TYPICAL CONSTRUCTION NOTES <br />GENERAL: PREFABRICATED WOOD TRUSSES <br />1. OWNER/BUILDER/CONTRACTOR TO VERIFY ALL DETAILS AND <br />DIMENSIONS PRIOR TO CONSTRUCTION <br />2. PROVIDE (1) No. 5 ELECTRICAL GROUND TO FOUNDATION STEEL <br />3. ALL WORK SHALL CONFORM TO FLORIDA BUILDING CODE - <br />RESIDENTIAL 7TH EDITION (2020) <br />4. OWNER/BUILDER/CONTRACTOR SHALL PROVIDE ALL MEASURES <br />NECESSARY TO PROTECT STRUCTURE(S) AND ALL PERSONS <br />DURING CONSTRUCTION. HE/THEY SHALL SUPERVISE AND <br />DIRECT ALL WORK AND BE RESPONSIBLE FOR ALL CONSTRUCTION. <br />5. OWNER/BUILDER/CONTRACTOR SHALL COORDINATE ARCHITECTURAL, <br />MECHANICAL, AND ELECTRICAL DRAWINGS FOR ANCHORS, EMBEDS <br />AND SUPPORTS OR ANY OTHER ITEMS WHICH AFFECT THE <br />STRUCTURAL DRAWINGS. <br />6. EXTERIOR USE OF CEMENT PLASTER (STUCCO) SHALL COMPLY WITH <br />THE APPLICATION REQUIREMENTS OF ASTM C 926 <br />SITE PREPARATION: <br />1. ALL ORGANIC AND REFUSE MATERIALS AND/OR SOFT AREAS SHALL <br />BE REMOVED AND SOIL PREPARED TO AN ALLOWABLE BEARING <br />PRESSURE OF 2000 P.S.F.. <br />2. ANY CONDITIONS WHICH COULD PREVENT THE ATTAINMENT <br />OF 2000 P.S.F. SHALL BE NOTED TO THE ARCHITECT AND <br />ENGINEER IMMEDIATELY. <br />SLABS ON GRADE: <br />1. COMPACT INTERIOR FILL TO 95% MINIMUM OF MODIFIED <br />PROCTOR MAXIMUM DRY DENSITY ASTM D1557 OPTIMUM <br />MOISTURE CONTENT. SOIL COMPACTION SHALL BE <br />FIELD CONTROLLED BY A REPRESENTATIVE FROM A <br />QUALIFIED LABORATORY APPROVED BY THE ENGINEER. <br />EACH LAYER OF FILL SHALL NOT EXCEED 10" AND <br />SHALL BE COMPACTED PRIOR TO PLACEMENT OF <br />NEXT FILL LAYER. <br />2. ALL FLOOR SLABS SHALL BE PLACED UPON A <br />4" THICK SAND LAYER FOR FINE GRADING. <br />3. 6 MIL POLY VAPOR BARRIER SHALL BE PLACED <br />OVER TERMITE PROTECTED FILL PRIOR <br />TO FOOTING OR SLAB POURS. <br />CONCRETE AND REINFORCING: <br />1. ALL CONCRETE WORK SHALL CONFORM TO ACI STANDARD <br />BUILDING CODES FOR REINFORCED CONCRETE (ACI 318-14) <br />2. ALL CONCRETE SHALL HAVE A MINIMUM FC = 2000 P.S.I. <br />WITH PREFERRED FC = 2500 P.S.I. AT 28 DAYS, <br />INCLUDING SLABS, FILLED CELLS AND LINTELS <br />3. FOUNDATION DESIGN IS BASED ON A MINIMUM SOIL BEARING <br />CAPACITY OF 2500 P.S.F.. <br />4. REBARS SHALL CONFORM TO ASTM A-615 GRADE 40, AND <br />25" MINIMUM LAP AT ALL JOINTS. SLABS WITH FIBER MESH <br />FABRIC SHALL CONFORM TO ASTM A-185 <br />5. VERTICAL WA REBAR <br />E LL REINFORCING SHALL BE STANDARD HOOK <br />WITH A PROJECTION OF 25" MINIMUM ABOVE SLAB AND A <br />7" MINIMUM EMBEDMENT. <br />6. ALL STANDARD REINFORCING STEEL 90 HOOKS SHALL EXTEND <br />AT LEAST (12) BAR DIAMETERS BEYOND THE BEND. <br />EXTENSION LEG = 10" FOR No. 5 REBAR, 14" FOR No. 7 REBAR <br />AND 12" FOR No 3 REBAR <br />7. ALL VERTICAL REINFORCEMENT SHALL TIE INTO FOUNDATION STEEL <br />BY MEANS OF (1) No.5 REBAR WITH STANDARD HOOK AND <br />TIE INTO CONTINUOUS BOND BEAM BY MEANS OF (1) STANDARD <br />HOOK (25" LAP MINIMUM). <br />8. COVERAGE FOR REINFORCEMENTS SHALL BE AS FOLLOWS: <br />FOOTING 3" MIN, SLABS ON GRADE 1 1/2" FROM TOP, LINTELS AND <br />BOND BEAMS 1 1/2" FROM TOP (ON STIRRUPS) <br />9. ACI-318-08 BUILDING REQUIREMENTS FOR REINFORCED CONCRETE <br />AISC CODE OF STANDARD PRACTICE: <br />MANUAL OF STEEL CONSTRUCTION, 9TH EDITION S-301 SPECIFICATIONS <br />FOR THE DESIGN, FABRICATION AND ERECTION OF STEEL <br />FOR BUILDINGS INCLUDING SUPPLEMENTS <br />SPECIFICATIONS FOR STRUCTURAL JOINTS USING <br />ASTM A-325 BOLTS STRUCTURAL WELDING CODE AWS D1.1 <br />AISI SPECIFICATIONS FOR DESIGN OF LIGHT GAUGE <br />COLD FORMED ASHRA E FOR MECHANICAL WORK <br />OTHER STANDARDS LISTED IN THEIR RESPECTIVE <br />SECTIONS IN SPECIFICATIONS <br />MASONRY: <br />1. MASONRY CONSTRUCTION SHALL CONFORM TO ACI STANDARD <br />BUILDING CODES FOR MASONRY STRUCTURES (ACI 530-13), <br />2. CONCRETE BLOCKA BLOCKS ND S SHALL I6-11 SPECIFICATIONS) <br />C1 ) FORM TO ASTM C9028 DAY <br />STRENGTH EQUAL TO 2000 P.S.I. , FM = 1500 P.S.I. LAID <br />IN RUNNING BOND <br />3. ALL VERTICAL REINFORCING BARS SHALL BE TIED TO <br />FOOTING DOWELS AND BOND BEAM WITH STANDARD HOOK. <br />ENTIRE BUILDING ENVELOPE IS SHEARWALL. SHALL BE <br />CONSIDERED TO BE SHEARWALL SEGMENTS. <br />4. MORTAR SHALL BE TYPE "S" OR "M". <br />5. WHERE SHOWN, VERTICAL CELLS SHALL BE POURED SOLID <br />WITH GROUT AT MINIMUM COMPRESSIVE STRENGTH OF <br />2500 P.S.I. AT 28 DAYS, GROUT SLUMP NOT LESS THAN 8" <br />AND REINFORCED WITH MINIMUM No.5 REBAR AND <br />25" MINIMUM OVERLAP. <br />6. GROUT FOR FILLED CELLS SHALL BE POURED OR PUMPED IN <br />LIFTS NOT TO EXCEED TEN (10) FEET IN HEIGHT, AND SHALL BE <br />CONSOLIDATED AT TIME OF POURING BY RODDING <br />OR VIBRATING. <br />7. PROVIDE KNOCKOUT IN CMU AT BASE OF EACH FILLED CELL <br />FOR VISUAL VERIFICATION OF COMPLETE GROUT PENETRATION. <br />STRUCTURAL LUMBER: <br />1. SEE TRUSS TABLE FOR ANCHORAGE. <br />2. GRAVITY LOADS WERE TAKEN INTO ACCOUNT IN DESIGN <br />3. ALL STRUCTURAL AND LOAD BEARING LUMBER SHALL HAVE <br />A MINIMUM Fb = 1200 P.S.L. <br />4. ANY WALLS GREATER THAN 9 FEET HIGH SHALL HAVE NO LESS <br />THAN ONE INTERMEDIATE BRIDGING SPACED NO MORE THAN <br />72" APART. <br />5. ALL LOAD BEARING WALLS SHALL HAVE DOUBLE SOUTHERN YELLOW <br />PINE #2 TOP PLATES. SOLE PLATES ON MASONRY SHALL BE <br />SALT SOLUTION PRESSURE TREATED. STUDS 16" O.C. MAX <br />6. ALL OTHER BEARING LUMBER SHALL BE No. 2 SOUTHERN YELLOW PINE <br />AND SHALL BE BASED ON MAXIMUM SPANS FOR RAFTERS AND JOISTS <br />7. NON BEARING WALLS SHALL HAVE STUDS 24" O.0 MAX <br />8. FURRING STRIPS SHALL BE 16" TO 24" O.C. <br />STRUCTURALSTEEL: <br />1. STEEL WORK SHALL CONFORM TO THE AISC SPECIFICATIONS FOR <br />THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL <br />STEEL FOR BUILDINGS LATEST EDITION. <br />2. STRUCTURAL STEEL SHALL CONFORM TO ASTM-36 <br />INTERIOR GENERAL NOTES: <br />1. DOMESTIC CLOTHES DRYER DUCTS SHALL HAVE A SMOOTH INTERIOR <br />FINISH WITH JOINTS RUNNING THE DIRECTION OF THE AIRFLOW. <br />THE MAXIMUM LENGTH SHALL NOT EXCEED 25 FEET (7260 MM) <br />FROM THE DRYER LOCATION TO THE DISCHARGE TERMINAL. <br />THE MAXIMUM LENGTH OF THE DUCT SHALL BE REDUCED 30" <br />(762 MM) FOR EACH 45 (0.79 RAD) BEND AND 5 FEET (1524 MM) <br />FOR EACH 90 (1.6 RAD) BEND. THE EXHAUST DUCT SHALL BE <br />A MINIMUM SIZE OF 4 (102 MM) IN DIAMETER. THE ENTIRE EXHAUST <br />SYSTEM SHALL BE SUPPORTED AND SECURED IN PLACE. <br />FLEXIBLE DUCT CONNECTORS USED IN CONNECTIONS WITH <br />DOMESTIC DRYER SHALL BE METALLIC, NOT MORE THAN 6 FEET <br />(1829 MM) IN LENGTH AND AN APPROVED TYPE. FLEXIBLE DUCT <br />CONNECTORS SHALL NOT BE CONCEALED WITH IN CONSTRUCTION. <br />2. ALL WATER CLOSETS TO BE 1.6 GALLON MAXIMUM. <br />3. ALL SLIDING GLASS DOORS TO BE TEMPERED. ALL GLASS <br />WITHIN 24" OF A DOOR SHALL BE TEMPERED. ALL GLASS IN <br />WET AREAS SUCH AS BATHROOMS AND KITCHENS SHALL BE <br />TEMPERED. <br />4. UNLESS OTHERWISE NOTED, ANGLED WALLS ARE 45 . <br />5. ALL MEDICINE CABINETS ARE RECESSED AND BOTTOMS ARE <br />SET AT 54" AFF. SIZE: 14" X 18" UNLESS NOTED OTHERWISE. <br />6. CONSIDER ALL APPLIANCES ELECTRIC UNLESS NOTED. <br />7. 