36355 Well Hill Way
Zephyrhills
>
Building Department
>
Building Plans
>
36355 Well Hill Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:52:04 AM
Creation date
2/19/2025 9:59:59 AM
Metadata
Fields
Template:
Building Plans
Street #
36355
Location
Well Hill Way
Contractor
Lennar
Building Plans - Permit #
6699
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXTERIOR PLASTER <br />ON FRAME <br />12 <br />5� <br />25 SH 25 SH <br />FIBERGLASS SHINGLE INSTALLED AS PER <br />MANUFACTURER SPECIFICATIONS <br />_ T.O.P. <br />HDR. HGT. <br />------I-- ------- i------------------------I--- 2ND FIN. FLR. <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON CMU <br />CJ / WEEP <br />35 SH <br />6068 SGD <br />_ T.O. <br />HDR <br />FIN. <br />REAR ELEVATION — ELEV—B <br />SCALE: 1 /4" = V-0" <br />00 <br />C1 M CMI AOQ QLI I N If�I C IA IOTAI 1 Cr'1 AQ r)Cr) <br />RIGHT ELEVATION — ELEV—B <br />SCALE: 1 /4" = V-0" <br />ERIOR <br />3TER ON <br />NE <br />-URED <br />ENTITIOUS <br />tH ON CMU <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />I Cxter►or uovering I <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath, <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having a 7/16" head, or 1-1/2" long, <br />16 gage staples, spaced in accordance with ASTM C1063 or <br />C1787, or as otherwise approved. (Refer to sheet SN1 for the <br />engineered method for Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4"-1" crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with 1" dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702,1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br /><*a <br />c <br />dUJ <br />9 W <br />0 <br />LJ <br />CO V <br />N <br />O L <br />Q CV <br />3 =' W <br />CU <br />S <br />d C� <br />En <br />_E <br />a v <br />t t t t tttartj�f� <br />��\>>��f;�►I <br />` <br />NSA. <br />,� • <br />:\G� •� <br />r�L <br />FL <br />=y. <br />OpESS60r`� <br />�= <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal, <br />,Wp <br />OO C`i GEj <br />Q <br />/ <br />V <br />CV o <br />N O m to � <br />rgg <br />05a) �0 <br />� <br />,A �i <br />d Q <br />CIS r' <br />N O ik LL <br />N M V J <br />C J LL <br />J UL LL W <br />w a <br />g Z <br />— E: o <br />N p <br />Y 0 <br />S0 <br />W <br />U) m <br />1 Z,rn� <br />J <br />M Z Q <br />N J <br />V <br />0 <br />O U U <br />s W <br />V M <br />N M <br />o g <br />z <br />Q � a <br />J <br />a. <br />U) <br />N <br />M <br />z <br />v <br />o <br />4.1 <br />f13Lij <br />� <br />M <br />0 <br />N <br />t/1 <br />,Le oQ) <br />N <br />-n <br />�a <br />U <br />_ J <br />LSd>w�� <br />W c0i <br />N <br />q <br />U o <br />Q N 0co <br />o <br />w <br />M <br />ZO , <br />ZZZ <br />Q <br />LL. <br />Z <br />Zo <br />>M <br />z® <br />o <br />E U <br />' <br />oa <br />F— r0 <br />CL <br />x o <br />00 <br />U <br />O E <br />o <br />¢ <br />'0 <br />p K <br />�Z <br />ZN <br />t <br />wo <br />o <br />.w <br />c <br />O <br />Go <br />O U <br />m <br />m0 <br />° o <br />Z <br />Zm' <br />v <br />a w <br />0 <br />0� <br />Z Z <br />Q o <br />W <br />co <br />m <br />50 <br />wa <br />�O <br />o <br />`r <br />ZIa <br />a <br />° 3 <br />0 0 <br />M <br />m <br />or <br />m <br />m <br />0 <br />CID (0 <br />C> <br />=) r <br />C4 <br />^ <br />>, <br />r <br />LO <br />LO O <br />L O <br />N <br />Q <br />M <br />T <br />E <br />co <br />0 <br />o <br />Z <br />Z <br />' <br />E O <br />a <br />E <br />U <br />Q <br />-� <br />JOB <br />NO: <br />23-06103 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />2.2 <br />