Laserfiche WebLink
ELECTRICAL, PLUMBING & MECHANICAL: <br />IN ACCORDANCE WITH CHAPTER 471.003 (2 (1) OF THE FLORIDA ADMINISTRATIVE CODE, ELECTRICAL <br />PLUMBING AND MECHANICAL SYSTEMS SH LL BE DESIGNED BY THE RESPECTIVE CONTRACTOR TO <br />MEET ALL APPLICABLE CODES. THE ELECTRICAL, PLUMBING AND MECHANICAL SYSTEMS DRAWN HEREON <br />ARE BASED UPON A DESIGN PROVIDED BY THE OWNER TO ADDRESS HIS/HER REQUIREMENTS. <br />ALL ELECTRICAL OUTLETS IN BATHROOMS, KITCHEN, (WITHIN 6' FEET OR SINKS), GARAGE AND AT <br />EXTERIOR LOCATIONS SHALL BE WIRED INTO A GROUND FAULT INTERRUPTER "GFI" CIRCUIT. "AFI" CIRCUIT. <br />ALL ELECTRICAL OUTLETS IN BEDROOMS & FIXTURES SHALL BE WIRED INTO AN ARC —FAULT INTERRUPTER. <br />SMOKE DETECTORS SHALL BE PLACE IN EACH BEDROOM AND IN HALL WAY AREAS ADJACENT <br />TO BEDROOM AND OTHER LIVING AREAS. <br />GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C. <br />DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR CEILING SEPARING THE DWELLING FROM THE <br />GARAGE SHELL BE CONSTRUCTED OF MINIMUM NO.26 GAUGE SHEET OR OTHER APPROVED MATERIALS <br />AND SHALL HAVE NO OPENINGS INTO THE GARAGE (FBC 6TH EDITION 2017 R309) <br />FLORIDA STATUTE 471 <br />ONLY REQUIRES ENGINEERING ON RESIDENTIAL IF THE COST OF THE INDIVIDUAL PLUMBING, ELECTRICAL, <br />OR MECHANICAL IS OVER $125,000 OR IS OVER 250 FIXTURE UNITS PLUMBING, OVER 600 AMPS <br />ELECTRICAL AND 15 TONS OR OVER MECHANICAL. <br />FBC BUILDING CHAPTER 1 (105.3.1.2) <br />2' VTR <br />PLUMBING NOTES: <br />BATHROOM PLUMBING <br />SHOWER HEAD <br />SHOWER VALVE <br />TUB/SHOWER HEAD <br />TUB/SHOWER VALVE <br />TUB/SHOWER SPOUT <br />FIXTURE HEIGHTS: <br />77" <br />ABV. SHOWER F.F. <br />46" <br />ABV. SHOWER F.F <br />80" <br />A.F.F. <br />3 0 " <br />A. F [�_. <br />22" <br />A.F.F. <br />TAP <br />OUTSIDE WATER TAP <br />WASHER <br />2' VTR I ' <br />I <br />I 2' <br />` \ I 2' VTR <br />SINK <br />2 SINK SINK WC �'\ <br />v/ SHOWER i <br />\ z <br />`\ TUB <br />SINK <br />/' 3' WC <br />\ 3' <br />4' C. ❑, <br />PLUMBINGISOMETRIC � LOCATE AND CONNECT <br />TO SEWER <br />PLUMBING: <br />ALL PLUMBING FIXTURE LOCATIONS ARE TO BE DETERMINED BY THE PLUMBING CONTRACTOR. <br />IN ACCORDANCE WITH CHAPTER 471.003 (2) OF THE FLORIDA ADMINSTRATION CODE, <br />PLUMBING SYSTEMS SHALL BE DESIGNED BY THE <br />RESPECTIVE CONTRACTORS TO MEET ALL APPLICABLE CODES. THE SYSTEMS DRAWN <br />HEREON ARE BASED UPON THE HOMEOWNERS/CONTRACTORS REQUIREMENTS. <br />ALL FIXTURE LOCATIONS MUST BE VERIFIED FROM FLOOR PLAN AND IS THE RESPONSIBILITY OF <br />PLUMBING CONTRACTOR TO PLACE FIXTURES IN CORRECT LOCATION. PLUMBING DRAIN LAYOUT <br />WILL BE DETERMINED IN FIELD BY CONTRACTOR. <br />PLUMBING LA YO UT <br />- 2" <br />4' C. ❑, <br />' LOCATE AND CONNECT <br />TO SEWER <br />BUTTERFIELD INVESTMENTS INC <br />5985 14TH STREET <br />ZEPHYRHILLS, FLORIDA <br />D.W.SMITH,M.S.,P.E.#53608 <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLASTON DRIVE—DADE CITY,FLORIDA 33525 <br />PHONE1813-469-2289 E-MAIL: dwsflpe@earthlink.net <br />RICK GOLLHARDT - DRAFTSMAN <br />813- 781- 3651 <br />rgollhardt@tampabay. rr. coati <br />ELECTRICAL SHEET OF <br />8 OF 9 <br />SCALE DATE JOB NO, <br />DO NOT SCALE 30 AUG 2020 <br />DESIGN/DRAWN CHECKED 2020-0818 <br />R. GOLLHARDT D.W.S.,p.e. <br />