Laserfiche WebLink
INSULATION PER — <br />COMMUNITY SPEC. <br />SEE ENERGY CALCS. <br />1/2" (MIN.) CLG. BD. <br />WINDOW PER PLAN <br />PROVIDE BATT INSUL. — <br />PER ENERGY CALCS. <br />PRE-ENGINEERED <br />FLOOR TRUSSES <br />w/ 3/4" SUBFLOOR <br />SCREWED AND GLUED - <br />REFER TO STRUCTURAL <br />DRAWINGS FOR SIZE AND <br />ORIENTATION <br />1/2" (MIN.) CLG. BD. <br />DRAFTSTOPPING AS <br />PER R302.12 WHEN <br />CONCEALED SPACE <br />EXCEEDS 1,000SF <br />ix6 PT DRAPE BLKG <br />ABOVE WINDOWS <br />WINDOW PER PLAN <br />SOLID SURFACE <br />CAULKED @ WINDOW <br />1/2" GYP. BD. OVER RADIANT <br />BARRIER INSULATION (R-4.1) <br />ATTACHED TO 1x2 PT. <br />FURRING @ 24" O.C. <br />BASE BOARD <br />ROOF SHINGLES OVER <br />15# ROOFING FELT <br />OR <br />CONCRETE TILE W/ SELF ADHERED <br />MEMBRANE UNDERLAYMENT <br />60 MIL. OR EQUAL <br />PRE-ENGINEERED ROOF <br />TRUSSES AT TYP. 24" O.C. <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />OILTOPOFWALL <br />'A(REFER TO ELEV.) <br />SEE 2x6 ALUM WRAPPED FASCIA <br />ELEV. BD. w/ALUM DRIP EDGE. <br />SOFFIT PER SPECS <br />HEADER PER STRUCTURALS <br />—EXTERIOR FRAMED WALL <br />THICKNESS PER PLAN <br />7/8 STUCCO OVER LATH <br />W/ 60 MIN. GRADE D PAPER BACKED <br />LATH OVER BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />WALL SHEATHING PER <br />STRUCTURAL PLANS <br />h TOP OF FLOOR <br />(REFER TO ELEV.) <br />MID -WALL WEEP <br />SCREED/EXPANSION JOINT <br />h TOP OF CMU <br />(REFER TO ELEV.) <br />mk TOP OF WINDOW <br />(REFER TO ELEV.) <br />SEE STRUCTURAL <br />DRAWINGS <br />PRECAST WIN. SILL <br />8" CMU BLOCK <br />w/ CEMENTITIOUS <br />FINISH <br />SLOPE GRADE AWAY <br />FROM HOUSE <br />0'-01, <br />FIN. FL. <br />FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />TYP. 2-STORY WALL SECTION <br />ATTIC OR <br />SECOND FLOOR <br />LIVING SPACE <br />REFER TO PLANS <br />GYPSUM — <br />PROVIDE 2X4 <br />GYPSUM <br />BOARD <br />FRAMED <br />BOARD z <br />ENCLOSURE FOR <br />3 1/2" a <br />1„ GYPSUM <br />ELECTRICAL <br />w <br />z <br />BOARD <br />PANEL, FINISH W/ <br />GARAGE n- <br />2" GYPSUM <br />BOARD <br />NICHE FOR <br />ELECTRIC METER <br />;%` <br />ELECTRICA <br />LOCATION - SEE <br />% <br />PANEL & <br />PLANS. VERIFY <br />%' <br />WIRING <br />INSTALLATION IN <br />N <br />FIELD <br />�; <br />ELECTRICAL <br />STUCCO <br />A. <br />PANEL <br />ELECTRICP <br />PANEL <br />FINISH <br />EXTERIOR <br />EXTERIOR- <br />CMU BLOCK <br />CMU BLOCI <br />WALL <br />WALL <br />NOTE: ELECTRICAL <br />PANEL IS TO BE CONCRETE CONCRETE <br />INSTALLED ACCORDING CURB REFER CURB REF <br />TO ALL APPLICABLE TO PLANS <br />LOCAL, STATE AND TO PLANS <br />NATIONAL CODES. <br />VERIFY PANEL CONCRETE <br />DIMENSIONS PRIOR TO Y }Js SLAB ON <br />�tTCONSTRUCTION. GRAD��x <br />E GRADE AT <br />GARAGE <br />SEE <br />SOFFIT AT RAKE (BEYOND) <br />REFER TO PLANS <br />- FINISH PER PLAN <br />:- -=--: <br />7/8 STUCCO OVER LATH <br />W/ 60 MIN. GRADE D PAPER BACKED <br />LATH OVER BARRICADE PLUS WRB <br />(OR APPROVED EQUAL) <br />BENT METAL FLASHING <br />REFER TO "L" FLASHING DETAIL <br />2X LEDGER BOARD <br />TOP OF C.M.U. <br />(REFER TO ELEV.) <br />INSULATION AS <br />2X ALUM WRAPPED FASCIA <br />PER SPECS. <br />BD. w/ALUM DRIP EDGE <br />1/2" (MIN.) CLG. BD. <br />SOFFIT AS PER SPECS. <br />PRE-ENGINEERED <br />HURRICANE STRAP EACH END OF <br />GABLE END ROOF <br />TRUSS - REFER TO STRUCTURAL <br />TRUSS - REFER TO <br />STRUCTURALS <br />MASONRY LINTEL, SEE <br />STRUCTURALS <br />TYP. PENT <br />ROOF <br />DETAIL <br />SCALE: 1/2" = 1'-O" 1-STORY - MASONRY WALL <br />ROOF SHINGLES OVER <br />15# ROOFING FELT <br />OR <br />CONCRETE TILE W/ SELF ADHERED <br />MEMBRANE UNDERLAYMENT <br />60 MIL. OR EQUAL <br />12 <br />SEE ROOF <br />PRE-ENGINEERED ROOF <br />PLAN <br />TRUSSES AT TYP. 24" O.C. <br />' <br />BOTTOM CHORD VARIES. REFER <br />TO TRUSS MFGR. DRAWINGS. <br />\ <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />Z <br />TOP OF C.M.U. <br />I <br />(REFER TO ELEV) <br />SEE 2x6 ALUM WRAPPED FASCIA <br />ELEV. BD. w/ALUM DRIP EDGE. <br />1/2" (MIN.) ------ <br />SOFFIT PER SPECS <br />CLG. BD. <br />($" TYPE'X' GYP. BD. <br />SEE STRUCTURAL <br />TO BE PROVIDED <br />PLAN <br />WHEN LIVING SPACE <br />IS ABOVE GARAGE) <br />8" CMU BLOCK <br />W/ CEMENTITIOUS <br />FINISH (BEYOND) <br />GARAGE SLAB, ___\ <br />SEE STRUCTURAL <br />PLANS <br />ROOF SHINGLES OVER <br />15# ROOFING FELT <br />OR <br />CONCRETE TILE W/ SELF ADHERED <br />MEMBRANE UNDERLAYMENT <br />12 <br />60 MIL. OR EQUAL <br />SEE ROOF <br />PRE-ENGINEERED ROOF <br />PLAN <br />\ <br />TRUSSES AT TYP. 24" O.C. <br />' <br />BOTTOM CHORD VARIES. REFER <br />\ ,n <br />TO TRUSS MFGR. DRAWINGS. <br />\ <br />HURRICANE STRAP EACH END <br />OF TRUSS - REFER TO <br />STRUCTURAL. <br />OL TOP OF C.M.U. <br />(REFER TO ELEV.) <br />1/2" EXTERIOR SOFFIT <br />SEE 2x6 ALUM WRAPPED FASCIA <br />BD. W/ KNOCKDOWN <br />ELEV. BD. w/ALUM DRIP EDGE. <br />PLASTER FINISH <br />SOFFIT PER SPECS <br />SEE STRUCTURAL <br />PLANS <br />8" CMU BLOCK <br />W/ CEMENTITIOUS FINISH <br />EXPANSION JOINT SLOPE GRADE AWAY <br />DRIVEWAY PER COMMUNITY FROM HOUSE <br />4" SPECS <br />O, 0'-0" 0'-01, <br />SLOPE FIN. FL. i SLOPE FIN. FL. <br />®° <br />Im <br />WALL SECTION <br />SCALE: 1/2" = 1'-O" <br />ER <br />ATTIC OR SECOND <br />FLOOR LIVING SPACE <br />REFER TO PLANS <br />T.O. M <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I <br />I <br />I <br />I I <br />L ----- J <br />z <br />Q <br />tL <br />� <br />w <br />EIE: <br />i <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I I:1E <br />I <br />i <br />I <br />I <br />I <br />i <br />I <br />I <br />I <br />I <br />I <br />- <br />N <br />ih <br />00 <br />i\l <br />— <br />N <br />io <br />L <br />L <br />----- <br />----- <br />< <br />% <br />FLOOR <br />ELECTRICAL PANEL NICHE AT CMU BLOCK WALL <br />SCALE: 1/2" = 1'-O" <br />—FOUNDATION I I <br />PER STRUCTURAL DRAWINGS FOUNDATION <br />PER STRUCTURAL DRAWINGS <br />GARAGE DOOR TYP. CMU COLUMN @) LANAI/PORCH <br />SCALE: 1/2" = 1'-O" <br />NOTE: THESE DETAILS DEPICT <br />ARCHITECTURAL SPECIFICATIONS AND <br />FINISHES ONLY. REFER TO STRUCTURAL <br />DRAWINGS FOR STRUCTURAL INFORMATION <br />JUN 0 8 2020 <br />tY <br />w <br />�0>i­— <br />>cr<0 <br />cnUww <br />tY cr_ cr <br />Y 0 !— Z <br />06u-00C/) <br />Z z z F- <br />Z_ <br />w J Q J <br />w0-=I2cr <br />_3cnp00 <br />=ZLLcf) <br />< <br />g <br />N <br />Q <br />r� <br />V <br />I...l <br />Vl <br />�s <br />I�1 <br />® <br />wa <br />J �I...r <br />x <br />U U <br />m <br />W.." W <br />MMM14 <br />w <br />rra <br />cl <br />I <br />I <br />i <br />I <br />I <br />Z <br />O_ <br />I <br />I <br />I <br />I <br />i <br />I <br />I <br />U <br />I <br />w <br />C3 <br />I <br />I <br />I <br />I <br />U <br />O <br />I <br />I <br />I <br />N <br />p <br />w� <br />f <br />aEaaa <br />i <br />c <br />f <br />c <br />F <br />c <br />c <br />is <br />i <br />c <br />L <br />c <br />COMMUNITY: <br />LINKS AT CALUSA <br />SPRINGS E <br />PLAN # 6102 L <br />RELEASED: 5/14/20 i <br />SHEET <br />A502 :1 <br />z <br />A <br />:n <br />z <br />O <br />J <br />z <br />A <br />