50 GALLON WATER HEATER UNLESS NOTED. <br />8. ALL CEILINGS INCLUDING GARAGE AND PORCHES TO BE 1/2" GYP <br />9. ALL CEILING HEIGHTS ARE FROM FINISHED FLOOR 0'-0" AFF <br />1. WOOD ROOF TRUSSES SHALL BE DESIGNED BY AN <br />ENGINEER REGISTERED IN THE STATE OF FLORIDA. <br />SIGNED AND SEALED TRUSS CALCULATIONS AND <br />DRAWINGS SHALL BE SUBMITTED TO THE PROJECT <br />ENGINEER FOR APPROVAL PRIOR TO FABRICATION. <br />DRAWINGS SHALL INCLUDE CRITICAL DIMENSIONS FOR <br />DETERMINING FIT AND PLACEMENT. DESIGN LOADING <br />CRITERIA IS SHOWN IN THE GENERAL NOTES ON THIS <br />DRAWING. <br />2. ALL TRUSSES AND OTHER ROOF STRUCTURAL <br />COMPONENTS SHALL BE FABRICATED IN A PROPERLY <br />EQUIPPED MANUFACTURING FACILITY OF A PERMANENT <br />NATURE. ALL TRUSSES SHALL BE FABRICATED UNDER <br />STRICT RULES OF THE TRUSS PLATE INSTITUTE (T.P.I.) <br />3. TRUSSES SHALL BE HANDLED WITH CARE SO THEY <br />ARE NOT DAMAGED. HORIZONTAL BENDING SHALL BE <br />KEPT TO A MINIMUM DURING ERECTION. <br />4. INSTALL ERECTION BRACING TO HOLD THE TRUSSES TRUE <br />AND PLUMB DURING CONSTRUCTION. <br />5. TRUSS FRAMING HARDWARE NOT SHOWN ON THE DRAWINGS <br />SHALL BE DESIGNED BY THE TRUSS ENGINEER. ALTERNATE <br />CONNECTORS TO THOSE SHOWN ON THE DRAWINGS MAY BE <br />SUBMITTED FOR APPROVAL. <br />6. TRUSSES SHALL BE FABRICATED FROM THE FOLLOWING <br />MATERIALS: <br />a. CHORDS SHALL BE A MINIMUM SIZE OF 2x4 AND SHALL <br />BE #2 SOUTHERN YELLOW PINE OR BETTER. <br />b. WEBS AND BRACING SHALL BE A MINIMUM SIZE OF 2x4 <br />AND SHALL BE #3 SOUTHERN YELLOW PINE OR BETTER. <br />c. TRUSS PLATES SHALL BE 20 GAGE MINIMUM WITH A <br />MINIMUM YIELD OF 33,000 PSI AND SHALL BE G60, <br />COMMERCIAL CLASS HOT DIPPED GALVANIZED BEFORE <br />STAMPING. <br />7. MAXIMUM ALLOWABLE TRUSS DEFLECTION DUE TO THE <br />SUPERIMPOSED LIVE AND DEAD LOADS SHOWN IN THE <br />GENERAL NOTES OF THE CONSTRUCTION DOCUMENTS, <br />INCLUDING SELF WEIGHT OF THE TRUSS, SHALL BE <br />AS FOLLOWS: <br />a. ATTACHED TO PLASTER = L/360 <br />b. ELSEWHERE = L/240 <br />SECTION R318: PROTECTION AGAINST TERMITES <br />R318.1 TERMITE PROTECTION <br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED <br />TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, <br />BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER <br />APPROVED METHODS OF TERMITE PROTECTION LABELED <br />FOR USE AS A PRESERVATIVE TREATMENT TO NEW CONSTRUCTION. <br />SEE SECTION 202, REGISTERED TERMITICIDE. UPON <br />COMPLETION OF THE APPLICATION FO THE TERMITE <br />PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE <br />SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST <br />CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: <br />"THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR <br />THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS <br />IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE <br />FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES" <br />INCLUDING