Laserfiche WebLink
_ . I — i -_ __ _- _ . _— - _ I .. I � _ LL - 7 I I i _ 1 i I , I. I _ L.. __ -1 _ I _- <br />B <br />LP-6:10 <br />` LP-6:8 <br />LP-6:7 <br />EWH 01 <br /><zg02 <br />2s 10 02> -- - <br /><26 10 15>_ <br />- <br />LP-6:13----- <br />- - <br /><26 10 03>'LP-6' <br />i> GFI <br /><26 10 14> <br /><I26 10 1 <br />LP-6:9 <br /><261011>—HP <br />LP-6:12I <br />2 <br />'<26 10 07> <br />- J GFI <br />LP-6:9 <br /><26 10 06> <br />LP-6:16,18 <br />LP-6:11 <br />26 10 18> <br />0 08> <br />: <26 101I 10> <br />k<26 <br />i <br /><26 <br />10 01> <br />LP-6:6 LP-6:6 <br />- ---- <26 10 01> <br /><26 10 17> CU <br />LP-6:14 1 <br />- <br />LP-6:15,17 LP-6:6 <br />J <br />LP-6:5 <br /><26 10 16> <26 10 01 <br /><26 10 01> <br />F. <br />111f1)__- <br />rwmwmmmq <br />HP LP-6:16,18 <br />1\,_1fj <br /><26 10 18> <br />LP-6:5 <br />'6 10 01> <br />}-------- <br /><26 10 01>6 <br />LP-6:6 <br />LP-6:6 G <br /><26 10 01> <br /><26 10 08> <br />LP-6:5 <br />{�#J <26 10 02> <br />GLP-6:4 <br />-- <br />GFI <261012> <br />GFI 1-P-6 0 .14> `;26 10 08> <br /><26 10 09> <br />LP-6:19 <br />��..EF <br />,1 <br />NEW ELECTRICAL FLOOR PLAN <br />1 /4" = T-0" <br />_LP-6:3 <br /><4 � 0 04> <br />I LP-6:2 <br /><26 10 05> <br />LP-6:1 <br />PSC WORK __ .. ROOM <br />ULEM <br /><26 50 01 > <br />S -26 50 02> <br />LP-6:1 LP-6:1 I <br />UL UL <br />PSC SERVICE <br />AREA <br />I' <br />LP-6:1 10 LP-6:1 <br />i <br />I <br />I <br />UL UL <br />LP-6:1 LP-6:1 <br /><26 50 02,- <br /><26 50 03-, <br />UL ULEM LP-6:1 0 <br /><26 50 01 > E <br /><26 02> <br />LP-6:1 <br />ULEM <br /><26 50 01 > <br />mg lwamcel:iIII l►Lei ivupgogviIej:Imig[eT»:n <br />POWER KEY NOTES <br />Key Value Keynote Text <br />261001 ONE (1) 20A.120V,1 PH CIRCUIT FOR 20OW GENERAL PURPOSE DUPLEX <br />RECEPTACLE, MOUNTED AT V-6" A.F.F., UNLESS NOTED OTHERWISE. <br />261002 ONE (1) 20A, 120V,1PH CIRCUIT FOR GFCI DUPLEX RECEPTACLE MOUNTED AT V-6" <br />A.F.F. REFER TO ARCHITECTURAL INTERIOR ELEVATION DRAWING FOR ADDITIONAL <br />INFORMATION. <br />261003 ONE (1) 20A, 120V,1PH CIRCUIT FOR GFCI DUPLEX RECEPTACLE MOUNTED AT V-6" <br />A.F.F. FOR REFRIGERATORIFREEZER. <br />261004 ONE (1) 20A,120V,1PH CIRCUIT FOR (3) CHECK -IN KIOSK(S) MOUNTED AT V-6" A.F.F. <br />261005 ONE (1) 20A, 120V,1 PH CIRCUIT FOR DUPLEX RECEPTACLE MOUNTED AT 6-71/2" <br />A.F.F. FOR LCD MONITOR. <br />261006 ONE (1) 20A,120V,1 PH CIRCUIT FOR DUPLEX RECEPTACLE MOUNTED AT V-6" A.F.F. <br />FOR BIO DISPENSER BELOW COUNTER. <br />261007 ONE (1) 20A,120V,1 PH CIRCUIT FOR UNDER CABINET LIGHT FIXTURE. GFCI DUPLEX <br />RECEPTACLE MOUNTED AT 60"A.F.F.