Laserfiche WebLink
I I I � - I'l '' I I I I , IIII I J I - <br />FOLD UP WEATHER <br />RESISTIVE BARRIER & WEATHER RESISTIVE <br />TEMPORARILY SECURE BARRIER DOOR ROUGH OPENING WINDOW UNIT <br />WEATHER SLOPE <br />R S S TIVE 0.3 in: 12.0 in <br />E 'I <br />BARRIER WOOD FRAME CONSTR. <br />TAPE EXTERIOR SELF -ADHERED FLASHING 3/4"-1 " BEAD OF CONSTR. (0. 6 cm : 30.5 cm) <br />SHEATHING <br />3 BY LAPPING DOWN ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING <br />OVER RIM JOIST AND U THRESHOLD OF DOOR AND RETURN <br />WALL BY 6 IN. UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING EXTERIOR <br />C2 CEMT. FIN. <br />WEATHER BUILDING PAPER <br />VVInL_ <br />SELF -ADHERED FLASHING <br />RESISITIVE <br />BARRIER <br />SEAL TOPS OF JOISTS WIRE LATH <br />UNDER DECKING SUBFLOOR <br />(SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />777 <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weather resistive RIM JOIST <br />THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing <br />installation <br />MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under L V, <br />AND WATERPROOFING METHODS TO weather resistive barrier <br />BE USED. 3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS SELF -ADHERED FLASHING SELF -ADHERED FLASHING <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER EXTERIOR DOOR WITH DECK - SECTION A SUN CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />EXTERIOR SHEATHING FLASH�NG,JAMB & HEAD MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />EXTERIOR SHEATHING 3/4"-1" BEAD OF CONSTR. INSTALL SELF -ADHERED NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />ADHESIVE TO BE APPLIED UNDER THROUGH SELF -ADHERED <br />THRESHOLD OF DOOR AND RETURN FLASH NG SEE FLASHING SELF -ADHERED FLASHING <br />UP JAMB 6". USE LIQUID NAIL BRAND FLANGED WINDOW <br />OR EQUAL WEATHER PROOF CAULKING (SEE DETAIL WP01) <br />REFER TO TECHNICAL SCORED <br />LETTER ON CHEMICAL RELEASE PAPER <br />COMPATIBILITY <br />SELF -ADHERED FLASHING - SELF -ADHERED FLASHING, (BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />EXTEND A MINIMUM 6" ADHESIVE AS SHOWN) <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />C�4 <br />CID <br />1 E <br />0 <br />1 1 <br />F! <br />En L <br />SECTION -A (SEE DETAIL WP02) <br />*J L- SELF -ADHERED FLASHING <br />SELF -ADHERED FLASHING <br />o NAILING FLANGE 1 <br />2 SEAL TOPS OF JOISTS <br />DO NOT FLASH OVER UNDER DECKING <br />BOTTOM NAILING 8 (SEE DETAIL WP07) <br />FLANGE I <br />NOT USED <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />FLMQF1II1%J I ­ -- <br />SELF -ADHERED FLASHING <br />DECK JOIST I <br />E <br />AM <br />Q <br />SELF-ADHEF <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />PLASTER STOP <br />CONTINUOUS BACKER <br />ROD & SEALANT <br />Me <br />14 <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. <br />DO NOT SEAL. <br />DRIP SCREED PLASTIC <br />ACCESSORY <br />SOFFIT/CANTILEVER <br />IN <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />-7 Ground 7 <br />FOUNDATION WEEP SCREED <br />LEGEND <br />SELF ADHERED FLASHING (SAF) <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BREAK WEATHER RESISTANT BARRIER <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING, 'OSB% PLYWOOD, DENSGLASS <br />121 <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />----STRUCTURAL FRAMING <br />--- STRUCTURAL SHEATHING <br />---STRIP OF SAF <br />)--DRAINAGE PLANE WRB <br />-r- BOND BREAK WRB <br />ILI ISF LATH <br />ER STOP A <br />NUOUS BACKER ROD <br />LANT <br />4TITIOUS FINISH <br />FLASHING REQUIREMENTS. <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.1 5 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barder. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface ot he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more ofthe <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 GaIv. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS. <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as G in each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1 . Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (16" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />WOR <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Oak <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC 1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />16Z <br />60M <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC 1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />.Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />/7 <br />A <br />CO <br />CD <br />CL_ <br />13 <br />V) (D <br />C <br />Q) C_/3 <br />+_J LU <br />0 L_U <br />4-h 0,_ <br />E <br />ZD <br />V) <br />0 <br />23 M <br />.2 C5 <br />M r- <br />04 <br />Lii <br />E <br />8 <br />4) co <br />0) M <br />r_ M M <br />-0 C') <br />a cli <br />C) <br />0 0 C=I <br />U_ 00 <br />C6 ?� <br />CO.",- <br />U) <br />a) 0 <br />A I <br />R D. <br />6 <br />AU .2, Z- <br />U) <br />ED <br />LU -E <br />Z 0 &;5; < <br />4 <br />C, r, OM <br />U) M E CP <br />Z <br />LL U1 <br />C-3 <br />WWW FDSENG.COM U Li <br />O'�, <br />00 <br />cli <br />To the best of the Engineers knowiedge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and sea]. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />0 Z <br />i0 <br />M <br />Z 0. <br />U 0 <br />zd� <br />�Ezl <br />U) <br />0 uJ <br />Lu <br />< <br />uJ <br />10 (n <br />> <br />LJJ <br />M <br />Z Z <br />M Z <br />Ce <br />Z <br />C: <br />LL. <br />0 <br />L4 3: <br />Z <br />0 <br />0 <br />Cr <br />U <br />cl- <br />LLJ <br />LL, 9 <br />0 <br />Lr) <br />8: <br />Lh <br />< <br />0 <br />W. -� <br />Z <br />< <br />Z <br />Z <br />L:Ij <br />2 �i <br /><ujt8 <br />< <br />< <br />Z <br />U <br />W uJ 8 <br />c) <br />Z <br />tu <br />C113 <br />0 <br />V <br />Z <br />LU <br />T <br />_J <br />Z <br />UJ <br />X <br />rn <br />CL <br />U) <br />F) <br />SCALE AS NOTED <br />DATE 5/7/2019 <br />TECH: FFLORES <br />VERSION NO 10 <br />SHEET NO. <br />W P <br />