ALL ADDITIONAL CODES R138.1.1 THRU R318.1.8 <br />R318.2 PENETRATION <br />PROTECTIVE SLEEVES AROUND PIPING PENETRATING CONCRETE <br />SLAB -ON -GRADE FLOORS SHALL NOT BE OF CELLULOSE -CONTAINING <br />MATERIALS. IF SOIL TREATMENT IS USED FOR SUBTERRANEAN <br />TERMITE PROTECTION, THE SLEEVE SHALL HAVE A MAXIMUM <br />WALL THICKNESS OF 0.010 INCH (0.25mm), AND BE SEALED <br />WITHIN THE SLAB USING A NONCORROSIVE CLAMPING DEVICE <br />TO ELIMINATE THE ANNULAR SPACE BETWEEN THE PIPE <br />AND THE SLEEVE. NO TERMITICIDES SHALL BE APPLIED INSIDE THE SLEEVE. <br />R318.3 CLEANING <br />CELLS AND CAVITIES IN MASONRY UNITS AND AIR GAPS <br />BETWEEN BRICK, STONE OR MASONRY VENEERS AD THE <br />STRUCTURE SHALL BE CLEANED OF ALL NON PRESERVATIVE -TREATED OR <br />NON -NATURALLY DURABLE WOOD, OR OTHER CELLULOSE -CONTAINING <br />MATERIAL PRIOR TO CONCRETE PLACEMENT. INCLUDING ALL EXCEPTIONS. <br />R318.4 CONCRETE BEARING LEDGE <br />NOT APPLICABLE TO THIS PROJECT <br />R318.5 PROTECTION AGAINST DECAY AND TERMITES <br />CONDENSATE LINES, IRRIGATION/SPRINKLER RISERS FOR SPRAY <br />HEADS, AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST <br />1 FOOT (305mm) AWAY FROM THE STRUCTURE SIDEWALL, <br />WHEATHER BY UNDERGROUND PIPING, TAIL EXTENSIONS <br />OR SPLASH BLOCKS. GUTTERS WITH DOWNSPOUTS ARE <br />REQUIRED ON ALL BUILDINGS WITH EAVES OF LESS THAN <br />6 INCHES (152mm) HORIZONTAL PROJECTION EXCEPT FOR <br />GABLE END RAKES OR ON A ROOF ABOVE. <br />R318.6 PREPARATION OF BUILDING SITE AND REMOVAL OF DEBRIS <br />INCLUDE ALL CODES R318.6.1 THRU R318.6.3 <br />R318.7 INSPECTIONS FOR TERMITES <br />IN ORDER TO PROVIDE FOR INSPECTION OF TERMITE INFESTATION, <br />CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL EARTH <br />GRADE ON THE EXTERIOR OF A BUILDING SHALL NOT BE LESS THAN 6 INCHES <br />(152mm). INCLUDING ALL EXCEPTIONS <br />R318.8 FOAM PLASTIC PROTECTION <br />IN AREAS WHERE THE PROBABILITY OF TERMITE INFESTATION IS "VERY HEAVY". <br />AS INDICATED IN FIGURE R301.2(6), EXTRUDED AND EXPANDED POLYSTRENE, <br />POLYISOCYANU RATE AND OTHER FOAM PLASTICS SHALL NOT BE INSTALLED ON <br />THE EXTERIOR OF FACE OR UNDER INTERIOR OR EXTERIOR FOUNDATION WALLS <br />OR SLAB FOUNDATION LOCATED BELOW GRADE. THE CLARENCE BETWEEN FOAM <br />PLASTICS INSTALLED ABOVE GRADE AND EXPOSED EARTH SHALL BE AT LEAST <br />6 INCHES (152 mm). INCLUDING ALL EXCEPTIONS <br />DISCLAIMER: <br />PLANS, NOTES, SPECIFICATIONS, DETAILS AND ALL OTHER INFORMATION <br />DEPICTED ON THIS SHEET AND ALL ATTACHED SHEETS HAS BEEN <br />PREPARED TO MEET FBC STANDARDS LATEST EDITION. IT IS THE <br />RESPONSIBILITY OF THE OWNER/ BUILDER/CONTRACTOR TO VERIFY LOCAL, <br />COUNTY AND STATE CODE ENFORCEMENT AGENCIES, COMPLIANCE WITH <br />BUILDING CODES AND ORDINANCES FOR CONSTRUCTION. ANY CHANGES <br />MADE TO THE PLANS AFTER APPROVAL BY GOVERNING AREA MUST BE <br />DONE SO WITH THE CONSENT OF DESIGN PROFESSIONAL ANY CHANGES <br />MADE WITHOUT CONSENT WILL FORFEIT THE DESIGN PROFESSIONAL FROM <br />ANY LEGAL CONTINGENCIES WHICH MAY RESULT FROM CHANGES. <br />GENERAL NOTES <br />1. DO NOT SCALE THESE DRAWINGS, IT SHALL BE THE RESPONSIBILITY OF THE <br />CONTRACTOR TO CHECK ALL DIMENSIONS AND VERIFY THE BUILDING POSITION <br />WITH IN THE SETBACK LINES PRIOR TO COMMENCING CONSTRUCTION. <br />2. