Laserfiche WebLink
BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />TYPICAL AT ALL WOOD <br />TO MASONRY <br />TRANSITIONS <br />2X <br />FRAMING <br />FLOOR <br />-SHEATHING PER <br />SPEC. <br />RIM BOARD <br />REFER TO <br />-STRUCT DWGS.� <br />60 MIN. <br />GRADE D <br />�- PAPER <br />BACKED <br />LATH <br />I <br />I :� <br />WALL <br />SHEATHING <br />j j <br />Z <br />.. i <br />.. <br />7/8" 3-COAT <br />I <br />STUCCO <br />Lo <br />_ SHEATHING <br />FLUSH WITH <br />I *- <br />BLOCK WALL <br />j <br />MID -WALL WEEP <br />;REED/EXPANSION <br />I I <br />JOINT <br />I I <br />6" SELF ADHERED <br />FLASHING <br />I I <br />5/8" <br />I I <br />CEMENTITIOU <br />COATING <br />BUILDING FELT <br />- ON TOP OF <br />CONC. BLOCK <br />UNDER FLOOR <br />MAINTAIN 1/8" GAP <br />MEMBERS <br />BETWEEN SHEATHING <br />CONCRETE <br />AND TOP OF BLOCK <br />BLOCK <br />WALL <br />EXPANSION JOINT (EJ) AT FRAME & MASONRY <br />SCALE: 1/2" = 1'-O" <br />PREFORMED CONTROL <br />JOINT <br />FLANGE OF CONTROL <br />JOINTS TO BE WIRED TIED <br />TO LATH @ 9" O.C. MAX. (VERT.) <br />NOTE: DO NOT FASTEN CONTROL <br />JOINT TO WALL EVEN IF STUD <br />EXISTS BEYOND EXCEPT STAPLES W/ 8" <br />LEG MAY BE USED TO TEMP. <br />SECURE CONTROL JOINT <br />DURING INSTALLATION <br />FASTENERS TO BE SPACED @ 7" <br />O.C. MAX. VERTICALLY <br />LATH SHALL NOT BE BE CONTINUOUS <br />THROUGH CONTROL JOINTS <br />BUT SHALL BE STOPPED AND TIED AT <br />EACH SIDE PER ASTM C1063 7.10.1.4 <br />TYPICAL STUDS <br />TYPE "M" CONTROL JOINT (CJ <br />"L" FLASHING <br />SCALE: N.T.S. <br />8" THICK, 3 COAT <br />CEMENT PLASTER <br />60 MIN. GRADE D <br />PAPER BACKED LATH <br />APPROVED METAL LATH FASTENED @ 7" (VERT.) <br />O.C. MAX. AT SUPPORTS <br />BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />WOOD SHEATHING <br />PROVIDE 2X4 BLOCKING <br />FLAT MAX. 6" TO 8" FROM <br />CONTROL JOINT WHEN CONTROL <br />JOINT FALLS ON STRUCTURAL STUD <br />2X4 BLOCKING <br />NOTE: <br />1. FASTENERS FOR LATH TO BE NAILS OR <br />STAPLES IN COMPLIANCE W/ ASTM C1063 <br />2. WIRE TIES TO BE NO. 18 - 0.0475" WIRE <br />3. BLOCKING SHOWN MAY BE IN ADDITION TO <br />WALL STUDS REQUIRED PER PLAN <br />iwwkwjW ■tRulltlt"Sfl <br />,0 MIN. GRADE D PAPER BACKED <br />ATH OVER BARRICADE PLUS WRB <br />DR APPROVED EQUAL) <br />" THICK, 3 COAT CEMENT PLASTER <br />IETAL LATH <br />AP WRB & TAPE OVER ROOF/WALL <br />'CREED <br />,X5 "L" TYPE CONTINUOUS GALV. <br />IETAL FLASHING (NAIL TO ROOF <br />)ECK, NOT WALL SHEATHING) <br />DaE AND WATER SHIELD <br />5" VERTICAL AND 15" DOWN ROOF <br />;AP SHINGLE - DO NOT NAIL, <br />ASTALL WITH ROOF CEMENT <br />IOOF