6745-6755 Basswood Cir
Zephyrhills
>
Building Department
>
Building Plans
>
6745-6755 Basswood Cir
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:23:46 PM
Creation date
2/19/2025 8:56:38 AM
Metadata
Fields
Template:
Building Plans
Street #
6745-6755
Location
Basswood Cir
Contractor
Ryman Construction
Building Plans - Permit #
20946-20950
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DETAIL A- A <br />8'X16' CONCRETE COLUMN <br />WITH (2) #5 REBAR FROM <br />FOOTER TO LINTEL BLOCK <br />STANDARD 90 DEGREE BEND <br />WITH 25" LAP MINIMUM <br />DETAIL B- B <br />4' CONCRETE SLAB W/ 6X6 <br />10/10 WWF OR "FIBERMESH" <br />MIN 3000 PSI CONCRETE <br />' 24"X24"X24" CONCRETE FOOTER WITH <br />(8) #5 REBAR REINF MAT <br />I � <br />REBAR DETAIL <br />PIER POUTER DETAIL CORNER DETAIL - FOOTING AND <br />CORNER DETAIL - BOND BEAM FOUNDATION WALL REINFORCEMENT <br />AND WALL REINFORCEMENT <br />ACI 90 STANDARD <br />HOOK -EMBED <br />6' <br />= <br />J <br />L7 <br />Z <br />Ld <br />tU <br />0 <br />Z <br />0 <br />w <br />J <br />w <br />J <br />w <br />w <br />Z <br />62' <br />#5 VERTICAL WALL REINF❑RCING <br />IN GROUTED CELL TYPE 'S' MORTAR <br />'—BOND BEAM W/(1) #5 REBAR 8'X8'X16' CMU TYP, <br />DEC❑RATIVE CEMENTU❑US <br />FINISH #5 VERTICAL WALL REINFORCING <br />IN GROUTED CELL <br />MIN OVERLAP 25' <br />4'X4' INSPECTION PORT <br />FILLED CELL AT EACH FILLED CELL <br />TYPICAL <br />NOTE+ EXTEND <br />DECO FINISH 4' TO 6' L STANDARD 90 DEGREE BEND <br />BELOW GRADE `WITH 25' LAP MINIMUM <br />#5 DOWEL ACI STANDARD HOOK <br />E EN0W%IVT& H❑RIZ, REINFORCING <br />CONCRETE F❑OTING <br />REINFORCING REBAR <br />:SEE FOUNDATI❑N PLAN) <br />—1 25' MIN LAP j� <br />MASONRY WALL <br />FILLED CELL DETAIL <br />f ING <br />_ IN CORNER <br />22�//0II'H X 221))2'##W55 MONOLITHIC SLAB <br />❑NT3'(CHAIRSRTYPR CONT, <br />1 <br />TYPICAL MONOLYTHIC <br />FOOTING DETAIL E-E <br />#5 DOWEL HORIZ. REBAR <br />z BEAM REINFORCING <br />z <br />J E <br />DOWEL—LAPPED WITH <br />WALL REINFORCING <br />\`#5 CORNER REBAR 1 <br />GROUTED CELL 1 <br />NOTEi ALL LAPS SHALL BE 25' MINIMUM <br />F.F. <br />4' CONCRETE SLAB W/ MIN 3000 PSIRC❑NCRETESH6 <br />C6 MIL <br />� ED VAPOR BARRIER <br />CC❑MPACTT❑ E95- ❑61FIED <br />PROCTOR ASTM D1557) <br />TERMITE TREATED <br />BOTTOM OF FOOTER SHALL <br />BE 12' BELOW GRADE <br />(2) #5 REBAR CONT, <br />ON 3' CHAIRS TYP. <br />a <br />8'XB'X16' CMU TYP, WITH <br />#5 VERTICAL WALL REINFORCING <br />IN GROUTED CELL <br />MIN OVERLAP 25' <br />(2) #5 CONT. ON 3' <br />CHAIRS (TYP.) <br />�_'/-4'_l <br />TYPICAL INTERIOR <br />DETAIL D-D <br />W.W,F <br />�BERMESH <br />TYPICAL DROPPED SLAB <br />DETAIL C- C <br />6 x 6 W,W.F <br />OR FIBERMESH <br />N <br />WALL <br />ft <br />0 <br />I <br />a--1 <br />I hereby certify that I have reviewed this plan and found it to be in <br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition <br />David W, Smith, P,E, #53608 <br />NOTE. ■❑ INDICATES 1—#5 REBAR IN FILLED CELL FROM <br />F❑❑TING TO LINTEL <br />LOCATED AT EACH SIDE OF ALL WIND❑WS <br />AND DOOR ❑PENINGS, 6' ❑C MAXIMUM ❑THERWISE, <br />SEE F❑❑TING DETAIL <br />FLOOR PLAN <br />IERMITE PREVENTI❑N N❑TESL <br />1. A PERMANENT SIGN WITH IDENTIFIES TREATMENT PROVIDER <br />AND NEED FOR RE—INSP AND TREATMENT RENEWAL SHALL BE <br />PR❑VIDED, THE SIGN SHALL BE POSTED NEAR THE WATER HEATER <br />ELECTRICAL PANEL FBC 104.26 <br />2. TO ENABLE TERMITE INSPECTI❑N, THE DISTANCE, BETWEEN WALL <br />COVERING AND EARTH GRADE SHALL BE 6 INCHES MINIMUM, <br />EXCEPTION, C❑RRISION REISITANT METALS, CEMENTATIOUS FINISHES <br />APPLIED DIRECTLY TO FOUNDATION. <br />3, INITIAL TERMITE TREATMENT SHALL BE COMPLETED AFTER ALL <br />EXCAVATI❑N AND BACK FILL IS FINISHED, <br />4. SOILD DISTURBED AFTER THE INITIAL TREATENT SHALL BE <br />RE —TREATED, INCLUDING SPACES BOXED OR FORMED. <br />5. BOXED AREAS IN CONCRETE FLOORS AND FOR SUBSEQUENT <br />&M&EDTDEAEPLP MOHRTTPgLqTATSTTwIIICLLFOERShiSEP&MANENTBFORMS MUSTPBEMOFEATSIZE <br />AF%E TTHEHTREATRENTLIMINATE THE DISTURBANCE OF SOIL <br />6. MINIMUM 6 MIL POLYFILM MUST BE INSTALLED TO PROTECT <br />AGAINST RAINFALL DILUTION. RETREATMENT IS REQUIRED IF <br />OCTECEORADPANGT7,CNREOVRPUNMORTGR LOHE F❑UNDATI❑N <br />PERIMETER MUST BE REMOVED BEFORE EXYERI❑R SOIL TREATMENT. <br />8. ALL BUILDINGS ARE REQUIRED TO HAVE PRE -CONSTRUCTION <br />TREATMENT, <br />9. NO WOOD, VEGETATION STUMP, CARDBOARD, TRASH, ETC. SHALL <br />BE BURIED WITHIN 15 FEET OF ANY BUILDING OR PROPOSED <br />BUILDING. <br />10, AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST <br />BE REMOVED FROM WITHIN ONE FOOT OF THE BUILDING, THIS <br />INCLUDES ALL GRADE STAKES TIB TRAP BOXES, FORMS, OTHER <br />CELLULOSE CONTAINING MATERIAL. <br />11. A CERTIFICATE OF COMPLIANCE MUST BE PROVIDED TO THE <br />BUILDING DEPARTMENT BY A LICENSED PEST CONTROL COMPANY <br />BEFORE A CERTIFICATE OF OCCUPANCY WILL BE ISSUED. THE <br />CERTIFICATE OF COMPLIANCE SHALL STATE THE BUILDING HAS <br />RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF <br />SUBTERRANEAN TERMITES AND THAT THE TREATMENT IS IN <br />ACCORDANCE WITH THE RULES AND LAW OF THE FLORIDA DEPT, <br />OF AGRICULTURE AND CONSUMER SERVICE, <br />