My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6373 Ten Acre Ct
Zephyrhills
>
Building Department
>
Building Plans
>
6373 Ten Acre Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 7:50:00 AM
Creation date
2/19/2025 8:53:05 AM
Metadata
Fields
Template:
Building Plans
Street #
6373
Location
Ten Acre Ct
Contractor
Lennar Homes LLC
Building Plans - Permit #
5286
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELEC <br />METER <br />L — — — — J <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION A <br />1 /4" = 1 '-0" <br />1I <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />O <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bars Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />0 C T 18 2922 <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH- <br />4 1/2" <br />DOORJAMB DUPLEX 19 <br />OUTLET c0 <br />TRIM--- <br />BASE--- <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />kTC <br />SMOKE DETECTOR <br />1'-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />®= 110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-© PUSH BUTTON FOR GARAGE DOOR OPENER <br />-fl DIMMER SWITCH AT 36" <br />-� PUSH-BUTTON DOORBELL <br />{- CLG MNT LT FIXTURE <br />-}- CLG MNT PREWIRE - FIXTURE BY OWNER <br />-} SURFACE MNT FIXTURE <br />} WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />50W PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />50W MR16 4" LOW VOLTAGE OWNER <br />Q 50W PAR20 NFL 4" MINI ROUND RECESS <br />�0 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />cs <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />0 SMOKE DETECTOR <br />cU-18= UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />9;:24:F1 24" VANITY LIGHTING <br />F,;-,36:;;� 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />Q EXHAUST FAN <br />p DOUBLE FLOOD LIGHT W/ COVERS AND <br />C3 15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />O CEILING MNT SPEAKER <br />IM CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />-N&D ELEC PANEL <br />® VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />A/C REGISTER <br />0 THERMOSTAT <br />M SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />to <br />D ^ o <br />W L i 0 r? U <br />M C14 v <br />�I~' C)V co <br />-0,co <br />Av� <br />W L O <br />2 <br />0 <br />VJ O 9 Q <br />S <br />.N <br />w O'er N � <br />V �� C <br />i o EM 9 <br />70 <br />0 �1� <br />r L— a _0 <br />W <br />�LLI llj wOH- <br />�Q T _j W~zW z <br />O OLL O <br />a0 <br />I— <br />ZLZ2Ha_JOQLl <br />OW0-WOZOWOOmO�U�ZQ <br />J <br />Q <br />OZ <br />p <br />O_'~W <br />WQ�Q <br />�pQ <br />LL <br />Uj <br />00W o oQz<Q <br />LL Q 0 F- Q LL <br />O <br />Z N <br />OW <br />0E-cMO <br />Q w CM � <br />(1) <br />— <br />z <br />< W <br />00 <br />zv� <br />W <br />W <br />JC:) <br />O <br />d' <br />co <br />O <br />o <br />0 <br />0 <br />0 <br />0 <br />Nti <br />N <br />N <br />O <br />C)Co <br />N <br />O <br />C0 <br />C)c- <br />O <br />� <br />O <br />N <br />O <br />i <br />1 <br />z <br />O <br />(V <br />ILA <br />W <br />o <br />0 <br />0 <br />0 <br />0Lao <br />l <br />I <br />i <br />> <br />N <br />(`M <br />4 <br />L6 <br />' <br />Cr <br />w <br />Z <br />Z <br />W <br />Z <br />w <br />C)Q <br />�--+ <br />Wcy) <br />Z Co <br />O <br />O <br />v <br />W O <br />�Z> <br />O <br />Oro <br />Q <br />z <br />CL�a <br />LUWQ <br />m L- w <br />(V <br />Zoo <br />W <br />Q�Z) <br />0 <br />N <br />0 <br />2;�g <br />zoo <br />Z <br />U <br />azLL <br />LL <br />�z <br />0U <br />0 <br />m <br />Z <br />z <br />z <br />W <br />W <br />C) <br />0 <br />0 <br />LAST PLOT DATE <br />O <br />April 29, 2022 <br />Z <br />_ <br />0 <br />J <br />1ST FLOOR <br />ELECTRICAL PLAN A <br />
The URL can be used to link to this page
Your browser does not support the video tag.