CEMENT <br />>HINGLE ROOFING <br />WOOD SHEATHIr'^ <br />BARRICADE PLUS WF <br />(OR APPROVED EQUA <br />LAP SIDING (PER BUILDE <br />MIN. LAP (PER MANUF. SPEC <br />STARTER STRIP (PER MANUF. SPEC <br />MIN. CLEARANCE (PER MANUF. SPEC <br />5X5 "L" TYPE CONTINUOUS GAL <br />METAL FLASHING (NAIL TO ROOF DEC <br />NOT WALL SHEATHIN, <br />CAP SHINGLE - DO NOT NAIL, INSTAI <br />WITH ROOF CEMEr <br />ROOF CEMEr <br />SHINGLE ROOFIN <br />"L" FLASHING -SIDING <br />SCALE: N.T.S. <br />8" THICK, 3 COAT <br />CEMENT PLASTER <br />60 MIN. GRADE D PAPER BACKED LATH <br />BARRICADE PLUS WRB (OR APPROVED EQUAL) <br />WRAP LAYERS OF BUILDING <br />WRAP OVER NAILING FLANGE, STOP <br />WRB APPROX. 1-1/2" ABOVE SHINGLES <br />ROOF/WALL SCREED <br />5X5 WALL FLASHING <br />KICK -OUT FLASHING (SEE DTL. BELOW) <br />FELT UNDERLAYMENT <br />SHINGLE ROOFING <br />— FASCIA WRAP <br />DRIP EDGE: OVERLAP 3", EXTEND <br />BELOW SHEATHING, MECH. FASTEN <br />4" O.C. MAX. <br />KICKOUT DETAIL <br />SCALE: N.T.S <br />z <br />Lo <br />13.. <br />BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />WOOD SHEATHING <br />WOOD CONSTRUCTION <br />60 MIN. GRADE D <br />PAPER BACKED LATH <br />METAL LATH <br />8" MID -WALL WEEP <br />SCREED <br />6" SELF-ADHESIVE <br />FLASHING <br />8" THICK, 3 COAT <br />CEMENT PLASTER <br />HORIZONTAL WEEP SCREED <br />SCALE: N.T.S. <br />STEP 1 STEP 2 <br />Q <br />FOLD <br />FOLD @ <br />FOLD INWARD @ PT. A <br />STEP 3 <br />: 0 <br />Q <br />FOLD @ 770 <br />FOLD INWARD @ PT. A <br />CREASE @ PT. B <br />CREASE @ PT. C <br />:J <br />FOLD INWARD @ PT. A <br />CREASE @ PT. B <br />STEP 4 <br />0 <br />WATERTIGHT SEAL. <br />FOLD. DO NOT CUT. <br />© © <br />BOTTOM FLANGE <br />JUN 0 8 2020 <br />FOLD INWARD @ PT. A <br />CREASE @ PT. BG. <br />® <br />CREASE @ PT. C <br />�,�����/®s <br />FOLD PT. C OVER PT. B TILL <br />�` �;-�'v� N <br />PT. C TOUCHES BOTTOM FLANGE No 'e <br />° ..s <br />gr z <br />r A OF <br />s ' s <br />RION. ��'�Z <br />fo>;iSPID�1i�! <br />Ir <br />W <br />�.=IY <br />O O F- <br />>oCQO <br />LU p F- <br />U) W w <br />QpujI-- <br />Jv J � .. /w <br />D CrI..L <br />///V��^, <br />W O O O cn <br />W'JQ�z <br />Q_L <br />T_ <br />U) 0 <br />�1zu-U) <br />� P < <br />' ^+ o <br />r` <br />ON <br />�v Q O <br />FZ <br />H <br />0 <br />0 <br />® <br />U) <br />4 <br />j <br />14 <br />1.1 <br />rr <br />V <br />O <br />A <br />LLO <br />O <br />O <br />U) <br />Aftj <br />0 <br />tn <br />W <br />U� <br />zul <br />Od <br />�o <br />� <br />z <br />I aaaaa <br />COMMUNITY: <br />LINKS AT CALUSA <br />SPRINGS <br />PLAN # 6102 <br />RELEASED: 5/ 14/20 <br />SHEET <br />WP I <br />