Laserfiche WebLink
Ln <br />30 <br />18'-8" 11'-4" <br />3'— 4" 2' <br />-! <br />® ®------- ®------ ®------® ® 1 ❑ 1 <br />4" CONCRETE SLAB <br />I <br />E2) <br />GRESS 25 SH23 i 2, <br />I <br />DA4TUM <br />I I <br />I i <br />I <br />-----------------------I <br />I I <br />I DATUM 1 <br />o-0 3068 <br />I I <br />I I 00 <br />i I <br />OD <br />I I <br />I I <br />®I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />SH23 <br />I <br />I I <br />20"H X 12"W MONOLITHIC FOOTINGS WITH 2 EACH <br />#5 (5/8) RODS CONTINUOUS ON „CHAIRS -TYPICAL <br />BOTTOM OF FOOTER SHALL BE 12 FROM GRADE <br />I I <br />I I <br />I I <br />® i I <br />I I <br />SH25 1 <br />EGRESS <br />®i 4" CONCRETE 3000PS1 WITH #10 2) SH24 <br />1 6X6 MESH ON �6 MIL POLY <br />VAPOR BARRIER OVER CLEAN 1 <br />COMPACTED POISON TREATED <br />SOIL. VAPOR BARRIOR <br />' MATERIAL TO BE LAPPED 1 <br />6"WITH SEAMS TAPED <br />®; FIBERMESH CAN BE SUBSTITUED <br />i 1 <br />I I <br />I i <br />I I <br />I I <br />I I I <br />I I � <br />I I <br />I I <br />® I I <br />I I <br />I I <br />I 1 <br />I I <br />I I <br />I I <br />I 1 <br />I I <br />I I <br />I 1 <br />I I <br />® I I <br />(2) SH24 <br />SH25 1 <br />EGRESS <br />I <br />I I <br />® I I <br />I 1 <br />1 I <br />I 1 <br />1 I <br />I I <br />®1 I <br />I I <br />DATUM I 00 <br />1 0-o I I <br />I I <br />-------------------------------------------- I® O <br />I I <br />I <br />I I I <br />I I 1 <br />I DATUM I I <br />® 1 -4. 3-0 i 3068 <br />I I 1 <br />1 J-----------J <br />1 000 L <br />» <br />I I I I <br />w j oN i 4" CO ETE SLAB <br />1 O 00 DATUM r-- <br />� \ I -4" 1 I <br />® 1 <br />I 1 <br />I I <br />I 1 <br />I I <br />I � <br />I <br />I I <br />1 I <br />I I <br />I I <br />I 1® <br />®1 I <br />I I <br />I I <br />I I <br />I I <br />I I <br />16' X7' GARAGE DOOR <br />I I <br />I I <br />L--------------------------------T -------- <br />0 SET <br />—,3'— 4" <br />22'-8" <br />30' <br />NOTE: <br />0 INDICATES 1/2 )) X8" J BOLT SPACED 24" O.C. <br />MAX. LOCATED AT EACH SIDE OF ALL WINDOWS <br />AND DOOR OPENINGS. 1 2"X8" WEDGE ANCHORS <br />MAY BE SUBSTITUTED I PLACE OF J BOLTS <br />NOTE. - <br />INDICATES 1—ATEL. <br />REBAR IN FILLED CELL FROM <br />FOOTING TO LOCATED AT EACH SIDE <br />OF ALL WINDOWS AND DOOR OPENINGS <br />6' O.C. MAXIMUM SPACING. SEE DETAIL FOR LOCATIONS <br />� 8RTED <br />REROD IN GROUTED CELL <br />PER PLAN <br />25" DOWEL LAP MINIMUM <br />4" CONCRETE (3000PS1) WITH #10 <br />6X6 MESH ON 6 MIL POLY <br />VAPOR BARRIER OVER CLEAN <br />COMPACTED POISON TREATED <br />SOIL. VAPOR BARRIOR <br />MATERIAL TO BE LAPPED <br />6 WITH SEAMS TAPED <br />FIBERMESH CAN BE SUBSTITUED <br />20"H (X 1))2"W MONOLITHIC FOOTINGS WITH 2 EACH <br />OTT5//0M "OFROFOOTERDS NSHALLUBE012"CFROM GRADEAL <br />TYPICAL MONOLYTHIC <br />FOOTING DETAIL <br />(18�5 REROD IN GROUTED CELL <br />L ATED PER