My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6745-6755 Basswood Cir
Zephyrhills
>
Building Department
>
Building Plans
>
6745-6755 Basswood Cir
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:23:46 PM
Creation date
2/19/2025 8:56:38 AM
Metadata
Fields
Template:
Building Plans
Street #
6745-6755
Location
Basswood Cir
Contractor
Ryman Construction
Building Plans - Permit #
20946-20950
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M-8 <br />DETAIL 'B' <br />"6'^'6a DETAIL 'B' DETAIL 'B' DETAIL 'B' DETAIL 'B' �� LL <br />DETAIL 'B' <br />REINF❑RCING SCHEDULE & LOAD CAPACITIES <br />SAFE W❑RKING LOADS (PLF) <br />8' x 8' LINTELS <br />MARK <br />NO. <br />LINTEL <br />LENGTH <br />CLEAR <br />SPAN <br />LINTEL <br />TYPE <br />LINTEL <br />TOP <br />BARS <br />LINTEL <br />BOTTOM <br />BARS <br />GRAVITY SAFE LOAD <br />UPLIFT SAFE LOAD <br />SAFE LATERAL LOADS (PLF) <br />PLAIN <br />S❑LID <br />#5(1)U(0)L <br />S❑LID <br />#5(1)U(1)L <br />S❑LID <br />#5(1)U(0)L <br />#5(1)U(1)L <br />S❑LID <br />#5(2)U(1)L <br />8'x8' <br />(PLAIN) <br />8'x8' <br />(SOLID) <br />A BAR <br />B BAR <br />DETAIL A <br />DETAIL B <br />DETAIL C <br />DETAIL B & C <br />DETAIL D <br />M-4 <br />4'-6' <br />3'-2' <br />Precast <br />(2) #3 <br />(2) #2 <br />NONE <br />1343 <br />2165 <br />2165 <br />2608 <br />2608 <br />638 <br />1266 <br />M-7 <br />5'-10' <br />4'-6' <br />Precast <br />(2) #3 <br />(2) #3 <br />NONE <br />860 <br />1423 <br />1423 <br />1470 <br />1609 <br />543 <br />1105 <br />M-8 <br />6'-4' <br />5'-0' <br />Precast <br />(2) #3 <br />(2) #4 <br />NONE <br />740 <br />1283 <br />1283 <br />1216 <br />1405 <br />634 <br />1355 <br />M-11 <br />7'-6' <br />6'-2' <br />Precast <br />(2) #3 <br />(2) #4 <br />NONE <br />570 <br />991 <br />991 <br />825 <br />1082 <br />446 <br />938 <br />M-17 <br />ll'-4' <br />10'-0' <br />Precast <br />(2) #3 <br />(2) #5 <br />NONE <br />315 <br />567 <br />567 <br />317 <br />607 <br />198 <br />620 <br />M-22 <br />14'-8' <br />13'-4' <br />Prestressed <br />(2) #3 <br />(2) #4 <br />NONE <br />N.R. <br />480 <br />480 <br />243 <br />471 <br />N.R. <br />341 <br />j�ETAIL 'B' <br />REINF❑RCING <br />SCHEDULE & LOAD <br />CAPACITIES <br />SAFE W❑RKING <br />LOADS (PLF) <br />8' x 8' <br />RECESS DOOR HEADER <br />MARK <br />TOTAL <br />CLEAR <br />LINTEL <br />TOP <br />LINTEL <br />GRAVITY SAFE <br />LOAD <br />UPLIFT SAFE LOAD <br />S❑LID <br />S❑LID <br />S❑LID <br />S❑LID <br />NO. <br />LENGTH <br />SPAN <br />TYPE <br />BAR <br />BOTTOM BAR <br />LATERAL <br />SAFE LOAD <br />PLAIN <br />#5(1)U(o)L <br />PLAIN <br />S❑LID <br />#5(1)U(0)L <br />#5(1)U(1)L <br />#5(1)U(1)L <br />#5(2)U(1)L <br />A BAR <br />B BAR <br />DETAIL DA <br />DETAIL DB <br />DETAIL DC <br />DETAIL DB & DC <br />DETAIL DF <br />DETAIL DA <br />DETAILDB <br />D-4 <br />4'-4' <br />1 3'-0'1 <br />Precast <br />(2) #3 <br />1 (2) #2 <br />NONE <br />963 <br />1 1230 <br />1230 <br />1596 <br />1 1596 <br />785 <br />1386 <br />ENGINEERING SPECIFICATI❑NS: <br />1.) SAFE LOADS ARE TOTAL SUPERIMP❑SED ALLOWABLE LOADS. <br />2.) DESIGNER MAY EVALUATE CONCENTRATED LOADS FROM THE SAFE LOAD TABLES BY <br />CALCULATING MAX, RESISTING SHEAR AND MOMENT FOR THE LISTED LINTELS. <br />3.) SAFE LOADS LISTED ON ALL TABLES ARE IN UNITS OF POUND PER LINEAR FOOT, <br />GENERAL N❑TES1 <br />1.) CODES <br />1.1 FLORIDA BUILDING CODE 6TH EDITI❑N 2017 <br />1.2 BUILDING CODE REQUIREMENTS FOR REINF❑RCED CONCRETE (ACI 318-11). <br />13 AMERICAN S❑CIETY OF CIVIL ENGINEERS MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER <br />STRUCTURES (ASCE 7-10). <br />2.) CONCRETE: <br />2A CONCRETE C❑MPRESSIVE STRENGTH AT 28 DAYS1 <br />2.1.1 PRE —CAST W/STANDARD REINF❑RCEMENT-4000 PSI MIN, <br />212 PRE —CAST W/PRESTRESS REINFORCEMENT-6000 PSI MIN, <br />2.1.3. GROUT PER ASTM C476 — 3000 PSI W/ MAX, 3/8' AGGERATE, <br />2.2 REINF❑RCING BARS, <br />22A STEEL PLACED IN PRECAST LINTEL AT TIME OF <br />FABRICATI❑N ASTM A615 (GRADE 60) <br />22,2 STEEL IN LINTEL AND KNOCKOUT BLOCK (PLACED IN FIELD) <br />23 PRESTRESS STRANDS ASTM A416 7—WIRE, STRESS RELIEVED 270 <br />2,4 DETAIL REINF❑RCEMENT IN ACCORDANCE WITH ACI 315. <br />2,5 C❑NCRETING ❑PERATI❑NS SHALL COMPLY WITH ACI STANDARDS, <br />3,) MASONRY: <br />8' TO 11' SLUMP, <br />ASTM A615 (GRADE 40), <br />KSI <br />3,1 DESIGN AND C❑NSTRUCTI❑N SHALL CONFORM TO THE SPECIFICATI❑N OF THE NATI❑NAL <br />CONCRETE MASONRY ASS❑CIATI❑N AND ACI 530-11, <br />3.2 MINIMUM MASONRY UNIT STRENGTH; F'M 1500 PSI. <br />33 MORTAR SHALL BE TYPE S, <br />4.) STRUCTURAL: <br />4.1 SAFE LOAD VALUES ARE BASED ON LINTELS HAVING A BEARING OF 8' (WITH A MINIMUM <br />ACCEPTABLE BEARING OF 4' PER SECTI❑N 2101,3,1 OF FLORIDA BUILDING CODE 6TH EDITI❑N 2017 <br />4.2 FOR LINTELS THAT ARE GREATER THAN 14'-0' CLEAR SPAN THEY SHALL BE PR❑VIDED A <br />TEMPORARY SUPPORT AND THE TEMPORARY SUPPORT SHALL NOT BE REMOVED UNTIL 2 DAYS <br />AFTER GROUT PLACEMENT. <br />0o M-8 DETAIL 'B' <br />I <br />J <br />LINTEL PLAN <br />2' RECESS <br />•O�eee: <br />[ hereby certify that I have reviewed this plan and found It to be 1'rg;� <br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Editiow-01, <br />David W, Smith, P,E, #53608 ' <br />
The URL can be used to link to this page
Your browser does not support the video tag.