(ON CENTER, HORIZONTAL). <br />261008 PROVIDE NEW FIRE ALARM DEVICE AS NECESSARY. VERIFY EXISTING CONDITIONS <br />OF FIRE ALARM SYSTEM. MAINTAIN EXISTING CONNECTION TO FIRE ALARM SYSTEM <br />AS NECESSARY. <br />261009 COLD WATER SOLENOID VALVE. VERIFY EXACT LOCATION OF SWITCH PRIOR TO <br />INSTALLATION. SEE P-111 FOR MORE INFORMATION. <br />261010 PANIC BUTTON FOR LSP SPACE PROVIDED AND INSTALLED BY WALGREENS. VERIFY <br />EXACT SPECIFICATIONS, REQUIREMENTS, AND LOCATION WITH OWNER PRIOR TO <br />ROUGH -IN. <br />261011 ONE (1) 20A, 120V,1 PH CIRCUIT FOR FUTURE TECH CABINET QUAD OUTLET. FINAL <br />LOCATIONS TO BE VERIFIED WITH WALGREENS PROJECT MANAGER FOR FUTURE <br />TECH CABINET INSTALLATION. <br />261012 SWITCH FOR EXHAUST FAN LOCATED OUTSIDE RESTROOM. SWITCH DIRECTION "UP" <br />SHALL SHUT OFF FAN AND SWITCH DIRECTION "DOWN" SHALL TURN FAN ON. <br />261013 NEW 120/208V, 3PH, 4W PANEL "LP-6" TO BE RECESSED MOUNTED IN NEW WORK <br />AREA. SEE ONE -LINE DIAGRAM AND PANEL SCHEDULE ON E-510 FOR MORE <br />INFORMATION. COORDINATE WITH WALGREENS PROJECT MANAGER FOR EXACT <br />LOCATION OF PANEL PRIOR TO ROUGH -IN. <br />261014 ONE (1) 20A, 120V,1PH CIRCUIT FOR GFCI DUPLEX RECEPTACLE MOUNTED AT T-6" <br />A.F.F. <br />261015 PROVIDE A 20A,120V,1PH CIRCUIT (1500" DEDICATED CIRCUIT FOR ELECTRIC <br />WATER HEATER, <br />EWH-1. REFER TO PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. <br />261016 PROVIDE A 30A-208V,1 PH CIRCUIT AND A 30Al2P NEMA 3R DISCONNECT SWITCH FOR <br />MECHANICAL/PLUMBING EQUIPMENT. <br />261017 PROVIDE 20A CIRCUIT TO GFCI RECEPTACLE AND TAYMAC NO.20510 SAFETY <br />OUTLET ENCLOSURE (RAINTITE WHILE IN USE) OR PASS & SEYMOUR <br />"WEATHERPROOF WHILE -IN -USE COVER" ON ROOF FOR MAINTENANCE OF <br />EQUIPMENT. REFER TO NEC ARTICLE 210-63. <br />261018 PROVIDE A 15A-208V,1 PH CIRCUIT AND A 15Al2P DISCONNECT SWITCH FOR FOR <br />INDOOR HEAT PUMP UNIT. <br />261019 E.0 SHALL PROVIDE AND INSTALL ONE NEMA 5-20R DUPLEX RECEPTACLES AT BOTH <br />(2) <br />STOREFRONT SOFFITS FOR PSC WINDOW LIGHT BOXES (AS REQUIRED). CONNECT <br />DUPLEX <br />RECEPTACLE TO A SPARE 20A,120V CONTROLLED CIRCUIT. UTILIZE EXISTING <br />NEAREST <br />AVAILABLE POWER SOURCE WHEN AVAILABLE. SEE KEY PLAN FOR LOCATION. <br />LIGHTING KEY NOTES <br />Key Value Keynote Text <br />26 50 01 EMERGENCY DRIVER TO BE CIRCUITED AHEAD OF ALL LOCAL SWITCHING. <br />26 50 02 OCCUPANCY SENSOR, PURCHASED THROUGH NATIONAL ACCOUNT(SEE <br />SCHEDULE ON DRAWING E-510). (LAYOUT OF OCCUPANCY SENSORS <br />SHOWN ON PLAN IS FOR LEVITON. CONTACT HUBBELL FOR THEIR <br />RESPECTIVE LAYOUT). MOUNT AT +42" AFF <br />26 50 03 CEILING OR WALL MOUNTED, EMERGENCY EGRESS LUMINAIRE "E". SEE SHEET E-510 <br />FOR DETAILS CIRCUIT AHEAD OF ALL LOCAL CONTROLS. <br />LEGEND <br />�0 LED LIGHTING - SEE DRAWING E-520 FOR LUMINAIRE SCHEDULE AND <br />DETAILS. <br />LED NIGHT/EMERGENCY LIGHT <br />LED FIXTURE WITH EMERGENCY DRIVER <br />TRACK LIGHTING <br />- O �C> DOWNLIGHT OR PENDANT FIXTURE <br />EXTERIOR LUMINAIRE (WALL MOUNTED) <br />�J} OUTLET (WATTAGE AND LOCATION AS NOTED) <br />EXIT LIGHT:'E' (CEILING MOUNTED WITH PENDANT) <br />EXIT LIGHT: 'E' (WALL MOUNTED) <br />SWITCH <br />SWITCH WITH PILOT LIGHT <br />SWITCH, 3-WAY <br />�;,., —� OCCUPANCY SENSOR SWITCH, ARROW INDICATES DIRECTION OF <br />RECEIVER (IF APPLICABLE) <br />POWER GENERAL NOTES <br />1. DIMENSIONAL HEIGHTS OF OUTLETS AND RECEPTACLES SHALL BE MEASURED FROM <br />FINISHED SALES AREA FLOOR TO THE CENTER OF THE OUTLET OR RECEPTACLE. <br />2. ALL RECEPTACLES SHALL BE GROUNDING TYPE. <br />3. FOR ALL RECEPTACLES FED FROM PANEL "LP-CR", PROVIDE A LABEL ON THE FACEPLATE <br />INDICATING PANEL "LP-CR" AND CIRCUIT NUMBER USING A P-TOUCH LABELING MACHINE. <br />4. ALL HVAC EQUIPMENT LISTED ON DRAWING M-610 TO BE INSTALLED BY MECHANICAL <br />CONTRACTOR. ALL CIRCUITS TO BE ON LOCK -ON BREAKERS. ALL COMPRESSORS SHALL <br />HAVE BUILT-IN MAGNETIC STARTERS AND DISCONNECTS. <br />5. PVC CONDUIT AND FITTINGS ARE ACCEPTABLE ONLY BELOW SUBBASE MATERIAL OF <br />GROUND BEARING FLOOR SLABS WHERE SUCH USE IS ACCEPTABLE TO THE AUTHORITY <br />HAVING JURISDICTION. CONDUIT SIZE TO BE IN ACCORDANCE WITH NEC (SEE <br />SPECIFICATIONS FOR ADDITIONAL INFORMATION). <br />6. CONDUIT SHALL BE ELECTRICAL METALLIC (STEEL) TUBING (EMT), RIGID STEEL (SIZE IN <br />ACCORDANCE WITH NEC), OR MC CABLE WHERE ALLOWED BY CODE. WHERE MC CABLE IS <br />USED, PROPER SECUREMENT