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO FAMILIARIZE <br />HIMSELF WITH ALL EXISTING CONDITIONS. ALL EXISTING CONDITIONS ARE <br />NOT NECESSARILY SHOWN HEREON. <br />3. ALL TRADES SHALL BE RESPONSIBLE TO READ ALL DETAILS AND SPECIFICATIONS, <br />AND PLANS - ARCHITECTURAL, STRUCTURAL, MECHANICAL, ETC. FOR PROPER <br />COORDINATION. IF ANY CONFLICTS EXIST, THAT TRADE SHALL NOTIFY THE <br />CONTRACTOR OF THE SAME, PRIOR TO CONSTRUCTION. <br />4. THE CONTRACTOR SHALL DIRECT ANY DISCREPANCIES TO THE ARCHITECT PRIOR <br />TO CONSTRUCTION, AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR WORK <br />WHICH PROCEEDS WITHOUT DUE COURSE AND COORDINATION. <br />5. ACCESSIBILITY REQUIREMENTS: ACCESSIBLE BATHROOM DOORS SHALL HAVE A <br />29" CLEAR OPENING - A 2'-8" DOOR PROVIDES A 29" MIN. CLEAR OPENING. <br />ALL BATHROOMS ARE ACCESSIBLE IN THIS FLOOR PLAN. <br />6. EGRESS WINDOWS ARE SHOWN ON THE PLANS AND <br />ELEVATIONS. <br />7. CONTRACTOR TO FIELD VERIFY ALL ROUGH OPENING FOR ALL OPENINGS <br />AND COORD WITH WINDOW AND DOOR ORDER/ INSTALL, TYP. <br />NOTE: <br />ALL STRUCTURAL & MISC. STEEL TO BE A36 U.N.O. <br />Fy = 40 KSI. (UNLESS NOTED OTHERWISE) <br />STRUCTURAL DESIGN CRITERIA <br />DESIGN CONFORMS TO FLORIDA BUILDING CODE <br />7TH EDITION 2020 (RESIDENTIAL) <br />DESIGN WIND VELOCITY: 145 MPH <br />WIND IMPORTANCE FACTOR: 1.0 <br />BUILDING CATEGORY - OCCUP CHAP 3. : RESIDENTIAL LESS THAN 33' : YES <br />WIND EXPOSURE: C / DIRECTION (ALL) RISK CATEGORY: II (FBC TABLE 1604.5) <br />CONSTRUCTION TYPE: V-B <br />COMPONENT & CLADDING DESIGN WIND PRESSURES: SEE TABLES ON THIS PAGE <br />ROOF LIVE LOAD 20 PSF <br />FLOOR LIVE LOAD 40 PSF <br />FLOOR DEAD LOAD (WOOD) : 20 PSF <br />FLOOR DEAD LOAD (CONCRETE) : 55 PSF <br />CONCRETE (AT 28 DAYS): 3000PSF (SEE SPECS) <br />REINFORCING STEEL: REFER TO SPECS, DRAWINGS <br />STRUCTURAL STEEL: ASTM A-36 (U.O.N.) ANY DISCREPANCY CONTACT ARCHITECT/ ENG., TYP. <br />LUMBER MIN. : 1150 <br />USE (MINIMUM) SOUTHERN PINE NO. 2 OR DOUGLAS FIR NO. 2. PRESSURE TREATED (PT) <br />AS INDICATED. <br />SOIL BEARING PRESSURE 2000 PER SQ. FT. SEE FOUNDATION PLAN <br />TO BE FIELD VERIFIED PRIOR TO PLACING FOOTING REINFORCEMENT <br />OR CONCRETE POUR - NOTIFY DESIGNER IMMEDIATELY IF SOIL FAILS TO <br />STRUCTURAL DESIGN SHALL BE IN COMPLIANCE WITH THE FBC 7TH EDITION 2020, RESIDENTIAL. <br />AND LOCAL ORDINANCE AND REGULATIONS. <br />145 MPH ENCLOSURE EXP B ALLOWABLE STRESS DESIGN <br />THIS PLAN HAS BEEN DESIGNED TO COMPLY WITH ALL PROVISIONS OF THE FBC-2020 <br />INCLUSIVE OF ASCE 7-16 WIND PROVISIONS FOR A NOMINAL DESIGN (3 SEC GUST) <br />OF 145 MPH (Vult). AS DEFINED IN SECTION 1609, THIS STRUCTURE MEET <br />THE REQUIRMENT FOR AN ENCLOSED BUILDING AND AS SUCH BEEN DESIGNED W/ AN INTERNAL <br />PRESSURE COEFFICIENT OF +18 AND -18, UNADJUSTED FOR ZONES 1.2.3. DESIGN HAS UTILIZED <br />A WIND IMPORTANCE FACTOR OF 1.0 FOR BUILDING CATEGORY II IN AN EXPOSURE B WITH A MEAN <br />ROOF HGT OF 30 FEET AND COMPLIES W/ WIND SPEED MAPS ADOPTED BY LOCAL JURISDICTION. <br />WINDOWS, DOORS, COMPONENTS, DESIGN WIND PRESSURES (ENCLOSED BUILDING) <br />70NF. I OCAI WINDOW SUPPI IFR TO VERIFY ACCFPTARI F WINn MAP <br />Basic wind speed = 145 mph <br />Wind importance factor = 1 Live Load Floor = 40 PSF Live Load Roof = 20 PSF <br />Building category = II Dead Load Floor = 15 PSF Dead Load Roof = 22 PSF <br />Wind Exposure = B <br />Internal