Laserfiche WebLink
STUCCO CASING PAn lnnTW <br />WEEP HOLES OVER <br />ELEV AT 8'-0" <br />T.O.M. <br />ELEV AT 0'-0" <br />1ST FLOOR FF <br />SHINGLE Rc <br />ELEV AT 8'-0" <br />T.O.M. <br />5/8" STUCCI <br />OVER CMU <br />ELEV AT 0'-0" <br />1 ST FLOOR FF <br />REAR ELEVATION A <br />1 /411 = 1'-0„ <br />ELEV AT 8'-0" _ <br />T.O.M. <br />FRONT ELEVATION A <br />3/8" = 1'-011 <br />1 <br />�2 5 <br />75/8" STUCCO <br />OVER CMU <br />-1 <br />io <br />ELEV AT 0'-0" <br />1ST FLOOR FF — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />RIGHT ELEVATION A <br />1 /411 = 1'-0" <br />ELEV AT 8'-0" <br />T.O.M. <br />75/8" STUCCO <br />OVER CMU <br />ELEV AT 0'-0" <br />1ST FLOOR FF <br />4 LEFT ELEVATION A <br />1A _ 1,-nog <br />r � <br />I <br />I <br />I I <br />I I <br />SHINGLE ROOF <br />7/8" STUCCO <br />OVER PLYWOOD <br />1 1 /4" TH K x 6" <br />STUCCO BAND <br />i <br />5/8" STUCCO <br />OVER CMU <br />ROOF FINISH <br />PER ELEVATION <br />ROOF SHEATHING <br />12 <br />5 MANUFACTURED <br />ROOF TRUSS <br />•p: <br />MTL DRIP EDGE <br />ALUMINUM WRAP <br />ALUMINUM SOFFIT <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />� �OVER A G DETAIL <br />ROOF FINISH PER <br />ELEVATION <br />ROOF SHEATHING <br />MANUFACTURED <br />ROOF TRUSS <br />METAL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINIUM WRAP <br />PER ELEVATION ALUMINUM <br />NOTE: REFER TO STRUCTURAL SOFFIT SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION. <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />6 OVERHANG DETAIL MAR 0 4 2013 <br />ti <br />BAND <br />5/8" STUCCO <br />FINISH <br />NOTE: 4 <br />FOAM TO BE USED ONLY WHEN <br />REQUIRED BY COMMUNITY <br />Virtual Review Assist, Inc. <br />SPECS. IF NOT, DETAIL TO BE - <br />BUILT W/ STUCCO Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />VARIES PER OPENING <br />I I 2" THICK <br />1" 2" <br />1-1/2" THICK <br />N 3 1 /2" <br />io <br />3" THICK <br />VARIES PER OPENING <br />FOAM BAND 8 ELEVATION DETAILS <br />7 AMU COLUMN DETAIL <br />4" 10" <br />N 4„ <br />2 LB EPS 2" 1" <br />9 BRACKET DETAIL <br />CV <br />M <br />N <br />N <br />0 <br />N <br />OD <br />N <br />\ C) <br />tto <br />ss <br />s's ; w <br />.� h.. ft <br />w <br />z <br />nN <br />> o � o <br />W L 100 U <br />0MS' 0 <br />%`.ram <br />Ln <br />�MM 2 <br />\% M w 0— U U() <br />� oU 8 <br />� o Q .� <br />�N <br />w 6'. < <br />n1 <br />W <br />7 <br />CQCN <br />L 0 C <br />r\ O "m <br />W <br />W <br />LLj uj w 0 F-- <br />w~ W (~zW <br />Ir�� LL00x <br />< <br />Q F— <br />U <br />J�O?of <br />ow 0,0-j0 <br />��O<ZLLLL OmOZQ¢ <br />��y O <br />v <br />(/1 � <br />O <br />Z <br />��a>zYo�_ZLL�Qp>-a <br />�<<0W ZIz 00d <br />Qow g~� EYDQQ Q <br />o � 0 Q z <br />� Q o F_ LL <br />if <br />O <br />O <br />Z CV <br />O� <br />U) Z) ti <br />z <br />F- cM O <br />Q (1) M � <br />w <br />W�rZ- <br />W <br />1--LyacM <br />Of IL — <br />00 <br />Z U f`t-- <br />W <br />W <br />JC) <br />O <br />A <br />co <br />IT <br />I <br />I <br />I <br />I <br />I <br />I <br />! <br />o <br />N <br />o <br />�- <br />O <br />N <br />(W <br />Oco <br />O <br />N <br />CDC::) <br />o <br />o <br />I <br />I <br />z <br />' <br />O <br />Nw <br />O <br />O <br />I <br />LO <br />c- <br />N <br />M <br />i <br />Z I- <br />¢Z <br />w <br />O <br />Z <br />}' <br />O <br />W <br />U_ <br />zz <br />woo <br />Lo <br />F- <br />O <br />UU�5 <br />Dz5 <br />ow- <br />oho <br />-� <br />Q <br />C:) <br />Z <br />a -a <br />1 <br />w a <br />�Ln} <br />(7 <br />�I- <br />V <br />T� <br />— <br />O~O <br />ZO= <br />W <br /><�Z) <br />O <br />O <br /><w <br />U <br />Z <br />aZ� <br />U <br />< <br />00� <br />F— W <br />o: <br />Z <br />A5 <br />z <br />z <br />w <br />J <br />W <br />�� <br />0 <br />N <br />0 <br />T_ <br />LAST PLOT DATE <br />N <br />• <br />November 28, 2022 <br />z� <br />EXTERIOR <br />-- <br />ELEVATIONS A <br />