2017 FBC RESIDENTIAL SECTION R703.4 FLASHING <br />APPROVED CORRISION RESISTANT FLASHING SHALL BE APPLIED SHINGLE FASHION IN A MANNER TO PREVENT ENTRY <br />OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURE FRAMING COMPONENTS. <br />SELF ADHERED MENBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. ALL EXTERIOR FENESTRATION <br />PRODUCTS SHALL BE SEALED AT THE JUNCTION WITH THE BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA <br />800 OR ASTM C920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION. ASTM <br />C 1281 AAMA 812 OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE TYPE OF SEALANT. FLUID APPLIED <br />MEMBRANES USED AS FLASHING IN EXTERIOR WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION RESISTANT FLASHINGS SHALL BE INSTALLED AT <br />THE FOLLOWING LOCATIONS. <br />1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER RESISTANT BARRIER COMPLYING WITH SECTION <br />703.2 FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS SHALL COMPLY WITH AAMA <br />712. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR <br />MORE OF THE FOLLOWING. <br />1.1 THE FENESTRATION MANUFACTURERS INSTALLATION AND FLASHING INSTRUCTIONS OR THE APPLICATIONS <br />NOT ADDRESSED IN THE FENESTRATION MANUFACTURERS INSTRUCTIONS IN ACCORDANCE WITH THE <br />FLASHING MANUFACTURERS INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT <br />PROVIDED PAN FLASHING SHALL BE INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS <br />PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE <br />OF THE EXTERIOR WALL FINISH OR TO THE WATER RESISTANT BARRIER FOR SUBSEQUENT DRAINAGE <br />OPENINGS USING PAN FLASHING SHALL BE INCORPORATE FLASHING OR PROTECTION AT THE HEAD AND SIDES <br />MORE OF THE FOLLOWING. <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN PROFESSIONAL <br />1.3 IN ACCORDANCE WITH OTHER APPROVED METHODS <br />1.4 IN ACCORDANCE WITH FMA/AMMA 100 FMA/AAMA 200 FMA/WDMA 250 FMA/AMMA/WDMA 300 <br />OR FMA AAMA/WDMA 400 <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS <br />3. UNDER AND AT THE ENDS OF MASONRY WOOD OR METAL COPINGS AND SILLS <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM <br />5. WHERE EXTERIOR PORCHES, DECKS AND STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD FRAME CONSTRUCTION <br />6. AT WALL AND ROOF INTERSECTIONS <br />7. AT BUILT-IN GUTTERS <br />ATTACH WINDOW & DOOR FRAMES TO BLOCK WALL <br />WITH TAPCON SCREWS SPACED AT WINDOW/DOOR <br />MANUFACTURER'S SPEC'S (TAPCONS MUST PENETRATE <br />THROUGH BUCKSTRIPS & INTO BLOCK 1 1/4' MINIMUM) <br />P.T. BUCKS <br />ACHED TO <br />-I 0.09r x 1 <br />ULS SPACE <br />).C. MAXIMI <br />;ONRY