PLAN <br />25" DOWEL LAP MINIMUM <br />4" CONCRETE (3000PS1) WITH #10 <br />6X6 MESH ON 6 MIL POLY <br />w 1. VAPOR BARRIER OVER CLEAN <br />COMPACTED POISON TREATED <br />,ALPORBERIPP> SOIL. <br />LAPPED <br />6 WITH SEAMS TAPED <br />FIBERMESH CAN BE SUBSTITUED <br />CONCRETE TYPE <br />DESIGN ft) <br />MODULES OF <br />ELASTICITY <br />ESIGN (E <br />C-1-P CONCRETE (NORMAL WEIGHT) <br />2,500 Psi <br />2,850 Ksi <br />C4-P CONCRETE (NORMAL WEIGHT) HERNANDO CO. ONLY <br />3,000 PSI <br />3,122 KAI <br />C4-P GROUT <br />3,000 Psi <br />3,122 Kai <br />CONCRETE SHALL CONSIST OF 1" MAXIMUM AGGREGATE CONCRETE MIX WITH SLUMP <br />BETWEEN 6" AND 7" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR ADDITIONAL <br />CRITERIA. <br />GROUT SHALL CONSIST OF PEA ROCK (3/8" MAXIMUM AGGREGATE) CONCRETE MIX <br />WITH SLUMP BETWEEN 8" AND 10" AT TIME OF PLACEMENT. SEE SPECIFICATIONS FOR <br />ADDITIONAL CRITERIA. <br />CONSTRUCTION JOINTS WILL BE PERMITTED <br />METHOD OF CONCRETE FORMING, PLACEMENT AND CURING SHALL BE CONDUCTED IN <br />ACCORDANCE WITH THE SPECIFICATIONS AS STATED. <br />EARTH SUPPORTED SLABS (EXCLUDING EXTERIOR WALKWAYS & DRIVEWAYS) <br />3 1/2" MIN. THICKNESS W MIN. REINFORCEMENT OF 6.0 x 6.0 W/ 1.4 x 1.4 WWF @ <br />MID -DEPTH OF SLAB. FIB RMESH PER DESIGN MIX MAY BE USED I.L.O. WWF @ <br />CONTRACTORS DISCRETION. <br />CONCRETE MASONRY : <br />FILLED CELLS W/ (1) #5 BAR SHALL BE LOCATED PER PLAN. <br />LOAD BEARING COppNNNCCTTRRRETLLELLEEMASONRY BLOCK SHALL BE ASTM C90-0601, TYPE II <br />AOLN �t PnT JRECACVITIESOBELOW GRADE WILL BE FILLED W/ CONCRETE IN ALL <br />STEM WALLS. <br />THE AGGREGATE STRENGTH OF THE BLOCK AND MORTAR SHALL BE F'm = 1,500 PSI <br />MINIMUM. <br />METHOD OF CONCRETE MASONRY PLACEMENT AND CONSTRUCTION SHALL BE <br />CONDUCTED IN ACCORDANCE WITH THE SPECIFICATIONS AS STATED. <br />MORTAR SHALL BE ASTM C270 TYPE "S" FOR ALL MASONRY CONSTRUCTION. <br />SOIL: <br />MINIMUM SOIL BEARING PRESSURE CAPACITY OF 2000 PSF. <br />FOUNDATIONS HAVE BEEN DESIGNED WITH THE MIN. CAPACITY OF 2000 PSF <br />ALL SOIL IS TO BE CLEAN & POISONED FOR TERMITES PER FBC 6th ed. (2017), <br />RESIDENTIAL SECTION R318. <br />4" CON C. SLAB W/ <br />6X6, 1OX10 W.W.M. <br />MONOLITHIC POUR <br />2X4 PT SOLE PLATE: ANCHOR TO FTG <br />W/1 /2DIA X 8 AB @ 24' O.C. OR <br />1/2 WEDGE ANCHOR FOR BARING WALL <br />NON -BEARING TAPCONS @ 24 O.C. <br />4" CONCRETE (3000PSI) WITH #10 <br />6X6 MESH ON 6 MIL POLY <br />VAPOR BARRIER OVER CLEAN <br />COMPACTED POISON TREATED <br />SOIL. VAPOR BARRIOR <br />MATERIAL TO BE LAPPED <br />6"WITH SEAMS TAPED <br />FIBERMESH CAN BE SUBSTITUED <br />GARAGE SLAB : ;'- y = - <br />##20"(W //X 1))2"H STEMWALL FOOTINGS WITH 2 EACH <br />BOTTOM "OF FOOTERNSHALLUBEON <br />2"CFROM GRADE <br />OPTIONAL S TEMWALL <br />FOOTING DETAIL <br />5 VERTICAL WALL REINFORCING <br />ACI 90 STANDARD GROUTED CELL <br />HOOK -EMBED 6" 1 ,BOND BEAM W/(1) #5 REBAR <br />GARAGE <br />FOOTING DETAIL <br />I- J <br />C� <br />= N FILLED CELL <br />O <br />o ' <br />Q <br />w <br />J <br />w 5 DOWEL ACI STANDARD HOOK <br />Ld LQ ' ' IMOED 10" MIN LAP <br />Z 25 MIN W/ VERT. & HORIZ. REINFORCING <br />Ln <br />N , <br />.q..:. �r-��:��CONCRETE FOOTING <br />f . " REINFORCING REBAR <br />(SEE FOUNDATION PLAN) <br />25" MIN LAP <br />MASONRY WALL <br />FILLED CELL DETAIL <br />hereby certify that I have reviewed this plan and found it to be In <br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition <br />David W. Smith, P.E. #53608 <br />WITH <br />#5, (5/8") 'RODSONGS CIONTINUOUS2ONACH CHAIRS -TYPICAL <br />EDGE OF FOOTING <br />z 1 111 1 1 1-#5 DOWEL IN CORNER <br />=0Id <br />25" LAP M I N <br />CORNER DETAIL — FOOTING AND <br />FOUNDATION WALL REINFORCEMENT <br />Vj0N <br />Z, ,p <br />N' 4 <br />ENGINEER LICENCE #53608 <br />TERMITE PREVENTION NOTES: <br />COMPLY WITH FBC 2017 6TH ED. SECTION R318 <br />1. A PERMANENT SIGN WITH IDENTIFIES TREATMENT PROVIDER <br />AND NEED FOR RE-INSP AND TREATMENT RENEWAL SHALL BE <br />PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER <br />ELECTRICAL PANEL FBC 104.26 <br />2. TO ENABLE TERMITE INSPECTION, THE DISTANCE, BETWEEN WALL <br />COVERING AND EARTH GRADE SHALL BE 6 INCHES MINIMUM. <br />EXCEPTION: CORRISION REISITANT METALS, CEMENTATIOUS FINISHES <br />APPLIED DIRECTLY TO FOUNDATION. <br />3. INITIAL TERMITE TREATMENT u ;ALL BE COMPLETED AFTER ALL <br />EXCAVATION AND BACK FILL IS FINISHED. <br />4. SOILD DISTURBED AFTER THE INITIAL TREATENT SHALL BE <br />RE -TREATED, INCLUDING SPACES BOXED OR FORMED. <br />5. BOXED AREAS IN CONCRETE FLOORS AND FOR SUBSEQUENT <br />INSTALLATION OF TRAPS, ETC, SHALL BE MADE IN PERMANENT <br />METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE <br />& DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL <br />AFTER THE TREATMENT. <br />6. MINIMUM 6 MIL POLYFILM MUST BE INSTALLED TO PROTECT <br />AGAINST RAINFALL DILUTION. RETREATMENT IS REQUIRED IF <br />RAINFALL OCCURS BEFORE POLYFILM PLACEMENT. <br />7. CONCRETE OVERPOUR AND MORTOR ALONG THE FOUNDATION <br />PERIMETER MUST BE REMOVED BEFORE EXYERIOR SOIL TREATMENT. <br />8. ALL BUILDINGS ARE REQUIRED TO HAVE PRE —CONSTRUCTION <br />TREATMENT. <br />9. NO WOOD, VEGETATION STUMP, CARDBOARD, TRASH, ETC. SHALL <br />BE BURIED WITHIN 15 FEET OF ANY BUILDING OR PROPOSED <br />BUILDING. <br />10. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST <br />BE REMOVED FROM WITHIN ONE FOOT OF THE BUILDING. THIS <br />INCLUDES <br />ALL <br />GRADE <br />TMATE�IAB. TRAP BOXES, FORMS, OTHER <br />11. A CERTIFICATE OF COMPLIANCE MUST BE PROVIDED TO THE <br />BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY <br />BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE <br />CERTIFICATE OF COMPLIANCE SHALL STATE THE BUILDING