Pressure Coefficient = +/ 0.18 <br />COMPONENT AND CLADDING WIND LOADS BASIC WIND SPEED V MPH - 3 SECOND GUST = 160 <br />Effective <br />Roof Angle <br />Wind <br />Area <br />0-7 Degrees <br />7-27 Degrees <br />27-45 Degrees <br />Wall <br />(SQFT) <br />1 <br />2 <br />3 <br />1 <br />2 <br />3 <br />1 <br />2 <br />1 3 <br />4 <br />5 <br />10 <br />11.21-27.0 <br />11.21-46.0 <br />11.21-69.0 <br />15.9/-25.0 <br />153.9/-44.0 <br />15.91-65.0 <br />25.3/-27.0 <br />25.31-32.0 <br />25.302.0 <br />27.700.0 <br />27.707.0 <br />20 <br />10.61-26.0 <br />10.6141.0 <br />10.6/-57.0 <br />14.51-24.0 <br />14.5/40.0 <br />14.51-60.0 <br />24.61-26.0 <br />24.600.0 <br />24.61-30.0 <br />26.41-28.0 <br />26.404.0 <br />50 <br />10.01-26.0 <br />10.01-34.0 <br />10.0141.0 <br />12.7/-23.0 <br />12.705.0 <br />12.71-55.0 <br />23.61.24.0 <br />23.61-29.0 <br />23.61-29.0 <br />24.71-27.0 <br />24.71-31.0 <br />100 <br />10.01-25.0 <br />10A/-30.0 <br />10.01-30.0 <br />11.21-22.0 <br />11.21-32.0 <br />11.21-51.0 <br />22.91-22.0 <br />22.91-27.0 <br />22.91-27.0 <br />23.51-25.0 <br />23.51-28.0 <br />500 <br />1 <br />1 <br />1 <br />20.61-22.0 <br />20.61-22.0 <br />LOADS TAKEN FROM TABLE r301.2(2) FROM THE 2020 FLORIDA RESIDENTIAL BUILDING CODE <br />2. HURRICANE PROTECTION AT OPENINGS. PROVIDE WOOD STRUCTURAL PANELS (7/16" Min.) PER SECTION <br />R301.2.1.2 OF THE 2020 FLORIDA RESIDENTIAL BUILDING CODE <br />ROOF WIND ZONES <br />DESIGN PRESSURES FOR THE ROOF ZONES ARE TAKEN FROM THE <br />MOST CONSERVATIVE CASE. (INCLUDING ROOF SLOPE, EFFECTIVE <br />AREA AND VERHANG CONDITIONS) <br />ZONE 1 +23.75 -25.5 <br />ZONE 2 +23.75 -3.00 <br />ZONE 3 +23.75 -30.0 <br />1. ANY WINDOW, ALL OR PART, WHICH IS WITHIN 6' OF A CORNER <br />SHALL BE CONSIDERED ZONE 5 PER CHART ABOVE, ALL OTHER <br />WINDOWS ARE CLASSIFIED IN ZONE 4. <br />2. ROUND AREA DOWN TO THE LARGEST PRESSURE IN THE CHART ABOVE. <br />DESIGN PRESSURES ABOVE REPRESENT THE NET PRESSURE (SUM OF <br />EXTERNAL AND INTERNAL PRESSURES) APPLLIED NORMAL TO ALL <br />SURFACES. COMPONENT MANUFACTURER SHALL USE THE HIGHER OF THE <br />TWO NUMBERS FOR APPLICABLE SQUARE FOOTAGE. <br />GENERAL ROOF LOADING <br />SHINGLE <br />METAL <br />TILE <br />HEAVY <br />ROOF (PSF) <br />ROOF (PSF) <br />ROOF (PSF) <br />ROOF (PSF) <br />TOP CHORD LL <br />20 <br />20 <br />20 <br />20 <br />TOP CHORD DL <br />10 <br />10 <br />15 <br />25 <br />BOTTOM CHORD LL* <br />0 <br />0 <br />0 <br />0 <br />BOTTOM CHORD DL <br />10 <br />10 <br />10 <br />10 <br />TOTAL (PSF) <br />40 <br />40 <br />45 <br />55 <br />BOTTOM CHORD LL (OPT) <br />ATTICS W/ LIMITED STORAGE <br />20 <br />ATTICS W/ HEAVY STORAGE <br />50 <br />* ATTICS W/ NO STORAGE <br />10 <br />(NON -CONCURRENT) <br />NOTE: LL REDUCTIONS ARE ALLOWED PER CODE BUT ONLY WITH <br />WRITTEN <br />APPROVAL FROM FOR OR INDICATED ON PLAN <br />GENERAL FLOOR LOADING <br />TOP CHORD LL <br />40 PSF <br />COMMENTS: <br />TOP CHORD DL <br />10 PSF <br />BOTTOM CHORD LL <br />0 PSF <br />BOTTOM CHORD DL <br />5 PSF <br />BUILDING CODE CRITERIA <br />FLORIDA BUILDING CODES: <br />NEW BUILDING CODE: <br />FLORIDA BUILDING CODE -BUILDING 7TH EDITION (2020) <br />FLORIDA BUILDING CODE-RESIDENTAL 7TH EDITION (2020) <br />ELECTRICAL CODE: <br />NATIONAL ELECTRICAL CODE 2017 <br />PLUMBING CODE: <br />FLORIDA BUILDING CODE -PLUMBING 