: <br />BUS RATING: <br />MAINS: <br />MOUNTING: <br />A I.Q RATING <br />1201208V,3PK,4W <br />225 AMP <br />100A MCB <br />SEE PLANS <br />EYJSTING <br />LOADS (WATTS) <br />CKT <br />C N <br />PHASE <br />C N <br />CKT <br />LOADS (WATTS) <br />LOAD SERVED <br />BRKR <br />K O <br />K O <br />BRKR <br />LOAD SERVED <br />LTS <br />RECPT <br />MOTOR <br />HEAT <br />AMP1P <br />A <br />B <br />C <br />AMPIP <br />LTS <br />RECPT <br />MOTOR <br />HEAT <br />T. <br />T. <br />payroll comp recept <br />720 <br />e2011 <br />1 <br />- <br />- <br />2 <br />e2011 <br />720 <br />rw computer recept <br />se computer recept <br />720 <br />e2011 <br />3 <br />* <br />- <br />4 <br />e2011 <br />720 <br />n computer recept <br />se center comp recept <br />720 <br />e20M <br />5 <br />- <br />- <br />* <br />6 <br />e2011 <br />720 <br />a coputer recept <br />se wa1 comp recept <br />720 <br />e2011 <br />7 <br />* <br />- <br />- <br />8 <br />e2011 <br />720 <br />sw computer recept <br />9 <br />- <br />- <br />10 <br />e2011 <br />720 <br />sw computer recept <br />11 <br />- <br />12 <br />e3011 <br />720 <br />sw computer recept <br />13 <br />* <br />- <br />- <br />14 <br />4012 <br />3000 <br />EQUIPMENT <br />15 <br />- <br />* <br />- <br />16 <br />-- <br />3000 <br />-- <br />17 <br />- <br />* <br />18 <br />4012 <br />3000 <br />EQUIPM 13IT <br />19 <br />* <br />- <br />- <br />20 <br />-- <br />3000 <br />--_ <br />21 <br />- <br />* <br />- <br />22 <br />4012 <br />3000 <br />EQUIPMENT <br />23 <br />- <br />- <br />* <br />24 <br />-- <br />3000 <br />---- <br />25 <br />* <br />- <br />26 <br />2512 <br />1839 <br />AWCU:1-3 <br />27 <br />- <br />* <br />- <br />28 <br />-- <br />1839 <br />_-- <br />29 <br />- <br />- <br />* <br />30 <br />2011 <br />540 <br />RECEPT <br />31 <br />* <br />- <br />- <br />32 <br />2011 <br />360 <br />RECEPT <br />33 <br />- <br />* <br />- <br />34 <br />2011 <br />180 <br />RECEPT <br />35 <br />- <br />- <br />36 <br />37 <br />* <br />- <br />- <br />38 <br />e10013 <br />main <br />39 <br />- <br />* <br />- <br />40 <br />41 <br />- <br />- <br />* <br />42 <br />-- <br />- <br />LTS <br />RECPT MOTORS <br />HEAT <br />LTS <br />RECPT <br />MOTOR <br />HEAT <br />0 <br />2890 0 <br />0 <br />SUBTOTALS <br />01 <br />234001 <br />36781 <br />0 <br />PHASE LOADING <br />LTS <br />RECPT <br />MOTORS <br />HEAT <br />LTS <br />RECPT MOTORS <br />HEAT <br />0.0 <br />26.3 <br />3.7 <br />0.0 <br />CONNECTED KW TOTALS <br />PHASEA <br />0 <br />9240 1839 <br />0 <br />125 <br />18.1 <br />1.00 <br />1.25 <br />DEMAND <br />PHASES <br />0 <br />8340 1839 <br />0 <br />NOTES: <br />0.0 <br />18.1 <br />3.7 <br />0.0 <br />ADJUSTED KW TOTALS <br />PHASE C <br />0 <br />8700 0 <br />0 <br />(] <br />INDICATES NON -CONCURRENT A/C LOAD. <br />30.0 <br />TOTAL CONNECTED ION <br />A B <br />C <br />SIM BASED ON <br />LARGEST LOAD. <br />21.8 <br />TOTAL ADJUSTED KW <br />PHASE TOTALS <br />11079 10179 <br />8700 <br />'H7 <br />INDICATES HACR <br />RATED BREAKER. <br />THREE PHASE VOLTAGE <br />08103/20 <br />DATE <br />JOBNAME: <br />'G' <br />INDICATES GR BREAKER. <br />[]161 <br />TOTAL PANEL <br />0320 PM <br />13ME <br />LATHAM POOLS <br />'L' <br />INDICATES LOCKABLE BREAKER. <br />AMPERAGE: <br />GENERAL ELECTRICAL NOTES <br />1. THESE PLANS COMPLY WITH FBC C405.6.3, <br />THE CONDUCTORS FOR FEEDERS AND BRANCH <br />CIRCUITS COMBINED SHALL BE SIZED FOR A <br />MAXIMUM OF 5 PERCENT VOLTAGE DROP TOTAL. <br />2. ANY 120V CKT LONGER THAN 75 FEET, <br />INCREASE TO #10 AWG. <br />NOTE: RISER DIAGRAM IS SCHEMATIC ONLY. <br />CONTRACTOR IS TO LAYOUT EQUIPMENT TO <br />MEET ALL NEC AND POWER CO REQUIREMENTS. <br />CONTRACTOR SHALL VERIFY THAT ALL EXISTING <br />COMPONENTS ARE AS SHOWN ON RISER AND MEET <br />NEC REQUIREMENTS. REPORT ANY <br />DISCRECPENCIES TO ARCH/OWNER. <br />941 Lake Baldwin Lane <br />Orlando, FL 32814 <br />t 321.441.3320 <br />0 <br />®co:Go (0 oco <br />' <br />Aoaw c W <br />° Q <br />®P • eC, <br />oP <br />F <br />ONSULTANT: <br />0 <br />Itt <br />Ln <br />rfN <br />o <br />Z Lb 0 <br />O Q O� <br />o- <br />n o ° <br />ry J LL <br />40 ^ W2 >- (6 <br />V.jJ F <br />Q < ZOf J <br />0 _ °ry <br />M <br />UJ w _ <br />~ ow <br />? _I ,-t N <br />dM <br />So <br />Z %q <br />oz� <br />V 0 <br />N Z <br />M p <br />ZL6 <br />1O <br />W <br />Wpot <br />0-!! <br />W DATE: 07/31 /20 <br />PROJECT: 20027/Y0037 <br />Z N t DRAWN: DG <br />fig` CHECKED: RS <br />_o <br />� W <br />Z � <br />z 00 <br />Q M o <br />0 =. <br />W' <br />3 0 <br />RISERS AND <br />PANEL SCHEDULES <br />
The URL can be used to link to this page
Your browser does not support the video tag.