HAS <br />RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF <br />SUBTERRANEAN TERMITES AND THAT THE TREATMENT IS IN <br />ACCORDANCE WITH THE RULES AND LAW OF THE FLORIDA DEPT. <br />OF AGRICULTURE AND CONSUMER SERVICE. <br />MISSING ANCHOR BOLTS @ BEARING WALL <br />EXTERIOR BEARING WALL: <br />EXTERIOR BEARING WALL: IN ADDITION TO THE GENERAL <br />PLACEMENT REQUIREMENTS: USE 5(8 DIAMETER X 6" <br />EMBEDMENT BOLTS SPACED A MAX MUM OF 24" O.C. <br />INTERIOR BEARING WALL: <br />IN ADDITION TO THE GENERAL PLACEMENT REQUIREMENTS: USE <br />5/8 DIAMETER X 6" EMBEDMENT BOLTS SPACED A <br />MAXIMUM OF 24" O.C.. IF RESISTING UPLIFT LOADS <br />MISSING DOWELS: <br />IN THE EVENT STEEL HAS BEEN INADVERTEN I L`l OMITTED <br />FROM DOWN POUR LOCATIONS DRILL 5" INTO CONCRETE <br />(NO CLOSER THAT 3 3/4" FROM EDGES AND 5" FROM ENDS <br />OF CAP WALLS), REMOVE DUST PER MFG'S RECOMMENDATIONS <br />AND USE 2 PART EPDXY TO ANCHOR VERTICAL REINFORCEMENT <br />IN PLACE. USE EITHER HILTI C-100 OR SIMPSON EPDXY —TIE. <br />REINFORCING STEEL: <br />REINFORCING STEEL SHALL BE ASTM A615 / A615M-12 MIN. GRADE 40, f'y = 40 Ksi <br />LAP SPLICE SHALL BE AS FOLLOWS: #5 BAR 25", #4 <br />BAR 20", #3 BAR 20". <br />ALL DIMENSIONS PERTAINING TO THE LOCATION OF REINFORCING ARE TO THE <br />CENTERLINE OF EACH BAR EXCEPT WHERE THE COVER <br />DIMENSION IS SHOWN TO THE <br />FACE OF THE CONCRETE. <br />REINFORCING DETAIL DIMENSIONS ARE OUT TO OUT OF <br />BARS. <br />REINFORCING MECHANICAL COUPLERS ARE TO DEVELOP <br />125 % OF THE REQUIRED <br />YIELD STRENGTH OF THE BAR AND ARE TO BE APPROVED BY THE ENGINEER OF <br />RECORD. <br />DESIGN COVER REQUIREMENTS <br />C-I-P CONCRETE FORMED AGAINST EARTH <br />„ <br />3 <br />C-I-P CONCRETE EXPOSED TO EXTERIOR <br />2" <br />C-I-P CONCRETE NOT EXPOSED <br />1' <br />GROUT FILLED MASONRY :�° <br />WELDED WIRE FABRIC (WWF): ASTM A-185 / A 185M-14 <br />DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 318-11 <br />(STRUCTURAL CONCRETE) <br />ACI 530-16 (MASONRY STRUCTURES) <br />5 DOWEL HORIZ. REBAR <br />EAM REINFORCING <br />z <br />111"T"/_WA,LL REINFOR�INGITH <br />N HIN'H <br />\`-#5 CORNER REBAR <br />GROUTED CELL <br />NOTE: ALL LAPS SHALL BE 25" MINIMUM <br />CORNER DETAIL — BOND BEAM <br />AND WALL REINFORCEMENT <br />B UTTER FI ELD INVESTMENTS I N C <br />5967 14TH STREET <br />ZEPHYRHILLS, FLORIDA <br />D.W. SMITH,M.S.,P.E. #53808 <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLASTON DRIVE-DADE CITY, FLORIDA 33525 <br />PHONE1813-469-2289 E-MAIL: dwsflpe@earthIInk:net <br />TERI BUTTERFIELD <br />CDC1332445 <br />RICK GOLLHARDT - DRAFTSMAN <br />813-781-3651 <br />rgollhardt@tampabay. rr. com <br />FOUNDATION PLAN <br />SCALE <br />DO NOT SCALE <br />DESIGNIDRAWN <br />R. GOLLHARDT <br />DATE <br />26 SEPT 2020 <br />CHECKED <br />D.W.S.,p.e. <br />SHEET OF <br />3 OF 10 <br />JOB NO. <br />2020-0831 <br />