My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36508 Smithfield Ln
Zephyrhills
>
Building Department
>
Building Plans
>
36508 Smithfield Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 12:07:21 AM
Creation date
2/19/2025 9:10:53 AM
Metadata
Fields
Template:
Building Plans
Street #
36508
Location
Smithfield Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
5965
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A/C <br />DISCONNECT <br />WP <br />GFI / <br />GFI GFI PANTRY <br />ao <br />o <br />'4 '4 <br />GFI <br />GFI AT <br />TV _ 30" A F. F. <br />' DW <br />HDMI GFI <br />6'-1" <br />_TO <br />'4; <br />I° <br />LIVING/ I ° <br />ROOM* 0 IF <br />GFI AT F.F.. <br />30" A.. <br />5'-8" 4'-3" <br />Ilk <br />F <br />1. KITCHEN GI <br />- W <br />A <br />GFI <br />_ A - <br />co <br />DINING 4 10, GFI <br />ROOM UTIL TY <br />'PWDR GFI <br />wo <br />BATHS / <br />O <br />f ELEC <br />PANEL <br />AV <br />�I <br />TWO CAR GARAGE ' <br />i <br />CDGFI 48 <br />a) <br />0 <br />0 2ND cs iv <br />LR ELEC ', GFI GFI <br />6�110V CLG <br />I <br />\\II MNT. <br />---------i--- OUTLET--- <br />AVI i I <br />o I <br />CID <br />I CDI GFI <br />I WP N <br />,Q✓ I i I <br />4'-8" <br />I <br />ENTRY <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION A <br />1 /4" = 1'-0" <br />7—�,ii ITI—Ir -___-._[---T- - ____ - <br />ELEC <br />METER <br />T - <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />Dj KITCHENS -WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS -WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE � <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES &DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BEAT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION &SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A. F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights &outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer0 <br />METER 2/0 or 4!0 SER Alu <br />MAIN <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />�--- 4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />T <br />NTS <br />MAR 2 5 2023 <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 F8C 7#h Edition <br />by Debra Anne Kdahr PX2300 <br />I11 1 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />r <br />SWITCH ° <br />4 1/2" <br />DOOR JAMB DUPLEX <br />OUTLET ri <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />k <br />SMOKE DETECTOR. LOCATION: <br />WALL <br />oz <br />SMOKE DETECTOR <br />1'-0" <br />MIN. <br />WALTERNATE <br />- <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" -TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION &TYPE <br />a TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" -WIRE FOR <br />CABLE &SATELLITE <br />QSTRUCTURED WIRE OUTLET <br />-tom- SWITCH AT 36" <br />� 3 WAY SWITCH AT 36" <br />- <br />4 WAY SWITCH AT 36" <br />-p PUSH BUTTON FOR GARAGE DOOR OPENER <br />-o DIMMER SWITCH AT 36" <br />--� PUSH-BUTTON DOORBELL <br />{A} CLG MNT LT FIXTURE <br />-{�- CLG MNT PREWIRE -FIXTURE BY OWNER <br />-�- SURFACE MNT FIXTURE <br />-�- WALL MNT FIXTURE <br />NOTE: <br />C TUB/SHOWERND OPALEX - CANS MAY BE <br />4� 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />C APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE .OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />�o� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIX <br />Cos SMOKE DETECTOR <br />C SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STF <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STF <br />=D-24= DOUBLE 24" FLUOR ST <br />= U-36 = UNDER CABINET 36" <br />= S-33 = SINGLE 36" FLUOR STF <br />= D-36 = DOUBLE 36" FLUOR ST <br />S-48 — SINGLE 48" FLUOR STF <br />D-48 DOUBLE 48" FLUOR ST <br />24 24"CLG MNT WRAPPEE <br />48 48"CLG MNT WRAPPEE <br />F-724:R 24" VANITY LIGHTING <br />R;F 36 ;;R 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUSTFAN <br />DOUBLE FLOOD LIGHT W/ COVEF <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5-0" ABN <br />CEILING MNT SPEAKER <br />03 CHIMES (DELETE W/ INTERCOM) <br />3= MASTER STATION <br />_MQ ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />A/C REGISTER <br />OT THERMOSTAT <br />M SECURITY PAD <br />LO <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WIT <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />FIXTURES SHOWN ARE FOR LOCATION PURPC <br /><oo <br />, <br />N <br />N <br />0 <br />N <br />N <br />T <br />. z 1 c« <br />z <br />�4 <br />s� <br />E <br />z <br />Q <br />LO N E <br />0 <br />� <br />0 <br />�o C Q <br />� <br />ILLU <br />LIJ L'I�U�j�Q <br />W <br />p�zW�a w <br />Q <br />aa X J z� <br />3 Q z2° 0 O Q O <br />_U <br />< <br />c�W°�W°z°Woo�in°zz�� <br />J <br />U' z <br />0 <br />a° <br />W�Zw� <br />��g�O <br />nLL <br />OQ� <br />p�°¢ <br />E5QZ�a <br />W a <br />O � a u. <br />O <br />Z W <br />O� <br />���MO <br />Q w M � <br />I—� <br />
The URL can be used to link to this page
Your browser does not support the video tag.