u <br />MECHANICAL: <br />CONDENSATE LINES SHALL DISCHARGE AT LEAST 12" AWAY FROM THE STRUCTURE SIDEWALL, WHETHER BY UNDERGROUND <br />PIPING, TAIL EXTENSIONS, OR SPLASH BLOCKS. <br />2017 FMC, 6TH EDITION — EQUIPMENT DISCONNECT MUST BE WITHIN SIGHT OF THE EQUIPMENT. <br />BATHROOMS MUST BE VENTILATED MECHANICALLY AND EXHAUSTED TO BUILDING EXTERIOR. <br />AIR HANDLER FLOAT SWITCHES ARE REQUIRED TO SHUT DOWN THE UNIT OR OTHER APPROVED DEVICE TO ALERT THE HOME <br />OWNER THAT THE CONDENSATE DRAIN LINE IS NOT WORKING PROPERLY. <br />THERE MUST BE A NOTICE POSTED ON THE ELECTRICAL PANEL ALERTING THE HOME OWNER THAT THE AIR HANDLER IS <br />LOCATED IN THE ATTIC (WHEN APPLICABLE). <br />NOTE: <br />MECHANICAL CONTRACTOR TO DETERMINE UNIT SIZE PER ENERGY CALCULATIONS <br />IN ACCORDANCE WITH CHAPTER 471.003 (2) OF THE FLORIDA ADMINSTRATION CODE, <br />MECHANICAL SYSTEMS SHALL BE DESIGNED BY THE <br />RESPECTIVE CONTRACTORS TO MEET ALL APPLICABLE CODES. THE SYSTEMS DRAWN <br />HEREON ARE BASED UPON THE HOMEOWNERS/CONTRACTORS REQUIREMENTS. <br />HVAC <br />SMOKE DETECTORS: <br />SMOKE DETECTOR PLACEMENT AND LOCATION SHALL BE CHECKED AT FRAMING. THE PROPER PLACEMENT OF UNITS SHALL BE <br />IN ACCORDANCE WITH THE NATIONAL FIRE PREVENTION CODE SAFETY ACT. MINIMUM REQUIREMENT SHALL BE AS SET FORTH IN <br />6TH EDITION, 2017 FLORIDA BUILDING CODE AND NFPA-70/NATIONAL ELECTRIC CODE 2017 (NEC2017). <br />CARBON MONOXIDE DETECTORS: <br />EVERY BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS ISSUED ON OR AFTER 07/01/08 AND HAVING A <br />FOSSIL—FUEL—BURINING HEATER OR APPLIANCE, A FIREPLACE, OR AN ATTACHED GARAGE SHALL HAVE AN OPERATIONAL <br />CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH ROOM USED FOR SLEEPING PURPOSED. IN NEW CONSTRUCTION, <br />ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHEN SUCH WIRING IS SERVED FROM THE LOCAL <br />POWER UTILITY. SUCH ALARMS SHALL HAVE BATTERY BACK UP. <br />ELECTRICAL: <br />ALL OUTLETS SHALL BE ON AN AFCI (ARC FAULT CIRCUIT INTERRUPTER) PROTECTED CIRCUIT & TAMPER PROOF, PER <br />2017 6TH EDITION FLORIDA BUILDING CODE, RESIDENTIAL (PART VIII — ELECTRICAL) <br />NEC 2017: 210.12 — ARC FAULT PROTECTION IS NO LONGER LIMITED TO SLEEPING AREAS AND NOW INCLUDE KITCHENS. <br />NEC 2017: 210.8 — INCLUDE GFCI PROTECTION ON CIRCUITS INCLUDING BUT NOT LIMITED TO OUTDOORS, DISHWASHERS, <br />PORCH AND LANAI. <br />ALL OUTSIDE MECHANICAL EQUIPMENT TO HAVE (1) 110 VOLT GFI WP OUTLET WITHIN 25' OF EQUIPMENT IN SITE PLAN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLETS HEIGHTS AS MEASURED FROM FINISHED FLOOR <br />CENTERED LINE OF THE BOX TO BE: 12" AFF (GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE POSSIBLE <br />3. ELECTRICAL SWITCHES TO BE 42" CENTERLINE AFF. <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. ALL WORK SHALL <br />BE DONE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, LATEST <br />EDITION, BY LICENSED ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE <br />FOR THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & ACCESSORIES. <br />5, GROUND WIRE FORM REBAR TO ELECTRICAL PANEL PER N.E.C. 2017 <br />$ <br />SWITCH <br />$3 <br />3 WAY SWITCH <br />$4 <br />4 WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />8 <br />110 V RECEPTICLE(1/2 SWITCHED) <br />6u <br />110 V RECEPTICLE <br />t,7�1 <br />110 V RECEPTICLE - GROUND FAULT <br />t}�FI <br />110 V RECEPTICLE - ARC FAULT <br />8w <br />110 V RECEPTICLE - WATERPROOF OUTLET <br />6 <br />220 V RECEPTICLE <br />IN <br />DUPLEX OUTLET IN FLOOR <br />16 <br />110 V QUAD <br />8. <br />110 V QUAD WATERPROOF OUTLET <br />® <br />RECESSED INCANDESCENT <br />LIGHT FIXTURE - WALL OR CEILING (TYP) <br />EXHAUST BATH FAN 110 V 50 CFM'S <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />FLOURESCENT FIXTURE <br />FLOOD LAMPS <br />Qp <br />�g <br />VANTITY LIGHT <br />c0 <br />PUSH BUTTON FOR GARAGE OPENER <br />S&D <br />SMOKE /FIRE DETECTOR/ALARM <br />CAM <br />SMOKE/CARBON MONOXIDE DETECTOR - COMBO <br />© <br />CARBON MONOXIDE DETECTOR <br />CEILING FAN ONLY <br />FAH W/L <br />CEILING FAN /LIGHT <br />a <br />DISCONNECT <br />ELECTRICAL METER <br />ELECTRICAL PANEL <br />3- 2/0 THNN CU FEEDERS <br />2" GALV RISER <br />"0/"JA210 <br />TMWC�200 AMP MAIN BREAKER <br />200 AMPPPANELL ONTINSIDEAGARAGE WALL <br />METER SOCKET <br />2" GALV NIPPLE <br />YIF AVAILABLE) SERVICE RODSCU 2 EACHIV8'-0" APART MIN. <br />DREN GROUND <br />�3/8" X 8' GROUND ROD <br />CONCRETE ENCASED "LIFER" ELECTTODE REQUIRED PER ART 250-50 <br />N.E.C. MUST BE INSPECTED PRIOR TO CONCRETE PLACEMENT. <br />ELECTRICAL <br />BUTTERFIELD INVESTMENTS INC RICK GOLLHARDT - DRAFTSMAN <br />5985 14TH STREET 813-781-3651 <br />ZEPHYRHILLS, FLORIDA rgollhardt@tampabay.rr.com <br />D.W. SMITH,M. S.,P.E. #53608 <br />FLORIDA PROFESSIONAL ENGINEER LICENSE NUMBER 53608 <br />PROJECTS ENGINEERING CONSULTANT <br />9909 WALLAST❑N DRIVE—DADE CITY, FLORIDA 33525 <br />PHONE:813-469-2289 E-MAIL: dwsflpe@earthlink, net <br />ELECTRICAL <br />HVAC <br />SCALE <br />DO NOT SCALE <br />SHEET ❑F- <br />9 OF 9 <br />L^I` JOB NO. <br />0 AUG 2020 <br />CHECKED 2020-0818 <br />0 <br />D.W.S.,p.e. <br />DESIGN/DRAWN <br />R. GOLLHARDT <br />