AND SUPPORT (AT INTERVALS NOT EXCEEDING 6 FEET) SHALL <br />BE FOLLOWED PER NEC ART. 330. <br />7. ALL RECEPTACLES AND SWITCHES SHALL HAVE TWO (2) REVOLUTIONS OF ELECTRICAL TAPE <br />(SCOTCH 33+) OVER ALL THE TERMINALS TO PREVENT ACCIDENTAL CONTACT WITH THE <br />JUNCTION BOX OR OUTLET BOX. <br />8. DIMENSIONS ARE FROM FINISHED WALL. SEE ARCHITECTURAL DRAWINGS FOR WALL <br />THICKNESS. <br />9. ALL CONDUITS ROUTED ABOVE THE GENERAL SALES AREA SHALL BE RUN IN A NEAT AND <br />ORGANIZED FASHION EITHER PARALLEL OR PERPENDICULAR TO THE ROOF STRUCTURE. <br />10. ALL WALL MOUNTED JUNCTION BOXES LOCATED ABOVE THE GENERAL SALES AREA SHALL BE <br />MOUNTED NO LOWER THAN 14'-0" A.F.F., UNLESS OTHERWISE NOTED. <br />11. ALL RACEWAYS (INCLUDING CONDUITS, JUNCTION BOXES, TROUGHS, ETC.) LOCATED ABOVE <br />THE GENERAL SALES AREA SHALL BE PAINTED WITH FINISHES SELECTED BY ARCHITECT. <br />LIGHTING GENERAL NOTES <br />1. FOR LUMINAIRE SCHEDULE AND DETAILS REFER TO DRAWING E-510. <br />2. FOR ELECTRICAL PANEL SCHEDULES REFER TO DRAWINGS E-510 <br />3. LUMINAIRES INSTALLED IN CONTINUOUS ROWS SHALL BE GROUNDED WITH A CONDUCTOR ROUTED <br />FROM LUMINAIRE TO LUMINAIRE, (OR VIA QUICK -CONNECT TERMINALS) ATTACHED TO EACH WITH <br />GROUNDING LUG OR SCREW. ALIGNING CLIPS ARE NOT ACCEPTABLE. LUMINAIRE GROUNDING SHALL <br />BE INSTALLED IN COMPLIANCE WITH NATIONAL ELECTRICAL CODE, ARTICLE 410-44. <br />4. CONDUIT SHALL BE ELECTRICAL METALLIC (STEEL) TUBING (EMT), RIGID STEEL (SIZE IN <br />ACCORDANCE WITH NEC), OR MC CABLE WHERE ALLOWED BY CODE. WHERE MC CABLE IS USED, <br />PROPER SECUREMENT AND SUPPORT (AT INTERVALS NOT EXCEEDING 6 FEET) SHALL BE FOLLOWED <br />PER NEC ART. 330-30. <br />5. PROVIDE EMERGENCY LIGHTING TO MEET THE REQUIRED FOOT CANDLE LEVEL PER LOCAL CODE. <br />6. WHEN UL AND/OR ULEM ARE UTILIZED IN GYPBOARD CEILING, PROVIDE THE ASSOCIATED FLANGE <br />KIT. <br />7. LUMINAIRE BOL LOCATED IN THE STOCKROOM, TECH ROOM, & PASSAGE SHALL BE MOUNTED 14'-0" <br />A.F.F., UNLESS NOTED OTHERWISE. ATTACH TO ROOF SUPPORT DO NOT ATTACH TO THE METAL <br />ROOF DECK. <br />PATIENT CARE AREA NOTES <br />IN ALL PATIENT CARE AREAS, E.C. SHALL COMPLY WITH THE FOLLOWING <br />REQUIREMENTS: <br />1. PROVIDE AND INSTALL ALL WHITE "HOSPITAL GRADE" RECEPTACLES & FACEPLATES. <br />2. PROVIDE AND INSTALL REDUNDANT GROUND SYSTEM WITH BOTH GROUND