My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5967 14th St
Zephyrhills
>
Building Department
>
Building Plans
>
5967 14th St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 1:02:08 AM
Creation date
2/19/2025 8:51:38 AM
Metadata
Fields
Template:
Building Plans
Street #
5967
Location
14th St
Contractor
Butterfield Investments
Building Plans - Permit #
909
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
b <br />V <br />F. <br />I <br />Ln <br />3' _ 4„ <br />( 2) SH25 <br />EGRESS <br />18'-8" <br />2' <br />SH23 <br />3 0'- <br />r11] <br />AREA'S <br />LIVING <br />GARAGE <br />COVERED <br />COVERED <br />FRONT PORCH <br />BACK PORCH <br />TOTAL AREA UNDER ROOF <br />1ST FLOOR CEILING HEIGHT 8' <br />UNLESS NOTED <br />1609 <br />465 <br />30 <br />68 <br />2172 S.F. <br />hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition <br />David W. Smith, P.E. #53608 <br />THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS UPON THE INTERACTION OF VARIOUS <br />CONNECTED COMPONENTS. PROVIDE ADEQUATE BRACING, SHORING AND ANY OTHER TEMPORARY SUPPORTS <br />AS REQUIRED TO SAFELY COMPLETE THE WORK. <br />ALL WINDOWS AND DOORS SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS <br />TO RESIST THE WIND LOADS INDICATED AND TO MEET OTHER CODE REQUIREMENTS FOR <br />AIR AND WATER INTRUSION. FOR BUILD—UP DOORS, WINDOWS OR ACCESSORIES <br />PERMANENTLY ATTACHED THROUGH THE BODY OF THE MATERIAL BEING FASTENED USE <br />#10 WOOD SCREWS PENETRATING INTO THE ROUGH FRAMING MENBER AT LEAST 2" @ 12" <br />ON CENTER, OR MASONRY ATTACHMENTS USE 3/16" X 1" EMBEDMENT "TITAN" OR "TAPCON" <br />HEX HEAD MASONRY ANCHORS @ 12" ON CENTER. <br />WINDOW AND DOOR MANUFACTURERS TO PROVIDE CERTIFICATION/RATING THAT THEIR WINDOWS AND DOORS <br />WILL WITHSTAND THE PRESSURE RESULTING FROM THE SPECIFIED DESIGN COMPONENTS AND CLADDING WIND <br />PRESSURE AND PROVIDE INSTALLATION INFORMATION WITH THEIR PRODUCTS. <br />CONTRACTOR TO INSTALL WINDOWS AND DOORS ACCORDING TO INSTRUCTIONS SUPPLIED BY MFGR AND HAVE <br />MANUFACTURERS SPECIFICATIONS (CUT SHEETS) ON SITE AT THE TIME OF INSPECTION FOR REVIEW BY THE <br />BUILDING INSPECTOR. <br />ALL DOORS INTERIOR & EXTERIOR ARE 6'-8" UNLESS OTHERWISE NOTED <br />PROVIDE TEMPERED GLAZING IN ACCORDANCE WITH FBC FOR GLAZED, SLIDING, FIXED AND <br />SWING DOORS. ALSO SHOWER ENCLOSURES AND ALL GLAZING WITH 24" OF ALL DOORS. ALL <br />GLAZING 9.0 SQ FT OR GREATER, OR LESS THAN 18" A.F.F. SHALL BE TEMPERED. (FBC R308.4) <br />ALL EGRESS WINDOWS FROM SLEEPING ROOMS SHALL HAVE A MINIMUM CLEAR OPENING <br />OF 5.7 SQ. FT. (MIN OPENING SIZES = 2'-0" X V-8", SILL @ 44" A.F.F. MAX) <br />ALL HURRICANE CLIPS, STRAPS AND FASTENERS ARE TO BE APPLIED ACCORDING TO THE FASTENERS <br />SCHEDULE AND MANUFACTURERS SPECIFICATIONS. IF DESIRED, EQUALVENT CONNECTORS MADE BY ANOTHER <br />SUPPLIER MAY BE USED IN PLACE OF THE CONNECTORS SHOWN. <br />HURRICAN CLIPS ARE REQUIRED ON ALL TRUSSES AND RAFTERS. IF PLYWOOD OR OSB SHEATHING DOES NOT OVER TOP PLATE, <br />HURRICANE CLIPS MUST BE COVER BOTH TOP PLATES. <br />UPLIFT PROTECTION: PLYWOOD OR OSB COVERING ENTIRE EXTERIOR OF HOME WITH NAILS SPACED 3" O.C. AT TOP AND BOTTOM, <br />6" O.C. ON EDGES AND THE REMAINDER AT 12" O.C. OR PLAYWOOD OR OSB AT CORNERS, WITH HURRICANE STRAPING ON EVERY <br />EXTERIOR STUD, CRIPPLE, JACKSTUD ETC. AT TOP AND BOTTOM. <br />R302.6 DWELLING —GARAGE FIRE SEPARATION <br />THE GARAGE SHALL BE SEPARATED AS REQUIRED BY TABLE R302.6. OPENINGS IN GARAGE WALLS SHALL COMPLY WITH SECTION R302.5. <br />ATTACHMENT OF GYPSUM BOARD SHALL COMPLY WITH TABLE R702.3.5. THE WALL SEPARATION PROVISIONS OF TABLE R302.6 SHALL NOT <br />APPLY TO GARAGE WALLS THAT ARE PERPENDICULAR TO THE ADJACENT DWELLING UNIT WALL. <br />NOT LESS THAN 1/2—INCH GYPSUM BOARD OR EQUIVALENT APPLIED TO THE GARAGE SIDE. <br />GENERAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND COORDINATING ALL FIELD DIMENSIONS. <br />ENGINEER LICENCE #53608 <br />B UTTER FI ELD INVESTMENTS I N C <br />5967 14TH STREET <br />ZEPHYRHILLS, FLORIDA <br />D.W.SMITH,M.S.,P.E.#53608 <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLASTON DRIVE—DADE CITY, FLORIDA 33525 <br />PHONE: 813-469-2289 E-MAIL: dwsf[pe@eo.rthtink.net <br />TERI BUTTERFIELD <br />CDC1332445 <br />RICK GOLLHARDT - DRAFTSMAN <br />813-781-3651 <br />rgollhardt@tampabay. rr. com <br />FLOOR PLAN SHEET OF <br />2 OF 10 <br />SCALE DATE JOB NO, <br />DO NOT SCALE 26 SEPT 2020 <br />DESIGN/DRAWN CHECKED 2020-0831 <br />R. GOLLHARDT D.W.S.,p.e. <br />
The URL can be used to link to this page
Your browser does not support the video tag.