ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501,17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />h SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j WALL SWITCH <br />$3 THREE-WAY SWITCH <br />j4 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />© HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />I-o WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />nD ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />DB PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />TV TELEVISION (OPTIONAL) <br />TV 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />M ELECTRIC METER <br />FI__ ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />� J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />150AI200A INDOOR <br />PANEL CENTER <br />14 to lights 8 outlets <br />12 to appliances and GFI <br />10 to WH <br />B to Range <br />5 to HVAC <br />" Conduit <br />UNDERGROUND Disconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 17, 2%94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />1.5" VTR III 3" VTR <br />lil\ I\ <br />I <br />I I <br />I I <br />I <br />I <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RAN( <br />HOOD PER SPECS <br />1113" VTR <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />I 1 <br />I u SWITCH FOR <br />I O DISPOSAL <br />I <br />_J <br />ILL <br />X I GFIEl <br />N <br />[IFGFI 7" <br />-_- -L <br />� I <br />ITCHEN <br />CZit�iil, 5 - <br />'t' <br />�L'Y1L'7C'1LY <br />—C <br />SPEC 3 & 4 KITCHEN <br />DEDICATED// <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />NOOK <br />_.� — — — — — — — — — — — — — — — — — — — — — — <br />LANAI <br />G � <br />ROUGH -IN FOR , <br />OPT. CLG. FAN/' <br />LIGHT PRE -WIRE <br />SWITCH FOR 1 <br />DISPOSAL FAMILY <br />PENDANT ROUGH -IN FOR I <br />AS PER OPT. CLG. FAN/ <br />SPECS LIGHT PRE -WIRE <br />G � / <br />L <br />GFI 1 <br />ITCHEN\ / <br />—RI'EFF <br />LAU <br />it GFI <br />O \ I GFI `I <br />O Iv / <br />CH <br />DINING <br />PENDANT AS <br />PER SPECS <br />t <br />C.M. <br />I I <br />PWDR <br />I'1'1' I' I`T- I' 1' 1' 1' 1' 1' 1' I' I' I' I i I'I <br />GFI @ 44" r — GFI @ 44" <br />A.F.F. A.F.F. <br />w w W.H. <br />�o /wz� <br />�0m , \ <br />LM U F- <br />I 1 <br />>O� <br />----------\-------------- I-------- <br />ZW <br />GARAGE <br />/ <br />Oz <br />Q <br />ell 0_ <br />I \ <br />O i \ <br />ENTRY <br />_ WP <br />FI TO <br />o v � � IGARAGE / GFI------ I BEALII�GNED <br />>_ rr L-- ;'—��IGHT AS o VERTICALLY <br />LL <br />Fr w PER SPECS / I <br />>Lu <br />GARAGE I <br />---------------0.00R---------------, <br />GFI I <br />I IRRIGATION I <br />GFI @ 44" / <br />A.F.F. <br />I I / <br />I I <br />I I <br />I I <br />I I / <br />------------------------------ <br />(5\ /6— <br />COACH LIGHTS /COACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS / PER SPECS <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I <br />I I I <br />I I I <br />I I I <br />I I I <br />IL----------- <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L- — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — J <br />SECOND FLOOR ELECTRICAL PLAN <br />FIRST FLOOR ELECTRICAL PLAN — ELEV—A <br />ELEV—A <br />Lam% <br />C) <br />® <br />M <br />61 <br />d to <br />v= = sa <br />G <br />RC O <br />� v <br />M <br />O <br />M <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />v E N <br />O <br />t o <br />N !T ik O <br />W C u0i ik <br />00 ik Lt. <br />N <br />tlJ <br />to LL <br />a)��� w <br />C) a a <br />a <br />oNi w <br />6- 4 c� <br />� <br />ZJ <br />_m <br />13 <br />Zo'0 <br />sj.o O <br />_ <br />m Q <br />co 1z <br />Gw <br />CC)LLW <br />U <br />Nt.)ZH <br />O U ❑❑❑ <br />2 N (7 <br />O CD <br />zco <br />� o <br />0. <br />N <br />M <br />V) <br />Q) <br />a <br />,U <br />O <br />LUN <br />o <br />C) c <br />— 8. <br />L <br />U o <br />Y <br />O <br />o <br />®® <br />N m <br />o <br />M <br />J <br />w <br />z <br />Z <br />g <br />Q o <br />u <br />o <br />o� <br />j <br />Z© <br />oa <br />ZC <br />Co <br />ot <br />00 <br />oE <br />a <br />ao <br />(/D <br />m <br />3a <br />Q <br />p U <br />�m <br />2azi <br />0 <br />Z <br />aw <br />o� <br />zz <br />go <br />W <br />[n <br />CID <br />< 0 <br />a <br />W <br />- <br />a z <br />LD <br />�� <br />0 <br />.5o <br />>M <br />O <br />�• <br />rn <br />� <br />V <br />v <br />L <br />Cfl <br />co <br />r <br />: r <br />Cfl <br />�1 <br />07 <br />T <br />~ <br />In <br />Ln <br />O <br />a) <br />o <br />a) o <br />V) <br />0 N <br />r <br />M <br />T <br />CIO <br />LO <br />z <br />Z <br />E T­ <br />N <br />N <br />c <br />a <br />U <br />Q p <br />JOB <br />NO: <br />23-06116 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />11 IT rrI I I I11 11 1 1 1 IllIT 11 I <br />