Laserfiche WebLink
Typical: All Interior <br />E 1f Doors are 1" Undercut <br />(Up to 30 CFM - FMC 601.6) <br />RIM <br />Air Handler May Be <br />Re -Configured for <br />Structure <br />r Bath <br />\ I <br />�3Illy <br />r r <br />♦ 1 ►♦♦4e 1 ; I � ..� 11 1 1 1�♦V ►. ♦♦ <br />♦S, ♦♦ ♦ ♦ r♦♦♦♦♦♦♦ ♦ ♦♦♦♦♦♦ ,, <br />♦ ♦♦s ♦ ♦♦♦♦♦♦♦♦♦ , ♦♦♦1♦♦� ml <br />B I i <br />M Bath <br />C.U.D106Ct♦IECT <br />------------------- S8,6",74 CFM,Reg:10x6 <br />14 <br />CU-1 rn L n <br />On Slab <br />EF-1 <br />VTR <br />Exterior Roof Surface <br />Unscreened Roof Cap and Back <br />Draft Damper. <br />Fasten to Structure to <br />Meet up to Wind Maximums. <br />Engineered Fastening Detail <br />and Manufacturer's Install <br />Instructions are Supplied on Site <br />by the Installing Contractor. <br />Domestic Style <br />Range Hood <br />7", 28ga Galy. Sheet <br />(<400 CFM) <br />Metal Duct Vented <br />FMC 505 <br />to Exterior <br />Unscreened Wall Cap and Back <br />Draft Damper. <br />Fasten to Structure to <br />Meet up to Wind Maximums. <br />Engineered Fastening Detail <br />and Manufacturer's Install <br />Instructions are Supplied on Site <br />Domestic Range <br />by the Installing Contractor. <br />May also be Down <br />Flow or Ductless <br />Exterior Wall/Soffit Surface <br />vov N.T.S. <br />Range Exhaust Detail <br />1 J-X21- 1 LAM <br />Bed2 C <br />I `: 616 <br />SB,6",77 CFM,Reg:10x6 <br />RB,6",55 CFM,Grille:12x12 <br />IV <br />Bed3 <br />SB,6",72 CFM,Reg:10x6 <br />RB,6",50 CFM,Grille:12x12 <br />Exterior Roof Surface <br />Unscreened Roof Cap and Back <br />Draft Damper. Fasten to <br />Structure to Meet up to Wind <br />Maximums. Engineered Fastening <br />Detail and Manufacturer's Install <br />Instructions are Supplied on Site <br />by the Installing Contractor. <br />Domestic Style <br />Clothes Dryer <br />4" - 28ga Galy. Sheet Metal Duct <br />(<200 CFM) <br />Review Compliance for Developed Length. <br />FMC 504 <br />Vent to Exterior Wall or Roof. <br />Provide Wall Box or Via Dryer <br />Installation Instructions. <br />Unscreened Wall Cap and Back <br />Draft Damper. <br />Fasten to Structure to <br />Meet up to Wind Maximums. <br />Engineered Fastening Detail <br />and Manufacturer's Install <br />Flexible Transition Instructions are Supplied on Site <br />Duct Connection <br />by the Installing Contractor. <br />by Other(s) <br />- . <br />Exterior Wall/Soffit Surface <br />r�oo N.T.S. <br />Dryer Exhaust Detail <br />T <br />1 1 <br />SB,7",143 CFM,Reg:10x10 SB,7",143 CFM,Reg:10x10 <br />Living <br />Exterior Roof Surface <br />Screened Roof Cap <br />Fasten to Structure for <br />up to 200 MPH Wind Maximums. <br />Engineered Fastening Detail <br />and Manufacturer's Install <br />Instructions are Supplied on Site <br />by the Installing Contractor. <br />y <br />.001 <br />General Exhaust Duct Vent <br />to Exterior: Wall or Roof. <br />Ceiling Exhaust <br />FMC 501, 601 & 603 <br />Fan Vented to <br />Building Exterior <br />FMC 501 <br />Screened Wall Cap <br />Fasten to Structure for <br />up to 200 MPH Wind Maximums. <br />Engineered Fastening Detail <br />and Manufacturer's Install <br />Instructions are Supplied on Site <br />by the Installing Contractor. <br />Integral <br />Backdraft <br />Damper <br />Exterior Wall/Soffit Surface <br />07W N.T.S. <br />Exhaust Fan Detail <br />rn <br />FRONT PORCH <br />VAI CL6. <br />v1 <br />,I <br />+it <br />I <br />Jt'I <br />Exterior Roof Surface <br />Screened Roof Cap <br />Fasten to Structure to <br />Meet up to Wind Maximums. <br />Engineered Fastening Detail <br />and Manufacturer's Install <br />Instructions are Supplied on Site <br />by the Installing Contractor. <br />Ventilation Air Duct <br />Connects to Return <br />Building Ventilation Air Duct <br />Air Plenum Duct and <br />Exterior Approved Location <br />Motorized Ventilation Air <br />koTo <br />Damper. <br />Interlocked with <br />Indoor Air Fan Motor. <br />Screened Wall Cap <br />Fasten to Structure to <br />Meet up to Wind Maximums. <br />Engineered Fastening Detail <br />and Manufacturer's Install <br />Instructions are Supplied on Site <br />by the Installing Contractor. <br />Exterior Wall/Soffit Surface <br />00% N.T.S. <br />Ventilation Air Detail <br />Reducer Box <br />Trunk andBranch <br />W2 <br />Sizes shown on <br />HVAC Drawing <br />H <br />�. <br />y. <br />Arrow(s) <br />Indicate <br />Airflow <br />- <br />Direction <br />W <br />W <br />1k Modify To Fit Structure L <br />Trunk to Branch Junction Box <br />Cap Size Equals Outlet <br />Construct, Seal and Suspend from Structurc <br />Trunk Duct Size plus 2" <br />FMC 601, 602, 603 & 604 <br />Truct <br />Duct <br />Size <br />DIMENSIONS <br />- INCHES <br />W <br />H <br />L <br />W2 <br />6 - 12 <br />13 <br />13 <br />18 <br />14,16 <br />17 <br />17 <br />18 <br />118,20 <br />1 21 <br />1 21 <br />1 18 <br />Tri-Box <br />H <br />�i <br />/ L <br />Truct <br />Duct <br />Size <br />W <br />I H <br />L <br />6 - 12 <br />13 <br />13 <br />18 <br />14,16 <br />17 <br />17 <br />18 <br />18,201 <br />21 <br />21 <br />1 18 <br />I r��v N.T.S.I Flex Duct Junction Box Detail <br />Supply/Return Air Duct <br />Trunk or Flex Junction <br />Box Construct; Seal and <br />Suspend from Structure. <br />FMC 601, 603 & 604 <br />Installing Contractor <br />may use this Secondary <br />*Optional* Volume <br />Damper; Provide Access <br />for Adjustment. 4 <br />FMC 603.18 <br />Ceiling Register Box <br />Fasten to Structure with <br />Register Box Rails. May <br />Mount Floor, Wall or Ceiling <br />Structure. Air Device Type <br />may Vary from Shown. <br />FMC 601, 603 & 604 <br />Install Flex Duct with 45 <br />Degree Elbows near the <br />Trunk and Boot Connections. <br />Allow 6" Min. Straight Duct <br />at Boot and Trunk Connections. <br />Duct Bends Shall Maintain a <br />Center Line Radius of not Less <br />than One Duct Diameter. <br />Use U1181 Class 1 <br />FMC 601, 603 & 604 <br />Fasten Register or <br />Grille to Register <br />Box. May Mount <br />Floor, Wall or <br />Ceiling. <br />Provide Primary <br />• Volume Damper <br />and Adjustable <br />Curve Blades. <br />FMC 603.18 & 604 <br />I0,01 N.T.S] Ductboard / Flex Duct Detail <br />Ventilation Air Duct. Supply Air Plenum <br />=--_- Mechanically Fasten <br />See Ventilation Air <br />Detail Note. to Equipment Flange. <br />FMC 401 <br />ot FMC 601, 602, 603 & 604 <br />Air Handling Unit <br />FMC 303, 304 & 306 <br />Return Air Plenum <br />Mechanically Fasten to <br />Equipment Flange 0 High Voltage <br />May Mount Either Side Disconnect Switch <br />or Rear of Air Handler. <br />FMC 601, 602, 603 & 604 <br />Refrigerant Piping and Control <br />Wiring <br />FMC 305 & 1107 <br />Primary Condensate Drain Line, -` <br />Route to Exterior, Dischare 12" Equipment Platform <br />from Building Lined with Ductboard. <br />FMC 305 & 307 Free Area Equal to <br />Duct Flange Connection <br />6" Above Finished Floor <br />Water Detection Device <br />FMC 307.2.3.1 Floor Wall <br />N.T.S. Vertical Air Handler and Riser Detail <br />Exterior Condensing Unit FMC 303, 304 & 306 Typical Pipe Cover <br />B Wall g Fasten, May Mount Interior <br />High Voltage <br />— Disconnect <br />Switch <br />i <br />Equipment Tie IIII�III <br />Down II I Refrigerant Piping <br />Engineered Fastening and Control Wire <br />Detail and I Routing may Vary <br />Manufacturer's IIIIII FMC 305 & 1107 <br />Installation Instructions IIIII <br />Supplied on Site by IIIIII <br />Installing Contractor I� <br />P 4" Thick Concrete Slab <br />or Code Approved Equal <br />FMC 303 & 304 <br />Grade 3" Below Slab <br />N.T.S. Condenser / Slab Detail <br />E <br />>+ C <br />V <br />'p cm <br />C <br />a� 0 0 <br />CO <br />0 ip <br />O <br />~ <br />0 0 <br />E U >, <br />0 <br />10 <br />'0 10 <br />d 4)V <br />00 <br />fn 0 to <br />>. W <br />NUS <br />imco <br />End <br />Q <br />= W <br />� <br />3 <br />C <br />E <br />O <br />C <br />C <br />tC <br />CL <br />0 <br />Cn <br />> E E O O <br />= 0 M V <br />U Z M _I (n <br />�— 5'- 0" -- <br />SCALE 1/4"=1'-0" <br />36"x24" ARCH D <br />Print these Documents in <br />CO OR <br />TF <br />PIA <br />CM <br />Ct <br />r <br />oo <br />0 <br />(,O <br />00 <br />00 <br />OO <br />00 <br />r- <br />O <br />r <br />O <br />co <br />99 <br />M <br />NNLJL <br />0 <br />0 <br />CM <br />T <br />r <br />T •NCM <br />r i <br />C� <br />C <br />V <br />U a00 <br />N <br />M <br />M O <br />R' o <br />a[LNT- <br />X <br />iriaI-":ai <br />N <br />Q <br />Z= <br />UJ <br />. Q <br />0_J <br />V <br />0 F_ <br />U) U <br />t;14 <br />LLJQF- <br />3 <br />00Lu00 <br />F- IV <br />LULU <br />Z Z <br />M <br />-7 00 <br />F. N <br />0 <br />LLJ <br />FF_ <br />aapa <br />U2 <br />U <br />Orientation <br />North <br />PERMIT SET <br />DRAWING DATE <br />3/29/2021 <br />HVAC <br />DRAWING <br />20F3 <br />