My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
5915 Gall Blvd (3)
Zephyrhills
>
Building Department
>
Building Plans
>
5915 Gall Blvd (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 12:48:20 PM
Creation date
2/19/2025 9:15:37 AM
Metadata
Fields
Template:
Building Plans
Street #
5915
Location
Gall Blvd
Contractor
W. Barnett
Building Plans - Permit #
3449
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES: <br />ISSUED FOR: REVIEW <br />11.01.2021 <br />EXISTING PANEL "A" <br />MCB: 200 A.I.C.: EXISTING PHASE: 3, S/N WIRE: 4 BLDG: VIBES SMOKE SHOP <br />MLO: N/A VOLTS: 120/208 V MTD: RECESSED <br />DESCRIPTION OF LOAD <br />BRKR <br />KVA PH LOAD <br />CIR <br />NO <br />PHASE <br />CI <br />N <br />KVA <br />PH LOAD <br />BRKR <br />DESCRIPTION OF LOAD <br />AMP <br />P <br />0A <br />0B <br />0C <br />A <br />B <br />C <br />0A <br />OB <br />0C <br />P <br />AMP <br />H <br />RTU-1 <br />35 <br />3 <br />3.96 <br />1 <br />■ <br />2 <br />0.70 <br />1 <br />20 <br />DF & RECEPT. <br />R <br />3.96 <br />3 <br />■ <br />4 <br />0.36 <br />1 <br />20 <br />WINDOW RECEPT. <br />R <br />3.96 <br />5 <br />■ <br />6 <br />SPACE <br />W <br />WATER HEATER <br />25 <br />212.25 <br />17 <br />■ <br />8 <br />0.18 <br />1 <br />20 <br />ROOF RECEPT. <br />R <br />2.25 <br />9 <br />• <br />10 <br />0.72 <br />1 <br />20 <br />BACKROOM RECEPT. <br />R <br />L <br />SIGN <br />20 <br />1 <br />1.20 <br />11 <br />■ <br />12 <br />SPACE <br />L <br />INTERIOR LIGHTS <br />20 <br />110.13 <br />13 <br />■ <br />14 <br />0.36 <br />1 <br />20 <br />POS RECEPT. <br />R <br />L <br />INTERIOR LIGHTS <br />20 <br />1 <br />0.26 <br />15 <br />■ <br />16 <br />0.36 <br />1 <br />20 <br />SALES RECEPT. <br />R <br />L <br />DISPLAY LIGHTS <br />20 <br />1 <br />1.50 <br />17 <br />■ <br />18 <br />SPACE <br />L <br />EXISTING EXTERIOR LIGHT <br />20 <br />110.101 <br />19 <br />■ <br />20 <br />0.36 <br />1 <br />20 <br />RESTROOM RECEPT. <br />R <br />I <br />TIME CLOCK <br />20 <br />11 <br />10.10 <br />21 <br />■ <br />22 <br />SPACE <br />L <br />DISPLAY LIGHTS <br />20 <br />1 <br />1.20 <br />23 <br />124 <br />SPACE <br />25 <br />■ <br />26 <br />27 <br />■ <br />28 <br />29 <br />■ <br />30 <br />31 <br />■ <br />32 <br />33 <br />■ <br />34 <br />35 <br />• <br />36 <br />37 <br />■ <br />38 <br />39 <br />■ <br />40 <br />41 <br />■ <br />42 <br />I TOTAL 1 6.441 6.57 17.86 1 <br />LEGEND <br />L <br />LIGHTING <br />R <br />RECEPTACLE <br />W <br />WATER HEATER <br />I <br />I MISCELLANEOUS <br />H <br />I AIR CONDITION/HEATING <br />LOAD ANALYSIS <br />LOAD <br />VOLT <br />CONNECTED (KVA) <br />FACTOR <br />DEMAND (KVA) <br />LIGHTING <br />120 <br />4.39 <br />125% <br />5.49 <br />CONV. OUTLETS <br />120 <br />3.04 <br />100% <br />3.04 <br />WATER HEATER <br />240 <br />4.50 <br />65% <br />2.93 <br />AIR CONDITION <br />208 <br />11.88 <br />100% <br />11.88 <br />MISCELLANEOUS <br />120 <br />0.10 <br />100% <br />0.10 <br />OTHERS <br />--- <br />--- <br />100% <br />--- <br />TOTAL <br />23.91 <br />23.44 <br />120/208. 