WIRE AND METAL <br />CONDUIT SYSTEM GROUNDING. <br />3. WIRING FOR PATIENT CARE/SERVICE AREA SHALL COMPLY WITH NEC 517(NFPA 70) RELATIVE <br />TO "HEALTH CARE FACILITIES". <br />LEGEND <br />_ OUTLET (WATTAGE AND LOCATION AS NOTED) <br />FLOOR JUNCTION BOX (WATTAGE AND LOCATION AS NOTED) <br />0 STANDARD SINGLE RECEPTACLE <br />STANDARD DUPLEX RECEPTACLE <br />SURGE PROTECTIVE DEVICE (SPD) DUPLEX RECEPTACLE <br />FIRE ALARM HORN STROBE DEVICE <br />UTV TV BOX. COORDINATE AV REQUIREMENTS WITH OWNER PRIOR TO ROUGH -IN <br />HOMERUN <br />MULTI -OUTLET RACEWAY ASSEMBLY (PLUGMOLD) <br />}.. MOTOR <br />Lp NON -FUSIBLE SAFETY DISCONNECT SWITCH <br />FUSIBLE SAFETY DISCONNECT SWITCH <br />-9 c;iz FINAL CONNECTION TO EQUIPMENT <br />METER SOCKET <br />ETR EXISTING DEVICE/FIXTURE/EQUIPMENT/CONDUIT/WIRE TO REMAIN. <br />RM EXISTING DEVICE/FIXTURE/EQUIPM NT/r Or% T/WIRE TO BE RE O <br />c <br />.N <br />LO <br />❑ t� <br />-Q L6 <br />cco o <br />0) 0 coo <br />E -!d <br />CD <br />CU�IF <br />O N <br />0o0 <br />N <br />CU LL <br />L V V <br />:3 a � <br />En - <br />cE 0 <br />U " O 0 <br />i 30 <br />N mm� <br />c EaU <br />W m <br />���unurr <br />���%A �Y He r r1, <br />O <br />, <br />Tim d>;h HBdrick <br />�F <br />�r z <br />11110 <br />(Doo <br />r- <br />M <br />Q M M <br />a�Uv:a <br />;v '10 <br />U) U) cr) <br />C U 00 <br />ai t�LO 0--,6 <br />LL a v <br />ro = CCU N m <br />04U)I-LL <br />L <br />� <br />co <br />co <br />N <br />_ N <br />0 <br />o <br />cn <br />Q <br />N <br />� <br />Ln <br />Q <br />U <br />vi O� <br />N <br />r' <br />O <br />Z <br />co a? <br />c6 <br />co <br />aj <br />U <br />� <br />'0 <br />CD � <br />p <br />L <br />W <br />J <br />U- <br />M <br />U) <br />E M VED. In <br />RL EXISTING DEVICE/FIXTURE/EQUIPMENT/CONDUIT1WIRE TO BE RELOCATED. LO <br />M <br />RN EXISTING DEVICE/FIXTURE/EQUIPMENT/CONDUIT/W IRE IN NEW LOCATION <br />EXISTING ELEC RM <br />0 - Z <br />W <br />W <br />0 LU cu <br />Of (D ❑ <br />Q � Q M <br />6 <br />AREA OF WORK w <br />O fl- <br />a00 <br />a CN <br />1 <br />Z <br />❑ O <br />u rl Ir n u r <br />t� <br />� <br />o <br />o <br />_o <br />o <br />= <br />Z <br />Y <br />o <br />W <br />p o <br />?• <br />U <br />LLI <br />Q <br />W <br />Q <br />W CO <br />U n <br />a <br />2 <br />0 <br />IZ Q <br />E-1 11 <br />COPYRIGHT © 2018 WALGREEN CO <br />