7TH EDITION (2020) <br />MECHANICAL CODE: <br />FLORIDA BUILDING CODE -MECHANICAL 7TH EDITION (2020) <br />GAS CODE: <br />FLORIDA BUILDING CODE -FUEL GAS 7TH EDITION (2020), <br />NFPA 58 LIQUIFIED PETROLEUM GASES LATEST EDITION <br />NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS. <br />LATEST EDITION OSHA <br />ACCESSIBILITY CODE: <br />FLORIDA BUILIDING CODE -ACCESSIBILITY 7TH EDITION (2020) <br />ENERGY CODE: <br />FLORIDA BUILDING CODE -ENERGY CONSERVATION 7TH EDITION (2020) <br />FIRE CODES: <br />FLORIDA FIRE PREVENTION CODE WITH CURRENT FBC EDITION (2020) <br />FL APPROVAL CODES <br />SIMPSON: <br />HGUM = 13904 <br />AB44 = 10849.1 <br />BC4 = 10860.2 <br />H 10A = 11478.2 <br />HUC410 = 10655.78 <br />HETA20 = 11473 <br />CC46 = 10860 <br />WINDOWS & DOORS: <br />SINGLE HUNG WINDOWS: FL16103 <br />PICTURE WINDOWS: FL16104 <br />SINGLE DOOR INSWING: FL20461.1 <br />DOUBLE DOOR OUTSWING: FL20461.3 <br />ALL WINDOW AND DOOR GLAZING TO <br />BE IMPACT RESISTANT <br />ALL FLORIDA PRODUCT APPROVALS HAVE BEEN VERIFIED FOR <br />APPROVAL AND MEETS FBC 2020 7th EDITION. <br />IF APPLICABLE, THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY PATRICK SULLIVAN, AIA AS INDICATED USING A DIGITAL SIGNATURE. o <br />azo <br />awo <br />UjO]N <br />A PROPOSED RESIDENCE FOR: a0 <br />3 - <br />zz``' <br />O L <br />< O <br />a <br />�zo <br />wao <br />NoOTS 6 AND 7 <br />z5� <br />PARCEL NUMBER: 11-26-21-0010-113 00-0060 z <br />J (N Q <br />aFo <br />Nwo <br />�w <br />LOCATED AT: <br />o <br />18th STREET <br />w U <br />}oQ <br />_j <br />W <br />,aa <br />�M <br />ZEPHYRHIL <br />LS <br />FL <br />= }mO <br />- <br />33542 <br />PASCO COUNTY, FL <br />ZEPHYRHILLS, FLORIDA <br />OVERALL LOCATION MAP: <br />NOT TO SCALE <br />GEOTECHNICAL DISCLAIMER: SUBSURFACE INFORMATION ON THESE <br />DRAWINGS WAS PROVIDED BY OTHERS. THE ACCURACY OF THIS <br />INFORMATION IS NOT GUARANTEED AND IT IS NOT TO <br />CONSTRUCTED AS PART OF THE PLANS GOVERNING CONSTRUCTION <br />OF THE PROJECT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR <br />TO INQUIRE WITH [OWNER] IF ADDITIONAL INFORMATION IS <br />AVAILABLE TO MAKE ARRANGEMENTS TO REVIEW THE SAME PRIOR <br />TO BIDDING, TO CONDUCT WHATEVER SITE INVESTIGATION OR <br />TESTING THAT MAY BE REQUIRED, AND TO MAKE OWN <br />DETERMINATIONS AS TO ALL SUBSURFACE CONDITIONS. <br />NOTE: <br />1. ALL AREAS WHERE WATER AND OR MOISTURE IS INDICATED <br />OR KNOWN TO BE WILL REQUIRE 1/2" MOISTURE RESISTANT <br />GYPSUM BOARD. ASTM C1396 & ASTM C 630 <br />WATER-RESISTANT GYPSUM BACKING BOARD. <br />2. STUCCO SHALL BE APPLIED PER ASTM C926, STANDARD <br />SPECIFICATION FOR APPLICATION OF PORTLAND <br />CEMENT -BASED PLASTER. ASTM C 1063 STANDARD <br />SPECIFICATION FOR INSTALLATION OF LATHING AND FURRING <br />TO RECEIVER INTERIOR AND EXTERIOR PORTLAND <br />CEMENT -BASED PLASTER. STUCCO HAS A MIN 7/8" <br />THICKNESS AND ALL HORIZONTAL REINFORCEMENT AS PER <br />ASTM STANDARDS AND LOCAL GOVERNING CODES. <br />3. HORIZONTAL REINFORCEMENT FOR EVERY OTHER COURSE PER <br />ASTM AND LOCAL GOVERNING CODES. <br />MATERIAL SYMBOLS LIST <br />CONCRETE BLOCK <br />RIGID <br />INSULATION <br />2X FRAMED <br />WALLS <br />GRAVEL <br />FINISHED <br />/ / / <br />/��� <br />UNDISTURBED <br />WOOD <br />EARTH <br />D` <br />PLYWOOD <br />> <br />CONCRETE <br />® <br />BATT OR <br />BLOWN