BLO, <br />NOTE: WINDOWS & DOORS MUST BE INSTALLED SUCH <br />THAT THE MAXIMUM GAP BETWEEN THE FRAME <br />AND BUCKSTRIP IS 1/4"; IF THICKER BUCKSTRIP <br />MATERIAL IS NEEDED RIP IT FROM 1 1/2" MATERIAL <br />S ATTACH TO BLOCK WITH 3/16' TAPCONS AT 8' O.C. <br />(TAPCON MUST PENETRATE BLOCK 1 1/4' MINIMUM) <br />WINDOW BUCKSTRIP DETAIL DOOR BUCKSTRIP DETAIL <br />NOT TO SCALE NOT TO SCALE <br />MASONRY INSTALLATION - WINDOWS <br />BUCKSTRIPS SHOULD BE PLACED AND SET IN A BEAD OF SEALANT. SEAL THE EXTERIOR JOINT BETWEEN THE MASONRY AND THE <br />BUCKSTRIP. ALL GAPS ARE TO BE SEALED. BUCKSTRIPS WILL RUN THE ENTIRE LENGTH OF THE WINDOW OPENING. IF THE SILL IS <br />PRE -CAST, A BUCKSTRIP IS NOT REQUIRED. BUCKSTRIPS ARE TO BE MADE OF PRESSURE TREATED SPRUCE, YELLOW PINE, OR <br />COMPARABLE LUMBER. UNDER FLORIDA BUILDING CODE, A BEVEL OR TAPER LOCATED ON THE BUCK IS PERMITTED IF THE WINDOW <br />FRAME IS COMPLETELY SUPPORTED AT BOTH THE INTERIOR AND EXTERIOR BY THE BUCKSTRIP. <br />3/4" THICK WOOD BUCKSTRIPS <br />FASTENERS FOR INSTALLATION WILL BE MASONRY SCREWS (MINIMUM 3/16" X 2 3/4"), INSTALLED THROUGH THE BUCKSTRIP AND <br />WINDOW INTO THE MASONRY. WINDOW MAY BE SHIMMED AS NECESSARY PROVIDED A SCREW EMBEDMENT (MINIMUM 1 1/4") IS <br />MAINTAINED IN THE MASONRY. FASTENERS WILL BE LOCATED A MAXIMUM OF 4" FROM EACH CORNER AND A MAXIMUM OF 18" O.C. <br />THEREAFTER IT IS RECOMMENDED NOT TO INSTALL FASTENERS THROUGH THE SILL OF THE WINDOW. BUCKSTRIPS SHOULD MEASURE <br />NO LESS THAN 3/4" X 2 1 /8". <br />1 1/2" THICK (OR GREATER) WOOD BUCKSTRIPS (NOT SHOWN) <br />WINDOW FASTENERS FOR INSTALLATION SHOULD BE A MINIMUM #10 X 1 1/2" WOOD SCREWS, INSTALLED INTO THE BUCKSTRIP <br />THROUGH THE WINDOW. WINDOW MAY BE SHIMMED AS NECESSARY PROVIDED A SCREW EMBEDMENT (OF MINIMUM 1 1/4") IS <br />MAINTAINED IN THE BUCKSTRIP. FASTENERS SHOULD BE LOCATED A MAXIMUM OF 4" FROM EACH CORNER AND A MAXIMUM OF 18" <br />O.C. IT IS RECOMMENDED NOT TO INSTALL FASTENERS THROUGH THE SILL OF THE WINDOW. BUCKSTRIPS SHOULD BE NO LESS THAN <br />1 1/2" X 2 1/8". TO MAINTAIN A 1 1/4" EMBEDMENT, BUCKSTRIPS SHOULD BE INSTALLED USING MINIMUM 3/16" X 2 3/4" <br />''..I MASONRY SCREWS AND BE 18" O.C. THEREAFTER. <br />FRAME INSTALLATION - WINDOWS <br />" INSTALLATION FASTENERS FOR WINDOWS ARE TO BE A 1 1/2" (MINIMUM), 4D NAILS OR #6 X 1 1/2" DRYWALL SCREW, WITH AN <br />EMBEDMENT OF 1 1/2" (MINIMUM). FASTENERS SHOULD BE LOCATED AT A MAXIMUM OF 4" FROM EACH CORNER AND 18" O.C. <br />THEREAFTER FOR SCREWS AND 9" O.C. FOR NAILS. IT IS RECOMMENDED FOR ALL SCREWS AND/OR NAILS TO BE SEALED, <br />PREVENTING INTRODUCTION OF WATER AND AIR. PRODUCT MAY BE SHIMMED AS NECESSARY. <br />" <br />#5 VERT. HALL REINF. 