My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5777 18th St
Zephyrhills
>
Building Department
>
Building Plans
>
5777 18th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:13:54 PM
Creation date
2/19/2025 8:51:17 AM
Metadata
Fields
Template:
Building Plans
Street #
5777
Location
18th St
Contractor
Southeast Building
Building Plans - Permit #
1977
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pre -Cale Exposure Diagram for Input Data Required on Room -by -Room Heat Load Calculations that Quantifies the HVAC Demands; May Also be Used for Floor Plans with Identical Envelope Components. NOT TO SCALE <br />BUILDING EXPOSURE AND KEY COMPONENTS <br />_ Exterior Wall Interior Wall Knee Wall Gable -End Orientation ® Air Handler Location ® Vent: Exhaust <br />® Partition Wall I Ceiling/Roof Break Wall Floor Exposure 20S Conditioned Area Condenser Location Vent: Dryer/Range <br />0 Return Air Devices) Supply Air Device(s) 776 3 Fenestration: WxH 12�6p Overhangs & Offsets ® Ground Reflection Other: Specific <br />I -iA• <br />Wall 16%, <br />Glass 18% <br />b'bhole Building <br />M <br />Roof 9%. AED Excursion 21/0 <br />Ventilation 13% <br />People 9%I <br />Ductwork 23% <br />Equipment 1 1 % <br />Rotation Front Door Supply Sensible Latent Recommended <br />Degrees Faces CFP41 Gain Gain Tons <br />00 <br />Northeast <br />450 <br />East <br />901, <br />Southeast <br />135" <br />South <br />1800 <br />Southwest <br />2250 <br />West <br />2700 <br />Northwest <br />3150 <br />North <br />* Indicates highest value of all rotations. <br />764 <br />19,762 <br />4,671 <br />2.17 <br />648 <br />17,207 <br />4.667 <br />1.89 <br />764 <br />19,760 <br />4,665 <br />2.17 <br />760 <br />19,669 <br />4,672 <br />2.16 <br />774 <br />19,997 <br />41667 <br />2.19 <br />666 <br />17,603 <br />49664 <br />1.93 <br />*775 <br />*20,011 <br />*4,673 <br />*2.19 <br />760 <br />19,669 <br />41672 <br />2.16 <br />i <br />t <br />Building Rotation Hourly Net Gain <br />8 am 8 am 10 am 11 am 12 pm 1 pm 2 pm 3 pm 4 pm 5 pm 6 pm 7 pm <br />Time of D a y <br />-ttr- Froat Doorfacgs Northeast <br />Educational Heat Load Exposure Diagram <br />FECC Attached Garage <br />FECC Conditioned Building <br />FECC Appliances <br />FECC HVAC Duct Systems <br />Length <br />N/A <br />Avg. Wall Ht. <br />9.3938 <br />Allowances <br />SYSTEM # <br />1 <br />2 <br />3 <br />4 <br />Width <br />Living S.F. <br />1483 <br />BTU Daily <br />BTUH Avg. <br />GMDD T.S.P. <br />.432 <br />Perimeter <br />Volume <br />13931 <br />65,507 <br />2729 <br />Duct S.F. S/A <br />310.6 <br />Height <br /># Bedrooms <br />3 <br />195 <br />12,312 <br />Duct S.F. R/A <br />197.7 <br />Area S.F. <br />Infiltration CFM <br />37 <br />Ventilation CFM <br />60 <br />R/A Grilles # <br />4 <br />MJ8 Design City <br />ODT <br />Juris. # <br />Permit Office <br />(Folio / Lot / Other) <br />Construction Type <br />Zephyrhills, Florida <br />91 <br />611600 <br />Zephyrhills <br />1.00 <br />New Single Family <br />Variable Capacity HVAC Equipment Lootional <br />For Energy Code Minimum Efficient Equipment See HVAC Page 1 <br />Do Not Use Single Stage, Oversized Equipment. <br />HVAC Equipment Shown is for Variable Capacity Selected in Compliance with Manual S and the Florida Energy Conservation <br />Code <br />Section R403.7.1.3, <br />The Lowest Stage of the Variable Capacity Equipment Can Not Be Oversized by More Than 15%of the Demand Calculations <br />Performed at Design Conditions. <br />HVAC Contractor Must Use Manual D Duct Design to Adjust the Duct System for the Increased Airflow Capacity of Upgraded <br />Equipment. <br />This Equipment Contains a Super Highly Efficient Condensing Unit Capable of Adjusting the Equipment Capacity to Neutralize <br />Demands Beyond the Code Minimum HVAC System Design. Select this Variable Capacity Equipment for Homes that have <br />Adequate Exposure Diversity Excursions Greater than 50%, View Manual J AED Report for Calculated Excursion Percentage. <br />Optional Ventilating Dehumidification Equipment may also be Used. To Neutralize the Variable Building Demands, Variable <br />Equipment Operates Almost Continuously to Provide Enhanced Dehumidification, Filtration and Air Circulation. This Equipment <br />Does Not Decouple the Sensible <br />UPGRADE EQUIPMENT SCHEDULE <br />SPLIT SYSTEM HEAT PUMP <br />AIR HANDLER MARK: <br />AHU-1 <br />UNIT MANUFACTURER: <br />AMERICAN STND <br />UNIT MODEL NUMBER: <br />TAM9AOC36 <br />UNIT DIMEN H/Vil <br />56.9x23.5x21.8 <br />UNIT WEIGHT: <br />143 <br />SUPPLY PLENUM SIZE: <br />20.5x14.35 <br />Lu <br />RETURN PLENUM SIZE: <br />20.5x17.15 <br />z <br />a <br />MANUAL D DUCT CFM: <br />1200 <br />= <br />MANUAL D DUCT TSP : <br />CAD / GMDD <br />Q <br />SUPPLY FAN H/P : <br />1/2 <br />BLDG. VENTILATION CFM: 60 <br />MECHANICAL <br />BLDG. INFILTRATION CFM: 37 <br />NATURAL <br />UNIT PHASE / HERTZ: <br />1/60 <br />UNIT VOLTAGE: <br />208 / 240 <br />HEATER KW: <br />3.6 / 4.8 <br />AHU + HEAT MOP: <br />25130 <br />CONDENSER MARK: <br />CU-1 <br />w <br />NOMINAL A/C TONS: <br />3 (25-100%) <br />Z <br />Z <br />UNIT MODEL NUMBER: <br />4A6VO036 <br />p <br />UNIT VOLTAGE: <br />208/230/ 1 / 60 <br />p <br />UNIT MCA / MOP: <br />26 / 40 <br />rJ <br />UNIT DIMEN H/W/D: <br />41x37x35 <br />UNIT WEIGHT: <br />254 <br />COOL / OUTDOOR TEMP: <br />91 <br />92 <br />93 <br />N <br />TOTAL COOLING KBTUH: <br />36.6 <br />36.4 <br />36.3 <br />Q <br />SENS. COOLING MAX KBTUH: <br />28.8 <br />28.7 <br />28.6 <br />Z <br />SENS. COOLING MIN KBTUH: <br />7.2 <br />7.2 <br />7.2 <br />g <br />LAT. COOLING MAX KBTUH: <br />7.8 <br />7.7 <br />7.7 <br />SENSIBLE HEAT RATIO: <br />0.79 <br />0.79 <br />0.79 <br />TOTAL HEATING KBTUH: <br />33.4 <br />SEER / HSPF: <br />19.75 / 10 <br />= <br />95/75at75%SHR:TC,SC,LC <br />35.0 26.3 1 8.7 <br />a <br />CERT. REFERENCE #: <br />10093448 <br />THERMOSTAT MODEL: <br />PROGRAM <br />ALTERNATE BRAND EQUIPMENT CAPABLE OF <br />NEUTRALIZING BOTH LATENT AND SENSIBLE <br />w <br />DEMAND'S IS ACCEPTABLE SEE MANUAL J. <br />p <br />VIEW ENERGY FORMS FOR MIN. EFFICIENCIES. <br />Z <br />HVAC CONTRACTOR TO PROVIDE EQUIPMENT <br />a <br />CC <br />TIE DOWN AND INSTALL INSTRUCTIONS + <br />Lu <br />w <br />MATCHED EQUIPMENT AHRI RATINGS ON <br />SITE FOR FIELD INSPECTORS APPROVAL. <br />INFORMATION SHOWN ABOVE IS SUBJECT TO <br />CHANGE / SITE VERIFY EQUIP. DATA PLATE. <br />LOW / HIGH FAN CAPACITY ADJ. (.98 / 1.02) <br />Duct Zoning Control System I Optional <br />Thermal Zone Dampers --- <br />//��. /�`� /U✓�//,.,; �y�}✓///) Air Handling Unit <br />Bypass Air Duct Return Air <br />-- T <br />------ Thermal Zones <br />This Option is Designed in Accordance with Manual ZR HVAC Zone Design. <br />Zoning Provides Multiple Thermostat Controllers on a Single HVAC System, Controlled by a <br />Control Panel. <br />This Option is Recommended for Every Building Owner who Requires Better Temperature Control, <br />a Lower Operating Cost, Lower Upfront HVAC Cost when Compared to Multiple HVAC Systems. <br />Zoning Provides the Ability to Meet the Thermal Zone Peak Hour Load and for Buildings that Don't have <br />Adequate <br />Exposure Diversity. <br />This Zone Control System is a Minimum Requirement when Serving more than One Level of a <br />Building from a Single HVAC System, for Buildings that have Variable Occupancies or Variable <br />Usage and Occupants who Prefer Different Temperatures Throughout the Building. <br />HVAC Zone Control Systems Can Easily be Added to a Standard "Code Minimum" HVAC System, <br />Providing Up To 30 Thermostats per HVAC System. <br />Zone Control Panels Monitor Each Thermal Zone Temperature and Provides Conditioned Air to <br />Each Thermal Zone of the Building if and When Needed. <br />HVAC Installer Must Install the System in Accordance with Manual ZR. <br />High Efficient Air Filtration I Optional <br />This Option Provides Cleaner Indoor Air Using a 5" Thick Mery 13 Hepa Filter Added To The Standard <br />"Code Minimum" HVAC System. This High Performance Particle Arrestance Filter can Capture Much <br />More and Much Smaller Size Contamination than the Standard 1" Thick Air Filter. Hepa Filters can <br />Better Protect the HVAC Air Handler Coil from Dust and Debris. and Requires Less Maintenance, as <br />Most Buildings Require Just a Yearly Filter Change. <br />When Using a Bipolar Ionization Systems, Use this Option. <br />Dedicated Dehumidification I Optional <br />Air Handling Unit <br />rw <br />Dehumidifier <br />q <br />i <br />Dehumidifier <br />kQlpw <br />Sealed Attic <br />This Option is a Must for Buildings that Require Controlled Year Round Dehumidification and is Recommended for <br />All Buildings in the Southeastern United States. <br />This Dedicated Equipment can be Added to the Standard "Code Minimum" HVAC Duct System for Whole Building <br />Dehumidification within the Conditioned Space. Install the Wall Mounted Dehumidistat in the Conditioned Space <br />Near the Main Thermostat. <br />This Equipment can also be Installed in an Unvented Attic Space with Intake Ducts Mounted High at the Attic Roof <br />Peak; Use a Peak Mounted Dehumidistat for Control. <br />Select a Ventilating Dehumidification System for Buildings that Require Interior Pressurization, Provide Equal <br />Amount of Relief Air from the Building's Conditioned Space. Note that Both the Standard "Code Minimum" <br />Equipment Selection and the Optional Staged Capacity Equipment Selection do not Provide Controlled <br />Year -Round Dehumidification Because the Latent Heat Removal Process is Coupled with the Cooling Cycle on <br />Typical HVAC Equipment. <br />Controlling Moisture Requires Equipment that Monitors and Removes Moisture Without Cooling the Interior <br />Space. <br />Bipolar Ionization System I Optional <br />This Option Provides Both Negative and Positive Oxygen Ions that Neutralize Airborne Pollutants. <br />Used Mery 13 Filter, this Option Uses a Gas Phase Disassociation Process Resulting in Cleaner and <br />Healthier Indoor Air. Reduction of Smoke, Dust, Pollen, Bacteria, Viruses, VOC Gases, Mold Spores and <br />Odors. <br />These Electronic Units Use Very Little Electricity and Mount in the Duct Air Stream. <br />Plasma lar Model PA600 for Residential Use. <br />Germicidal Air Handling Treatment Optional <br />Typical Vertical Air Handler Shown <br />Horizontal Air Handler Similar <br />1 <br />This Option Provides Ultraviolet Light System(s) that Kill Airborne and Surface <br />Microorganism Contaminants like Mold and Bacteria. <br />www.Freshaireuv.com <br />Model TUV-200Q-I, 4 Light Shown Mounts in the Air Handler for Full Coil Coverage. <br />NOTE: This Drawing Page is Not a Code Requirement. <br />Drawing Page Shows the Demand Calculations Based on an Exposure Diagram for the <br />Thermal Envelope, Input Data and Additional Options and Upgrades that Could be Added <br />to the Code Minimum HVAC System Design. <br />E <br />r, <br />O <br />C i <br />O <br />5 00 <br />Mtn <br />o <br />0 <br />Z <br />O o0 <br />G) -0 <br />O CM <br />N O M <br />>, (D <br />NUcc <br />moo <br />atm <br />a <br />3: <br />=w <br />3 <br />O <br />r.+ <br />t4 <br />E <br />1111 <br />CL <br />E <br />O <br />it3 _ <br />> EE �_ c- <br />_ R U ON <br />O M <br />U Z in � cn <br />5'- 0" <br />SCALE 1/4"=V-0" <br />36"x24" ARCH D <br />Print these Documents in <br />CO OR <br />W <br />Z <br />M <br />00 <br />TT <br />TT <br />oo <br />00 <br />00 <br />66 <br />O O <br />M M <br />r � <br />O O <br />r r � <br />CD <br />Cl <br />O O M <br />C CV U__ <br />W co <br />N N N <br />T T ci <br />T r <br />a @ 7@QCN <br />a0-N <br />cri a: � U, <br />QW N L4. Q <br />ZHcc J <br />-cch0 <br />V�Upcv <br />Q <br />W F- W W <br />) 0 Z Z <br />OUWOO <br />a � ON <br />W <br />0aZa <br />a <br />O� <br />U <br />Orientation <br />North <br />PERMIT SET <br />DRAWING DATE <br />3/29/2021 <br />HVAC <br />DRAWING <br />30F3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.