Typical: All Interior
<br />E 1f Doors are 1" Undercut
<br />(Up to 30 CFM - FMC 601.6)
<br />RIM
<br />Air Handler May Be
<br />Re -Configured for
<br />Structure
<br />r Bath
<br />\ I
<br />�3Illy
<br />r r
<br />♦ 1 ►♦♦4e 1 ; I � ..� 11 1 1 1�♦V ►. ♦♦
<br />♦S, ♦♦ ♦ ♦ r♦♦♦♦♦♦♦ ♦ ♦♦♦♦♦♦ ,,
<br />♦ ♦♦s ♦ ♦♦♦♦♦♦♦♦♦ , ♦♦♦1♦♦� ml
<br />B I i
<br />M Bath
<br />C.U.D106Ct♦IECT
<br />------------------- S8,6",74 CFM,Reg:10x6
<br />14
<br />CU-1 rn L n
<br />On Slab
<br />EF-1
<br />VTR
<br />Exterior Roof Surface
<br />Unscreened Roof Cap and Back
<br />Draft Damper.
<br />Fasten to Structure to
<br />Meet up to Wind Maximums.
<br />Engineered Fastening Detail
<br />and Manufacturer's Install
<br />Instructions are Supplied on Site
<br />by the Installing Contractor.
<br />Domestic Style
<br />Range Hood
<br />7", 28ga Galy. Sheet
<br />(<400 CFM)
<br />Metal Duct Vented
<br />FMC 505
<br />to Exterior
<br />Unscreened Wall Cap and Back
<br />Draft Damper.
<br />Fasten to Structure to
<br />Meet up to Wind Maximums.
<br />Engineered Fastening Detail
<br />and Manufacturer's Install
<br />Instructions are Supplied on Site
<br />Domestic Range
<br />by the Installing Contractor.
<br />May also be Down
<br />Flow or Ductless
<br />Exterior Wall/Soffit Surface
<br />vov N.T.S.
<br />Range Exhaust Detail
<br />1 J-X21- 1 LAM
<br />Bed2 C
<br />I `: 616
<br />SB,6",77 CFM,Reg:10x6
<br />RB,6",55 CFM,Grille:12x12
<br />IV
<br />Bed3
<br />SB,6",72 CFM,Reg:10x6
<br />RB,6",50 CFM,Grille:12x12
<br />Exterior Roof Surface
<br />Unscreened Roof Cap and Back
<br />Draft Damper. Fasten to
<br />Structure to Meet up to Wind
<br />Maximums. Engineered Fastening
<br />Detail and Manufacturer's Install
<br />Instructions are Supplied on Site
<br />by the Installing Contractor.
<br />Domestic Style
<br />Clothes Dryer
<br />4" - 28ga Galy. Sheet Metal Duct
<br />(<200 CFM)
<br />Review Compliance for Developed Length.
<br />FMC 504
<br />Vent to Exterior Wall or Roof.
<br />Provide Wall Box or Via Dryer
<br />Installation Instructions.
<br />Unscreened Wall Cap and Back
<br />Draft Damper.
<br />Fasten to Structure to
<br />Meet up to Wind Maximums.
<br />Engineered Fastening Detail
<br />and Manufacturer's Install
<br />Flexible Transition Instructions are Supplied on Site
<br />Duct Connection
<br />by the Installing Contractor.
<br />by Other(s)
<br />- .
<br />Exterior Wall/Soffit Surface
<br />r�oo N.T.S.
<br />Dryer Exhaust Detail
<br />T
<br />1 1
<br />SB,7",143 CFM,Reg:10x10 SB,7",143 CFM,Reg:10x10
<br />Living
<br />Exterior Roof Surface
<br />Screened Roof Cap
<br />Fasten to Structure for
<br />up to 200 MPH Wind Maximums.
<br />Engineered Fastening Detail
<br />and Manufacturer's Install
<br />Instructions are Supplied on Site
<br />by the Installing Contractor.
<br />y
<br />.001
<br />General Exhaust Duct Vent
<br />to Exterior: Wall or Roof.
