Laserfiche WebLink
SECOND FLOOR ELECTRICAL PLAN (A & B <br />1 /4„ = 1'-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST S FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO 13E GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />MAR 2 5 MI <br />VR/ <br />Virtual Review Assist, Inc. <br />Plans Review completed and approved <br />for compliance with the 2020 0 BC 7th Edition$ <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH- <br />4 1/2" <br />DOORJAMB <br />DUPLEX <br />OUTLET r> <br />TRIM <br />o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />o Z <br />S <br />SMOKE DETECTOR <br />V-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />& 110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />Ir <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />HORIZONTAL <br />AT 12" - TOP PLUG IS HOT <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />QSTRUCTURED WIRE OUTLET <br />e SWITCH AT 36" <br />co <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />—0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />+ CLG MNT PREWIRE - FIXTURE BY OWNER <br />+ SURFACE MNT FIXTURE <br />-�- WALL MNT FIXTURE <br />NOTE: <br />- TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />C 50W PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />C 50W MR16 4" LOW VOLTAGE OWNER <br />C 50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />Cos SMOKE DETECTOR <br />O SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />CS-182 SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />= U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />F-724:R 24" VANITY LIGHTING <br />F-r—= 36 :FFR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />C� DOUBLE FLOOD LIGHT W/ COVERS AND <br />V 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />`.J ELEC PANEL <br />El VACUM OUTLET AT 12" <br />7A1 CEILING RETURN AIR <br />® A/C REGISTER <br />OTT` THERMOSTAT <br />IM SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES, <br />N <br />N <br />0 <br />N <br />_= <br />T <br />04 <br />00 <br />a <br />"., <br />is <br />" <br />Q <br />� J <br />2 <br />O <br />W <br />0 <br />z <br />Vn,) <br />L <br />C 0 <br />W <br />L U <br />} M 1 <br />__ <br />co`u a <br />M <br />n' r <br />W i L <br />W ` 00 <br />o°o o< <br />�= <br />•nV) <br />i U�� <br />W <br />V W QN <br />L 0O EZ U <br />a <br />W <br />oL W W2�O <br />F- � J � Z <br />¢ <br />� z <br />fn <br />V <br />Q <br />LLI <br />U <br />Of�-_jQ0QaLLUOoJO <br />J !n 2 0 <br />Z LL - Z <br />J — <br />H¢ <br />Q <br />0¢ u. <br />Z= <br />Q <br />J <br />U) 0 <br />Z <br />U)WdWOWOWO0' <br />-joQILL <br />WW O_Luz <br />CCL <br />L <br />o< <br />z < <br />O a <br />u. ¢ O ¢ ti <br />O <br />O <br />Z N <br />O W <br />U ti <br />O <br />M <br />QWM� <br />2 w - <br />ti <br />z <br />< W < Lq <br />_M <br />O <br />Z U <br />I,I,I <br />W <br />J O <br />O <br />N <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />O <br />o <br />0 <br />0 <br />0 <br />0 <br />O <br />o a <br />e- <br />C <br />o <br />N <br />o <br />i <br />I <br />I <br />Z <br />O <br />N <br />`� <br />w <br />o <br />0 <br />0 <br />0 <br />o <br />I <br />I <br />i <br />> <br />e- <br />N <br />M <br />tt <br />L6 <br />Cr <br />Z~ <br />ZZ <br />W <br />¢W <br />O <br />W <br />cioo <br />O <br />�Z <br />F_ <br />O <br />o�� <br />Q <br />Z <br />aira <br />�WI¢— <br />m F W <br />N <br />I-0 <br />Zoo <br />W <br />F� <br />CY) <br />Q <br />0 <br />z�0 <br />O <br />0a- <br />z <br />z <br />U <br />_3 <br />0 <br />o- <br />MMO <br />W <br />Z <br />� <br />¢ <br />z <br />z <br />W <br />W <br />J <br />P_ <br />N <br />0 <br />Q <br />O <br />LAST PLOT DATE <br />December 14, 2022 <br />Z <br />O <br />2ND FLOOR <br />ELECTRICAL PLAN <br />Lf ;ILI IIBv ;L�. ie d7, _ii it ,,i: l� <br />