My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36495 Smithfield Ln
Zephyrhills
>
Building Department
>
Building Plans
>
36495 Smithfield Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 10:51:51 PM
Creation date
2/19/2025 9:10:30 AM
Metadata
Fields
Template:
Building Plans
Street #
36495
Location
Smithfield Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A/C <br />DICONNECT <br />WP <br />GFI <br />GI <br />I <br />I PORCH <br />I <br />I <br />I <br />I <br />L___ _— <br />ELECTRICAL PLAN (ELEVATIONS A & B <br />1 /4„ = 1'-0'1 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS -WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN 44" AFF <br />BATHROOM 39" AFF <br />LAUNDRY ROOM 36" AFF <br />EXTERIOR WATERPROOF 12" AFF <br />GARAGE GENERAL PURPOSE 42" AFF <br />RANGE 2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />M 0 4 2023 <br />� f <br />Virtual Review Assist, inc. 7 <br />Plans Review completed and approved ' <br />for compliance with the 2020 FBC 7th Editio►v <br />PX9300 <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />NEMA 1 <br />0 #12 copper to 20 amp ckts <br />200 AMP <br />JO #10-2 copper to WH <br />00 #10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />_j <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steal <br />TYPICAL 150-200 AMP ELECTRICAL <br />RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH ° <br />4 1 /2" <br />DOORJAMB DUPLEX 19 <br />OUTLET c%> <br />TRIM <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o Z <br />kS �' <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />-6 SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />-64-2 4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />—0 DIMMER SWITCH AT 36" <br />-{] PUSH-BUTTON DOORBELL <br />-�- CLG MNT LT FIXTURE <br />-}- CLG MNT PREWIRE - FIXTURE BY OWNER <br />'E SURFACE MNT FIXTURE <br />-- WALL MNT FIXTURE <br />NOTE: <br />0l 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />0 50W MR16 4" LOW VOLTAGE OWNER <br />08 50W PAR20 NFL 4" MINI ROUND RECESS <br />050W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />SMOKE DETECTOR <br />rU-18= UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 — UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />— D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />9-124:;R 24" VANITY LIGHTING <br />36 :7mP 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />(, EXHAUST FAN <br />p_A DOUBLE FLOOD LIGHT W/ COVERS AND <br />L� 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />1= MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />14 CEILING RETURN AIR <br />ED A/C REGISTER <br />® THERMOSTAT <br />021 SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />N a) `0 E <br />0 <br />b <br />s` o <br />� ai <br />pM00 <br />V M <br />M .�. <br />(n �% -O O y T <br />E �o <br />O 2 <br />O <br />Ll S N Q <br />V/ <br />•N w p N it <br />Q cv <br />n ` C <br />W L 0o E� <br />h O n m <br />W <br />W <br />0L a> W0 <br />F-LLJ ~ Q Of< zzOf <br />of�- <br />Q <br />Q I- <br />1- <br />J�o�W')LLUOQLL <br />a x Ix o o <br />cJun°W�oZoEoomZzaU <br />J0 <br />< <br />0 <br />Z <br />w01 >WLuWPWLL W<0jr_, <br />aowo�la-�zMWYOQ0�a <br />z <br />oQ o 0 o<<W <br />LL <br />O <br />Z N <br />O� <br />D ti <br />z <br />0 F cM O <br />Q (n M L0 <br />a- (/) <br />LL <br />2 U)z <br />ti <br />< W Lq <br />M <br />I 0�0 <br />Z U <br />Z <br />W <br />WO <br />J O <br />A <br />I <br />I <br />I <br />I <br />I <br />O <br />O <br />O <br />00 <br />N <br />O <br />N <br />N <br />_O <br />O <br />_ <br />O <br />N <br />r- <br />O <br />Z <br />O <br />e- <br />O <br />' <br />O <br />N <br />o <br />0 <br />0 <br />Lo <br />w <br />N <br />ri <br />I <br />I <br />I <br />I <br />WQ <br />z <br />w <br />�zz <br />0) <br />O <br />W <br />Woo <br />�z> <br />H <br />ow- <br />�— <br />0 <br />Z <br />f- <br />a a <br />Q <br />Ln <br />w <br />(n~W <br />T� <br />O <br />■ <br />W <br />W <br />>.X0 <br /><�� <br />00 <br />Q <br />O <br />ZWO <br />C(� <br />w LL. <br />z <br />az <br />�Z <br />z <br />�� <br />U <br />0 <br />_o <br />W <br />z <br />A6 <br />z <br />w <br />W <br />J <br />O <br />r <br />04 <br />LAST PLOT DATE <br />N <br />• <br />November 28, 2022 <br />z <br />- <br />J <br />ELECTRICAL PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.