VENTILIATION SCHEDULE <br />ROOM NAME <br />OCCUPANCY <br />FLOOR <br />NUMBER OF <br />PEOPLE OA RATE <br />AREA OA RATE TOTAL OA <br />TOTAL EA <br />SUPPLY <br />OA CFM <br />RETURN <br />EXHAUST SUPPLY FAN EXHAUST <br />CLASSIFICATION <br />AREA FT2 <br />OCCUPANTS <br />(CFM/PERSON) <br />(CFM/SF) CFM <br />CFM_ <br />CFM <br />CFM <br />CFM FAN <br />PSC WORKROOM <br />OFFICE <br />50 <br />2 <br />5.0 <br />0.06 13 <br />0 <br />354 <br />15 <br />339 <br />0 HP-2 - <br />PSC TOILET <br />RESTROOM <br />53 <br />0 <br />0.0 <br />0.00 <br />0 <br />75 <br />0 <br />0 <br />0 <br />75 <br />- <br />EF-1 <br />PSC SERVICE AREA <br />OFFICE <br />254 <br />2 <br />5.0 <br />0.06 <br />25 <br />0 <br />251 <br />25 <br />226 <br />0 <br />HP-1 <br />- <br />- <br />- <br />- <br />38 <br />40 <br />595 <br />75 <br />- <br />TOTAL <br />357 <br />4 <br />75 <br />605 <br />- <br />4- <br />C <br />a) <br />E <br />a <br />0 <br />aD <br />a� <br />r. <br />c <br />Lo <br />0 0 <br />Lo <br />v � <br />cca o <br />c: 00 m <br />c 0 J <br />i ?E <br />CL <br />>T=- <br />L' a) <br />vJ O 0 <br />EXHAUST FAN SCHEDULE <br />r <br />TAG LOCATION SERVICE CFM ESP IN MOTOR DATA WEIGHT (LB) MANUFACTURER AND MODEL <br />RPM DRIVE HP BHP VOLT PH HZ a <br />EF 1 TOILET ROOM TOILET 75 .100 1050 DIRECT 1/200 .01 120 1 60 15 GREENHECK G-060-E El <br />8 ill <br />REMARKS: rn a <br />1. PROVIDE FAN WITH MOTOR STATER, DISCONNECT SWITCH, BACKDRAFT DAMPER, AND BIRDSCREEN. -� <br />2. EXHAUST FAN TO BE CONTROLLED BY SWITCH OUTSIDE OF TOILET ROOM. (D m R <br />3. PROVIDE WITH PRICE-80 EGG CRATE GRILLE MOUNTED IN NEW TOILET CEILING DIRECTLY BELOW EF-1. CIDcn <br />s <br />c� <br />OUTDOOR CONDENSING UNIT SCHEDULE <br />COOLING HEATING <br />TAG MAKENODEL COOLING <br />R) HEATING <br />R) REFRIG. MCA MOCP ELECTRICAL SEER WEIGHT REMARKS <br />CU 1 YORK / DHM24CMB215 26000 29000 R410A 20 30 20811/60 16 146 ALL <br />REMARKS: <br />1. UNITS TO HAVE 114" REFRIGERANT AND 3/8" SUCTION LINES AND TO BE CONNECTED PER MANUFACTERER'S STANDARDS. <br />2. INSTALL LABEL ON CONDENSING UNIT. <br />INDOOR HEAT PUMP SCHEDULE <br />COOLING CAP HEATING CAP <br />TAG MAKEIMODEL CFM BTU BTU VIPH/HZ MCA MOCP WEIGHT REMARKS <br />HP 1 YORK / DHMW18NKB21S 353 15359 17065 208/1/60 1 15 51 ALL <br />HP 2 YORK / DHMW18NKB21S 353 15359 17065 208/1/60 1 15 51 ALL <br />REMARKS: <br />1. UNITS TO HAVE WIRED ZONE CONTROLLER MODEL DWCMW THERMOSTAT WITH SET POINT DISPLAY AND LOCAL OCCUPANT CONTROLS FROM 68F TO 76F. <br />2. UNITS ARE TO HAVE REFIGERANT R410-A OR OTHER NON-HCFC REFRIGERANT TO BE USED. <br />3. UNITS TO HAVE OVERFLOW SWITCH AND CONDENSATE PUMP. <br />NRTN, <br />?. <br />1. <br />' El <br />d <br />Q NO. kbiE <br />e As°- <br />N' ; ``,,�` <br />0 <br />O O <br />� M <br />� V <br />L) "t N <br />O O C C co <br />0 M O <br />_(n <br />LL Q <br />.0 c0 O N X <br />N(nHLL <br />L <br />� <br />CM <br />cM <br />(V <br />N <br />o <br />O <br />S <br />CD <br />Lo <br />Q <br />¢ c <br />N <br />9 <br />ll� <br />N <br />U w <br />O <br />� <br />�z0 <br />E <br />co N <br />C6 <br />C7 <br />N <br />U Q?�o <br />oU) <br />o <br />J — U) f+7 <br />c -p <br />L <br />_I Uj <br />.V .0 <br />U) <br />w <br />J <br />w <br />2 <br />(n <br />J <br />Q <br />U_ <br />Z <br />Q <br />2 <br />U <br />w <br />2 <br />0 <br />co <br />w <br />O <br />H <br />Z <br />_0 <br />a <br />0 <br />w <br />0 U) <br />Z <br />O <br />w <br />w <br />} <br />m <br />w <br />0 <br />I <br />N <br />Ln <br />M <br />M <br />ij) LL <br />Z ?, <br />W v <br />W <br />J <br />Qo <br />M <br />ti <br />O <br />CO <br />N <br />a <br />o <br />rn <br />O M <br />} <br />0� <br />J cn <br />m <br />Z <br />0 <br />W <br />N <br />L <br />L <br />W <br />~ <br />W <br />N <br />Q <br />0 <br />W <br />Ui <br />Q¢' <br />cv <br />M-61 0 <br />