1/2" x b" "L" BOLT <br />FILL CELLS SOLID (3 PER SIDE) <br />P.T. DOOR STOP <br />2xb P.T. #2 5YP JAMB II <br />TRAGK/BRAGKET <br />FASTEN PER MANUF. 5PEG5. <br />GARAGE DOOR ATTACHMENT DETAIL <br />NOT TO SCALE <br />GARAGE DOOR JAMB <br />NOT TO SCALE <br />ASPHALT ROOF S1 <br />UNDERLAPM <br />VENT HOOD <br />FLA <br />R�L/I V LUI \ <br />ROOF VENTS <br />(OFF RIDGE) DETAIL <br />INSTALL SHINGLES OVER FLANGE <br />❑PTI❑NAL, AT HEAD <br />LEAD BOOT FLASHING W/ INTEGRAL SHINGLE RO❑FING OVER 15# FELT <br />FLANGE SET IN PLASTIC ROOF CEMENT OVER 7/16' OR 15/32' CDX <br />PLYWOOD <br />VENT SEE <br />SIZE ANDCL❑CATI❑NSMBING F❑R <br />FLEXIBLE BOOT FLASHING WITH <br />INTEGRAL FLANGE SET IN <br />PLASTIC ROOF CEMENT <br />INSTALL FLANGE OVER <br />SHINGLE AT BASF ---,.- <br />NOTES, <br />1, INSTALL IN STRICT ACCORDANCE WITH <br />MANUFACTURERS WRITTEN INSTRUCTI❑NS <br />2. APPLY R❑❑FING CEMENT OR <br />SELF -ADHERING FLASHING OVER FLANGE AT <br />HEAD ONLY <br />ROOF PENETRATION <br />FLASHING DETAIL <br />VALLEY 1 S <br />ROOF I <br />CUT TOP CORNER OF UNDERLAYMENT TO <br />INSURE PROPER DIVERSION OF WATER IN <br />THE METAL VALLEY <br />ROOF UNDERLAYME <br />VALLEY FLASHING (EXTEND ENTIF <br />WIDTH OF VALLEY METAL BEYONI <br />ROOF EDGE <br />STANDARD HIP & RIDGE CUT <br />FROM METRIC <br />THREE TAB SHINGLES <br />PREVAILING <br />5" <br />WIND DIRECTION <br />'--5 5/8" FAS1 <br />DISTANCE <br />STANDARD <br />MANSARD OR <br />NORMAL WIND AREAS HIGH WIND AREAS <br />o. <br />5" EXPOSURE <br />UNDERLAPMENT TO LAP OVER <br />VALLEY METAL A MINIMUM OF 2" <br />VALLEY UNDERLA YIVIENT do <br />FLASHING DETAIL <br />SHINGLE NAILING NOTES: <br />ALL NAILS MUST PENETRATE AT LEAST 3/4" INTO <br />THE WOOD ROOF DECK. <br />NAIL SHINGLES WITH 11 OR 12 GAUGE GALVANIZED NAILS <br />WITH 3/8" DIAMETER HEADS - 6 REQUIRED (AS SHOWN <br />IN "HIGH WIND AREAS") <br />ROOF -TO -WALL FLASHING NOTES: <br />4" X 5" ANGLE FLASHING - 26 GAUGE GALVANIZED METAL, <br />RUBBER VALLEY FLASHING OR 12" WIDE - 26 GAUGE <br />GALVANIZED METAL WITH SHINGLES OVER THE TOP. <br />MATERIAL SPECIFICATIONS: <br />UNDERLAYMENT SHALL CONFORM TO ASTM D226, TYPE I <br />OR ASTM 4869, TYPE I. <br />ENING FLASHING FOR ASPHALT SHINGLES SHALL COMPLY WITH <br />FBC R905.2.8 <br />ASPHALT SHINGLES SHALL COMPLY TO ASTM D225 OR <br />ASTM D3462. <br />VALLEY LINER <br />UNDERLAYMEN <br />2„ <br />-6" MIN. <br />-EXTRA -NAIL <br />ASPHALT PLASTIC <br />CEMENT <br />CLIP <br />CORNER <br />ROOF SHINGLE 8c FLASHING INSTALLATION SPEC'S <br />NOT TO SCALE <br />hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition <br />David W. Smith, P.E. #53608 <br />NAILING SGHEDULE <br />ALL NAILS ARE d GOMMON NUMBER AND 5PAGIN6 <br />LED6ER STRIP <br />16d <br />3 ® EA. J015T <br />50LE PL. TO J015T OR 5LK'6-FACE NAIL <br />16d <br />Ib' O.G. <br />TOP OR 50LE PL. TO 5TUD-END NAIL <br />Ibd <br />2 <br />STUD TO 50LE PL.