<br />Ceiling Exhaust
<br />FMC 501, 601 & 603
<br />Fan Vented to
<br />Building Exterior
<br />FMC 501
<br />Screened Wall Cap
<br />Fasten to Structure for
<br />up to 200 MPH Wind Maximums.
<br />Engineered Fastening Detail
<br />and Manufacturer's Install
<br />Instructions are Supplied on Site
<br />by the Installing Contractor.
<br />Integral
<br />Backdraft
<br />Damper
<br />Exterior Wall/Soffit Surface
<br />07W N.T.S.
<br />Exhaust Fan Detail
<br />rn
<br />FRONT PORCH
<br />VAI CL6.
<br />v1
<br />,I
<br />+it
<br />I
<br />Jt'I
<br />Exterior Roof Surface
<br />Screened Roof Cap
<br />Fasten to Structure to
<br />Meet up to Wind Maximums.
<br />Engineered Fastening Detail
<br />and Manufacturer's Install
<br />Instructions are Supplied on Site
<br />by the Installing Contractor.
<br />Ventilation Air Duct
<br />Connects to Return
<br />Building Ventilation Air Duct
<br />Air Plenum Duct and
<br />Exterior Approved Location
<br />Motorized Ventilation Air
<br />koTo
<br />Damper.
<br />Interlocked with
<br />Indoor Air Fan Motor.
<br />Screened Wall Cap
<br />Fasten to Structure to
<br />Meet up to Wind Maximums.
<br />Engineered Fastening Detail
<br />and Manufacturer's Install
<br />Instructions are Supplied on Site
<br />by the Installing Contractor.
<br />Exterior Wall/Soffit Surface
<br />00% N.T.S.
<br />Ventilation Air Detail
<br />Reducer Box
<br />Trunk andBranch
<br />W2
<br />Sizes shown on
<br />HVAC Drawing
<br />H
<br />�.
<br />y.
<br />Arrow(s)
<br />Indicate
<br />Airflow
<br />-
<br />Direction
<br />W
<br />W
<br />1k Modify To Fit Structure L
<br />Trunk to Branch Junction Box
<br />Cap Size Equals Outlet
<br />Construct, Seal and Suspend from Structurc
<br />Trunk Duct Size plus 2"
<br />FMC 601, 602, 603 & 604
<br />Truct
<br />Duct
<br />Size
<br />DIMENSIONS
<br />- INCHES
<br />W
<br />H
<br />L
<br />W2
<br />6 - 12
<br />13
<br />13
<br />18
<br />14,16
<br />17
<br />17
<br />18
<br />118,20
<br />1 21
<br />1 21
<br />1 18
<br />Tri-Box
<br />H
<br />�i
<br />/ L
<br />Truct
<br />Duct
<br />Size
<br />W
<br />I H
<br />L
<br />6 - 12
<br />13
<br />13
<br />18
<br />14,16
<br />17
<br />17
<br />18
<br />18,201
<br />21
<br />21
<br />1 18
<br />I r��v N.T.S.I Flex Duct Junction Box Detail
<br />Supply/Return Air Duct
<br />Trunk or Flex Junction
<br />Box Construct; Seal and
<br />Suspend from Structure.
<br />FMC 601, 603 & 604
<br />Installing Contractor
<br />may use this Secondary
<br />*Optional* Volume
<br />Damper; Provide Access
<br />for Adjustment. 4
<br />FMC 603.18
<br />Ceiling Register Box
<br />Fasten to Structure with
<br />Register Box Rails. May
<br />Mount Floor, Wall or Ceiling
<br />Structure. Air Device Type
<br />may Vary from Shown.
<br />FMC 601, 603 & 604
<br />Install Flex Duct with 45
<br />Degree Elbows near the
<br />Trunk and Boot Connections.
<br />Allow 6" Min. Straight Duct
<br />at Boot and Trunk Connections.
<br />Duct Bends Shall Maintain a
<br />Center Line Radius of not Less
<br />than One Duct Diameter.
<br />Use U1181 Class 1
<br />FMC 601, 603 & 604
<br />Fasten Register or
<br />Grille to Register
<br />Box. May Mount
<br />Floor, Wall or
<br />Ceiling.