30 POWER SUPPLY CALCULATIONS: <br />1. TOTAL DEMAND LOADS <br />= 23.44 KVA <br />2. DEMAND CURRENT/O <br />= 65 AMPS @ 120/208V,30 <br />3. EXISTING PANEL "A" <br />= 200 AMP MCB, 120/208V, 30, 4W. <br />4. EXISTING POWER SUPPLY <br />= 200 AMP, 120/208V, 30, 4W. <br />11.60 1 1.441 0.00 I TOTAL I <br />OA <br />OB <br />OC <br />TOTAL CONNECTED KVA <br />8.04 <br />8.01 <br />1 <br />7.86 <br />67 <br />67 <br />1 65 <br />TOTAL CONNECTED AMPS <br />(1)(2) <br />(1) PROVIDE LOCK TAB AT THESE BREAKERS IN "ON" POSITION. <br />(2) ROUTE THIS CIRCUIT WITH ISO. GROUND CONDUCTOR. <br />(3) ROUTE THESE LIGHT CIRCUITS THROUGH TIME CLOCK. <br />I <br />EXTERIOR TENANT <br />SPACE <br />I <br />EXIST. 4-#250 MCM, AL, <br />1-#4, AL, GRND, <br />3 2 <br />IN 2" C. FROM UTILITY <br />TRANSFORMER I EXIST. 4-#250 MCM, AL, <br />1-#4, AL, GRIND, <br />IN 2" C. <br />7 DAY, 24-HOUR <br />f-El TIMECLOCK <br />I <br />1 EXIST. <br />D I i I I PANEL <br />EXIST. METER SOCKET, <br />COORDINATE WITH UTILITY M I I J „A" 5 <br />COMPANY TO INSTALL NEW ELECT. I - 200 AMP O <br />METER FOR EXISTING 200A, 120/ I I I <br />208V, 30, 4 W SERVICE MCB <br />L- r- J I I 120/208V I O <br />L 3PH, 4W <br />I <br />I <br />I <br />I <br />EXIST. GROUNDING-4 <br />0 - I <br />I <br />i <br />RISER DIAG. NOTES: <br />Ol VERIFY EXISTING METER SOCKET IS IN COMPLIANCE WITH RISER DIAGRAM AND N.E.0 APPLICABLE CODE. <br />OVERIFY EXISTING GROUNDING SYSTEM IS IN COMPLIANCE WITH RISER DIAGRAM AND N.E.C. STD. #250 REQUIREMENTS. <br />OVERIFY EXISTING FEEDERS AND CONDUITS ARE IN COMPLIANCE WITH THE RISER DIAGRAM. <br />4 VERIFY AND REUSE EXISTING PANEL "A" IN COMPLIANCE WITH THE RISER DIAGRAM. ALL BREAKERS IN PANEL SHALL BE BOLTED TYPE. <br />5 CONTRACTOR SHALL INSTALL A COMPLETE TYPEWRITTEN IDENTIFICATION DIRECTORY CARD FOR ALL MAIN AND BRANCH CIRCUITS IN THE <br />PANEL DOOR (ELECTRICAL PANEL BOX.) <br />EXISTING ELECT. POWER RISER DIAGRAM <br />1. CONTRACTOR SHALL REVIEW THE SPECIFICATIONS, GENERAL NOTES, KEY NOTES, ELECTRICAL PLANS <br />AND THE LANDLORD DESIGN CRITERIA BEFORE BIDDING AND STARTING ANY CONSTRUCTION WORK. <br />2. ALL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE DESIGN DOCUMENTS, LANDLORD <br />DESIGN CRITERIA AND N.E.C. REQUIREMENTS. <br />3. CONTRACTOR SHALL VERIFY EXISTING POWER DISTRIBUTION CENTER AND REUSE EXISTING POWER <br />SUPPLY TO THE SPACE IN COMPLIANCE WITH THE RISER DIAGRAM. THIS WILL INCLUDE ELECTRIC <br />METER, FUSED DISCONNECT SWITCH, POWER SUPPLY FEEDER AND POWER PANEL. <br />4. CONTRACTOR SHALL PROVIDE NEW WIRING AND BREAKERS FOR ALL LOADS AS SHOWN ON PANEL <br />SCHEDULES AS REQUIRED. <br />5. PULL STRINGS SHALL BE PROVIDED IN ALL EMPTY CONDUIT. FOR TELEPHONE AND LOW VOLTAGE <br />SYSTEM. <br />6. INTERIOR TELEPHONE AND DATA WIRING SHALL INCLUDE FURNISHING AND INSTALLING ALL <br />TELEPHONE AND DATA JACKS, AND COVER PLATES AS REQUIRED. COORDINATE WITH THE TENANT. <br />7. LABEL ALL ELECT. EQUIPMENT WITH ENGRAVED BAKELITE NAMEPLATE OR EMBOSSED PLASTIC NAME <br />STRIP. LABEL ALL PANELS AS SHOWN ON THE RISER DIAGRAM. <br />8. FURNISH NEW TYPE WRITTEN CIRCUIT DIRECTORY CARDS FOR EXISTING PANELS. LIST ALL USED AND <br />SPARE CIRCUITS. <br />9. CONTRATCOR SHALL PROVIDE NEW DISCONNECT SWITCHES FOR RTU-1 AS DESCRIBED IN KEY NOTE #8. <br />COORDINATE WITH MECHANICAL PLANS AND PROVIDE DUCT SMOKE DETECTOR IF REQUIRED. <br />10. ALL ELECTRICAL DEVICES AND EQUIPMENT SHALL BE EFFECTIVELY GROUNDED IN ACCORDANCE WITH <br />N.E.C. REQUIREMENTS. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE GREEN INSULATED GROUND <br />WIRE IN EACH CONDUIT RUN. <br />11. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELECTRICAL CONNECTIONS UNLESS NOTED OTHERWISE. <br />12. CONTRACTOR SHALL BE RESPONSIBLE FOR COMMUNICATION WITH THE PROPERTY OWNER'S PERSONNEL <br />TO REVIEW CONTRACT DOCUMENTS PRIOR TO INSTALLATION. <br />13. CONTRACTOR TO SEAL ALL WALL PENETRATIONS IN AN APPROVED MANNER TO INSURE THE FIRE RATING <br />INTEGRITY OF THE INVOLVED AREAS. <br />14. COORDINATE FINAL INSTALLATION REQUIREMENTS WITH PROPER AUTHORITIES. <br />15. CONTRACTOR, UPON COMPLETION OF HIS WORK, SHALL BE RESPONSIBLE TO PROVIDE ANY AND ALL <br />CERTIFICATIONS. <br />16. ALL CONDUIT RUNS ABOVE CEILING SHALL BE PARALLEL OR PERPENDICULAR TO THE COLUMN LINES. <br />17. ALL CABLES AND WIRES SIZES SHALL COMPLY WITH N.E.C. TABLE 310-16. MINIMUM SIZE OF <br />CONDUCTOR SHALL BE #12 AWG CU. NO. 10 WIRES SHALL BE USED IN PLACE OF #12 FOR CIRCUITS <br />LONGER THAN 75 FEET FROM PANEL TO LOAD. ALUMINUM CONDUCTOR SHALL NOT BE PERMITTED. WIRE <br />INSULATION SHALL BE THHN OR THWN. <br />18. ALL INTERIOR WIRING SHALL BE CONCEALED AND IN GAL. STEEL OR EMT CONDUITS AND IN <br />COMPLIANCE WITH THE N.E.C. <br />19. CONTRACTOR MAY USE FLEXIBLE CONDUIT FROM JUNCTION BOX TO THE LIGHTING FIXTURE, BETWEEN <br />LIGHTING FIXTURES, AND TO OTHER DEVICES PROVIDED THE LENGTH OF THE FLEXIBLE CONDUIT IS <br />NOT MORE THAN 6 FEET. <br />20. BX, ROMAX, MC OR ANY OTHER ARMORED OR METAL -CLAD WIRING SHALL NOT BE PERMITTED. <br />BEFORE PERMITTING OR START OF CONSTRUCTION: <br />1. TENANT TO ACQUIRE LANDLORD WRITTEN APPROVAL OF ALL PROPOSED ALTERATIONS. <br />2. CONTRACTOR TO VERIFY ALL EXISTING DIMENSIONS AND ELEVATIONS. <br />3. CONTRACTOR TO COORDINATE ROUGH WINDOW/ DOOR OPENINGS SIZE W/ MFR SPEC: <br />c <br />m <br />Z <br />F <br />a <br />U <br />N <br />Ld <br />0 <br />11111111 <br />U) <br />w <br />J <br />D <br />0 <br />Lu <br />U) <br />J <br />W <br />z <br />Q <br />J <br />Q <br />_U <br />U <br />J <br />w <br />Lo <br />1'--o <br />� U <br />co <br />I <br />I) <br />�z <br />cta w <br />I d <br />r- O <br />�a <br />m <br />0 <br />w <br />z <br />W <br />z <br />w <br />U <br />Q <br />1.4 <br />ti <br />ti <br />O <br />E+ <br />V1 <br />O <br />z <br />P., <br />O <br />E- <br />U <br />a; <br />1.4 <br />a <br />� m <br />w <br />O e� <br />I._4 <br />o <br />W <br />IL <br />co <br />JOB. N0.21040 <br />GICIE <br />COA. NO.29116 <br />MAZEN IWARIE, PE. <br />L. P 60166) <br />r <br />1J <br />E2.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.