-TOE NAIL <br />bd/Ibd <br />3/2 <br />DBL. 5TUD5-FACE NAIL <br />IOd <br />24" O.G. <br />DBL. TOP PLATE5-FACE NAIL <br />IOd <br />I6' O.G. <br />GONTINUOU5 HD'R THO PLAGE5 <br />Ibd <br />16' O.G. ALONG EA. EDGE <br />GONTINUOU5 HD'R TO STUD -TOE NAIL <br />bd <br />3 <br />IXb SHEATHING OR LE55 TO EA. BRN'6-FADE NAIL <br />bd <br />2 <br />OVER IXb 5HEATHIN6 TO EA. BRN'6-FACE NAIL <br />bd <br />2 <br />BUILT UP CORNER 5TU05 <br />IOd <br />24" O.G. <br />BUILT UP 61RDER5 AND BM'5 Ut' TO TRU55 MEMBERS <br />IOd <br />32" O.G. ® TOP AND BOTT. AND 5TA66ERED <br />2 END5 ® EA. 5PLIGE <br />1/2" 6YP5UM 5HEATHIN6 <br />II 6A. 1-112" 6ALV.1116" HEAD. <br />4" ON EDGE b" IN FIELD <br />5/b" 6YP5UM 5HEATHIN6 <br />II 6A. 1-3/4" 6ALV.1/I6" HEAD. <br />4" ON EDGE b" IN FIELD <br />112" 6YP5UM HALLBOARD <br />I-3/b" DRYWALL NAIL 1/I6" HEAD. <br />T ON GEILIN6 W ON KkL5 <br />5/b" 6YP5UM HALLBOARD <br />I-112" DRYWALL NAIL 1/I6' HEAD. <br />1" ON GEILIN6 WON WALL5 <br />HARD BD.. LAP 51DIN6-DIREGT TO 5TUD <br />bd GORRO51ON RE515TANT W/ MIN. <br />SHANK DIA. OF .099" AND A MIN. <br />HD. DIA. OF 24" <br />16' O.G. ® TOP AND BOTTOM EDGES <br />HARD BD.. LAP 51DIN6 OVER 5HEATHIN6 <br />IOd GORRO510N RE515TANT W/ MIN. <br />SHANK DIA. OF .099" AND A MIN. <br />HD. DIA. OF 24" <br />Ib' O.G. ® TOP AND BOTTOM ED6E5 <br />HARD BD.. PANEL 51DIN6 DIRECT TO 5TUD5 <br />bd CORRO51ON RE515TANT W/ MIN. <br />5HANK DIA. OF .042" AND A MIN. <br />HD. DIA. OF 225" <br />b" O.G. ® E06E5 AND 12" O.G. <br />INTERMEDIATE SUPPORT5 <br />HARD BD.. PANEL 510IN6 OVER 5HEATHIN6 <br />bd GORRO51ON RE515TANT H/ MIN. <br />5HANK DIA. OF .OG2" AND A MIN. <br />HD. DIA. OF 225" <br />b" O.G. ® E06E5 AND 12" O.G. <br />INTERMEDIATE 5UPPORT5 <br />NAILING SCHEDULE <br />REQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS <br />(RE: FBRC R308.4) <br />R308.3 HUMAN IMPACT LOADS. INDIVIDUAL GLAZED AREAS INCLUDING GLASS MIRRORS IN HAZARDOUS LOCATIONS SUCH AS THOSE <br />INDICATED AS DEFINED IN SECTION R308.4 SHALL PASS THE TEST REQUIREMENTS OF CPSC 18 CFR, PART 1201 CRITERIA FOR <br />CATEGORY I OR CATEGORY 11 AS INDICATED IN TABLE R306.3.1 <br />EXCEPTIONS: <br />1. POLISHED WIRED GLASS FOR USE IN FIRE DOORS AND OTHER FIRE RESISTANT LOCATIONS SHALL COMPANY WITH ANSI Z97.1-14 <br />2. LOUVERED WINDOWS AND JALOUSIES SHALL COMPANY WITH SECTION R306.2 <br />R308.4 HAZARDOUS LOCATIONS. <br />THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS LOCATIONS FOR THE PURPOSE OF GLAZING: <br />1. GLAZING IN SWINGING DOORS EXCEPT JALOUSIES. <br />2. GLAZING IN FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES AND PANELS IN SLIDING AND BIFOLD CLOSET DOOR <br />ASSEMBLIES. <br />3. GLAZING IN STORM DOORS. <br />4. GLAZING IN ALL UNFRAMED SWINGING DOORS. <br />5. GLAZJNG IN DOORS AND ENCLOSURES FOR HOT TUBS WHIRLPOOLS SAUNAS, STEAM ROOMS BATHTUBS, AND SHOWERS. <br />GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMOARTMENTS WHERE THE 6OTTOM EXPOSED EDGE OF THE <br />GLAZING IS LESS THAN 60 INCHES(1524MM) MEASURED VERTICALLY ABOVE ANY STANDING OR WAL.IONG SURFACE. <br />6. GLAZING, IN AN INDMDUAL FIXED OPERABLE PANEL ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL EDGE IS <br />WITHIN A 244NCHS810MMIARC OF THE DOOR IN A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES <br />(1524MM) ABOVE THE FLOOR OR WALKING SURFACE. <br />7. GLAZING IN AN INDMDUAL FIXED OR OPERABLE PANEL OTHER THAN THOSE LOCATIONS DESCRIBED IN ITEMS 5 AND 6 <br />ABOVE THAT MEETS ALL OF THE FOLLOWING CONDMRi: <br />T.1 DOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET (0.838 M2)_ <br />7.2 BOTTOM EDGE LESS THAN 18 INCHES C91' <br />MM ABOVE THE FLOOR. <br />7.3 TOP EDGE GREATER THAN 38 INCHE84 MM3 ABOVE THE FLOOR.7A ONE OR MORE WALING SURFACESIN 36 INCHES (914 MM) HORIZONTALLY OF THE GLAZING. <br />8. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE WALKING SURFACE INCLUDED ARE STRUCTURAL <br />BALUSTER PANELS AND NONSTR�ORSAL IN FILL -PANELS. <br />9. GLAZING IN WALLS AND FENCES EEroci--0 NG INDOOR AND OUTDOOR SWIMMING POOLS, HOT TUBS AND SPAS WHERE THE <br />BOTTOM EDGE OF THE GLAZING IS LESS THAN 80 INCHES (1524 MM) ABOVE A WALKING SURFACE AND WITHIN 80 INCHES (1524 <br />MM LHOR17 NTALI.Y OF THE WATER'S EDGE. THIS SHALL APPLY TO SINGLE GLA23NG AND ALL PANES IN MULTIPLE GLAZING. <br />10. NG ADJACENT TO STAIRWAYS, LANDINGS, AND RAMPS WITHIN 36 INCHES 914 MM) HORIZONTALLY OF A WALING <br />SURFACE WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS THAN 80 INCH �S (1524 MM) ABOVE THE PLANE OF THE <br />ADJACENT WALKING SURFACE. <br />I I. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES 1524 MM) HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN <br />TREAD. <br />WHEN THE EXPOSED SURFACE OF THIS GLASS IS LESS THAN 80 INCHES (1524 MM) ABOVE THE NOSE OF THE <br />EXCEPTION: THE FOLLOWING PRODUCTS, MATERIALS AND USES ARE EXEMPT FROM THE ABOVE HAZARDOUS LOCATIONS: <br />1. OPENINGS IN DOORS THROUGH WHICH A 3-INCH(76 MM) SPHERE IS UNABLE TO PASS. <br />2. DECORATIVE GLASS IN ITEMS 1 OR 7. <br />3. GLAZING IN SECTION R306A, ft-m 8, WHEN THERE IS AN INTERVENING WALL OR OTHER PERMANENT BARRIER BETWEEN THE <br />DOOR AND THE GLAZING. <br />4. GLAZINO IN SECTION R 308r4.2, ITEM 3, IN WALLS PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION OR <br />WHERE ACCESS THROUGH THE DOOR IS TO A CLOSET OR STORAGE AREA 3 FEET (914 MM) OR LESS IN DEPTH. GLAZING IN <br />THESE APPLICATIONS SHALL COMPANY WITH SECTION ii306A, REM 2. <br />5. GLAZING INCHES IN SEC71ON 2 INCHES (911R308.4.3, <br />* MM , WHEN 51 MM) AABOVEE THE FLOOR. VE BAR I HE BAR SHILL BE CINSTALLED ON APABLE OF�WITHSTANDING A HORIZONTAL. BLE SIDE(S) OF THE GLAZING LOAD <br />OF 50 POUNDS PER LINEAR FOOT KGIM) WITHOUT CONTACTING THE GLASS AND BE A MINIMUM OF 1 %*WM8(wWA)N <br />HEIGHT. <br />8. OUTBOARD PANES IN INSULATING G(�LASSS UNITS (/FgAND OT)bHER MULTIPLE GLAZED PANELS IN SECTION R308.4 n EM 7 WHEN <br />7. L HE BOTTOM EDGE OF THE GLASS IS 25 FEET OUVERED�WMDOVI 3 AN45 D JALOl S1E3 COMPLYING WITH THE REQU lug EI�AENT ADJACENTSECTION TO OR MORE ABOVE GRADE, A ROOF WR908.20 EXTERIORiik GLASS ' c3R OTHER <br />8. MIRRORS AND OTHER GLASS PANELS MOUNTED OR HUNG ON A SURFACE THAT PROVIDES A CONTINUOUS BACKING <br />SUPPORT. <br />9. SAFETY GLAZING IN SECTION R308A, IS NOT REQUIRED WHERE: <br />9.1 THE SIDE OF STAIRWAY, LANDING OR RAMP HAS A GUARDRAIL OR HANDRAIL, INCLUDING BALUSTERS OR <br />IN -FILL PANELS COMPLYING WITH THE PREVISIONS OF SECTION 1014 OF THE FLORIDA BUILDING CODE, BUILDING; AND <br />92 THE PLANE OF !RE GLASS IS GREATER THEN 18 INCHES (457 MM) FROM THE RAILING. <br />TABLE R302.6 DWELLING -GARAGE SEPARATION <br />SEPARATION <br />MATERIAL <br />FROM THE RESIDENCE AND ATTICS <br />EQUIVALl THAAP1/2 TO TH UGARAGE SIDE <br />FROM HABITABLE ROOMS ABOVE THE GARAGE <br />N8TRI,ESOSR TMXPN- VCH TYPE X GYPSUM <br />USEDCFORESSEPERATIONTREQUIREDRBYETHS SECTION LIES <br />NOT <br />TEQUIVALENN 1/2-INCH GYPSUM BOARD <br />GARAGES LOCATED LESS THAN 3 FEET FROM A DWELLING <br />UNIT ON SAME LOT <br />NOT LESS THAN 1 2-INCH GYPSUM BOARD OR <br />EQUIVALENT APP IED TO THE INTERIOR SIDE <br />OF EXTERIOR WALLS THAT ARE WITHIN THIS AREA <br />ENGINEER LICENCE #53608 <br />BUTTERFIELD INVESTMENTS INC RICK GOLLHARDT - DRAFTSMAN <br />5985 14TH STREET 813-781-3651 <br />ZEPHYRHILLS, FLORIDA rgollhardt@tampabay.rr.com <br />D.W. SMITH ,M.S.9P.E.#53608 DETAILS <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLASTON DRIVE-DADE CITY, FLORIDA 33525 SCALE DATE <br />PHONE: 813-469-2289 E-MAIL: dwsflpe@earthhnk. net DO NOT SCALE 30 AUG 2020 <br />DESIGN/DRAWN CHECKED <br />R. GOLLHARDT D.W.S.,p.e. <br />SHEET OF <br />7 OF 9 <br />JOB NO, <br />2020-0818 <br />