<br />Provide Primary
<br />• Volume Damper
<br />and Adjustable
<br />Curve Blades.
<br />FMC 603.18 & 604
<br />I0,01 N.T.S] Ductboard / Flex Duct Detail
<br />Ventilation Air Duct. Supply Air Plenum
<br />=--_- Mechanically Fasten
<br />See Ventilation Air
<br />Detail Note. to Equipment Flange.
<br />FMC 401
<br />ot FMC 601, 602, 603 & 604
<br />Air Handling Unit
<br />FMC 303, 304 & 306
<br />Return Air Plenum
<br />Mechanically Fasten to
<br />Equipment Flange 0 High Voltage
<br />May Mount Either Side Disconnect Switch
<br />or Rear of Air Handler.
<br />FMC 601, 602, 603 & 604
<br />Refrigerant Piping and Control
<br />Wiring
<br />FMC 305 & 1107
<br />Primary Condensate Drain Line, -`
<br />Route to Exterior, Dischare 12" Equipment Platform
<br />from Building Lined with Ductboard.
<br />FMC 305 & 307 Free Area Equal to
<br />Duct Flange Connection
<br />6" Above Finished Floor
<br />Water Detection Device
<br />FMC 307.2.3.1 Floor Wall
<br />N.T.S. Vertical Air Handler and Riser Detail
<br />Exterior Condensing Unit FMC 303, 304 & 306 Typical Pipe Cover
<br />B Wall g Fasten, May Mount Interior
<br />High Voltage
<br />— Disconnect
<br />Switch
<br />i
<br />Equipment Tie IIII�III
<br />Down II I Refrigerant Piping
<br />Engineered Fastening and Control Wire
<br />Detail and I Routing may Vary
<br />Manufacturer's IIIIII FMC 305 & 1107
<br />Installation Instructions IIIII
<br />Supplied on Site by IIIIII
<br />Installing Contractor I�
<br />P 4" Thick Concrete Slab
<br />or Code Approved Equal
<br />FMC 303 & 304
<br />Grade 3" Below Slab
<br />N.T.S. Condenser / Slab Detail
<br />E
<br />>+ C
<br />V
<br />'p cm
<br />C
<br />a� 0 0
<br />CO
<br />0 ip
<br />O
<br />~
<br />0 0
<br />E U >,
<br />0
<br />10
<br />'0 10
<br />d 4)V
<br />00
<br />fn 0 to
<br />>. W
<br />NUS
<br />imco
<br />End
<br />Q
<br />= W
<br />�
<br />3
<br />C
<br />E
<br />O
<br />C
<br />C
<br />tC
<br />CL
<br />0
<br />Cn
<br />> E E O O
<br />= 0 M V
<br />U Z M _I (n
<br />�— 5'- 0" --
<br />SCALE 1/4"=1'-0"
<br />36"x24" ARCH D
<br />Print these Documents in
<br />CO OR
<br />TF
<br />PIA
<br />CM
<br />Ct
<br />r
<br />oo
<br />0
<br />(,O
<br />00
<br />00
<br />OO
<br />00
<br />r-
<br />O
<br />r
<br />O
<br />co
<br />99
<br />M
<br />NNLJL
<br />0
<br />0
<br />CM
<br />T
<br />r
<br />T •NCM
<br />r i
<br />C�
<br />C
<br />V
<br />U a00
<br />N
<br />M
<br />M O
<br />R' o
<br />a[LNT-
<br />X
<br />iriaI-":ai
<br />N
<br />Q
<br />Z=
<br />UJ
<br />. Q
<br />0_J
<br />V
<br />0 F_
<br />U) U
<br />t;14
<br />LLJQF-
<br />3
<br />00Lu00
<br />F- IV
<br />LULU
<br />Z Z
<br />M
<br />-7 00
<br />F. N
<br />0
<br />LLJ
<br />FF_
<br />aapa
<br />U2
<br />U
<br />Orientation
<br />North
<br />PERMIT SET
<br />DRAWING DATE
<br />3/29/2021
<br />HVAC
<br />DRAWING
<br />20F3
<br />
|