IN <br />STUCCO OR <br />INSULATION <br />GYP BD <br />SYMBOLS & <br />ABBREVIATIONS <br />CENTER LINE ] ELEVATION NUMBER <br />SHEET NUMBER <br />ELEVATION MARKER <br />q SECTION LETTER <br />X❑ LINTEL CALL OUT 4.3 <br />SHEET NUMBER <br />A.F.F. ABOVE FINISHED FLOOR INT. INTERIOR <br />B.F.F. BELOW FINISHED FLOOR S.F. SQUARE FOOTAGE <br />CLG CEILING TYP. TYPICAL <br />(SYP) NO.2 SOUTHERN <br />YELLOW PINE <br />I <br />COMPLIANCE NOTES: <br />TO THE BEST OF OUR KNOWLEGE AND <br />BELIEF, THESE PLANS ARE IN <br />COMPLIANCE WITH THE FLORIDA <br />BUILDING CODE 2020, SEVENTH EDITION <br />TO THE BEST OF MY KNOWLEDGE <br />AND BELIEF THESE DRAWINGS ARE <br />IN COMPLIANCE WITH THE STATE <br />OF FLORIDA MINIMUM BUILDING <br />CODES INCLUDING: <br />2020 MECHANICAL CODE, SEVENTH EDITION <br />2020 PLUMBING CODE, SEVENTH EDITION <br />FL FIRE PREVENTION CODE LATEST EDITION AND, <br />THE 2017 NATIONAL ELECTRICAL CODE <br />THE 2020 LIFE SAFETY CODE, SEVENTH EDITION <br />THE 2020 FLORIDA BUILDING CODE EXISTING, SEVENTH EDITION <br />SHEET INDEX <br />PERMIT SET <br />AO-00 <br />COVER SHEET / CODE DATA <br />AO-01 <br />GENERAL SPECS <br />AO-02 <br />GENERAL SPECS <br />Al -01 <br />FOUNDATION AND PLUMBING PLANS <br />A2-01 <br />EXTERIOR ELEVATIONS <br />A2-02 <br />FLOOR PLAN AND SCHEDULES <br />A8-01 <br />ROOF PLAN <br />A8-02 <br />BUILDING SECTIONS <br />A8-03 <br />BUILDING SECTIONS <br />S 1 -01 <br />DETAILS <br />S1-02 <br />DETAILS <br />AS-01 <br />ARCHITECTURAL SITE PLAN <br />q✓ c+ <br />> <br />SQUARE <br />FOOTAGE CALCULATIONS <br />PROPOSED RESIDENCE ....... 1,370 SQ. FT. LIVING SPACE <br />REAR PORCH ....... 150 SQ. FT. <br />FRONT PORCH ....... 164 SQ. FT. <br />PROJECT TOTAL ........................... 1,684 SQ. FT. <br />SCOPE OF WORK: <br />- NEW CONSTRUCTION OF A THREE BEDROOM, <br />- TWO BATHROOM RESIDENTIAL RESIDENCE. <br />PARCEL NUMBER FOR PROJECT LOCATION: <br />11-26-21-0010-11300-0060 STATUS: VACANT <br />DESIGN PROFESSIONAL NOTES <br />DESIGN PROFESSIONAL REVIEW AND APPROVAL OF TRUSS <br />INFORMATION AND LINTEL INFORMATION IS BASED UPON THE <br />INFORMATION CONTAINED HEREIN. SHOULD THE OWNER OR <br />CONTRACTOR CHANGE TRUSS COMPANIES OR LINTEL COMPANIES, <br />FURTHER REVIEW BY THE BUILDING ENGINEER IS REQUIRED. <br />TO THE BEST OF MY KNOWLEDGE, THESE PLANS <br />AND SPECIFICATIONS COMPLY WITH THE <br />APPLICABLE MINIMUM BUILDING CODES <br />AND APPLICABLE FIRE SAFETY STANDARDS. <br />ALL WORK SHALL COMPLY WITH PREVAILING REVIEW DATE <br />CODES FLORIDA BUILDING CODE, CITY OF ZEPHYRHIL 1 <br />NATIONAL ELECTRIC CODE, <br />AND THE CITY OF ZEPHYRHILLS PLAN EXAMINER <br />ORDINANCES <br />M <br />N <br />Ld <br />w <br />w <br />J <br />Q <br />0 <br />0 <br />U <br />Of <br />Of <br />W <br />LIj <br />co <br />U <br />LIj <br />U <br />U <br />x <br />U <br />cy- <br />Z <br />J <br />V) <br />d <br />Y <br />U <br />a <br />a <br />i <br />N <br />0 <br />N <br />H <br />0 <br />U <br />0 <br />z <br />� <br />Q <br />J <br />� <br />J <br />�c2) <br />U <br />i�L Lj_j <br />U <br />rK U <br />�� <br />171 <br />_j <br />U LLJ <br />Lei LLJ N <br />U Ln <br />Cn <br />LL <br />00 <br />z I U <br />C CL <br />Ll-1 N <br />I <br />O <br />O <br />DATE: 04/05/2021 <br />DRAWN: J.11.5. <br />CHECKED: P.A.S. <br />PROJECT: 2102 <br />SHEET NUMBER <br />AO-00 <br />1 OF 12 <br />