My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39922 Dawson Chase Dr
Zephyrhills
>
Building Department
>
Building Plans
>
39922 Dawson Chase Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:39:53 PM
Creation date
2/19/2025 10:07:51 AM
Metadata
Fields
Template:
Building Plans
Street #
39922
Location
Dawson Chase Dr
Contractor
Lennar Homes
Building Plans - Permit #
21907
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
^' ^ 10 WEATHER <br />JE BARRIER & <br />IARILY SECURE <br />WEATHER <br />RESISITIVE <br />BARRIER <br />TAPE <br />(ASSEMBLED WINDOW ) <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weat <br />THESE DETAILS ARE GENERIC AND barrier above header to allow for flashing <br />installation <br />MEANT TO SHOW GENERAL FLASHING 2. Self -adhered flashing plus head flashing under <br />AND WATERPROOFING METHODS TO weather resistive barrier <br />BE USED. 3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING - <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />NAILING FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHING <br />SHEATHING BY LAPPING DOWN <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOK <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />8 Z <br />SELF -ADHERED FLASHING <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />- 3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHERPROOF CAULKING <br />SECTION -A (SEE DETAIL <br />SELF -ADHERED FLASHING <br />SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />0 <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />SELF -ADHERED FLASHING <br />PATCH <br />8 2 <br />WINDOW UNIT <br />SLOPE <br />0.3 in : 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />WIRE LATH <br />O <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER , <br />MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />THROUGH SELF -ADHERED <br />FLASHING SELF -ADHERED FLASHING <br />SCORED <br />RELEASE PAPER <br />�v (BEFORE FOLDING, SCORE <br />RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) <br />V <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />-►(Ground <br />Lo <br />IO <br />�O <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />FLASHING REQUIREMENTS <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1 /2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked asO# in each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />E v <br />° <br />AM <br />1 SELF -ADHERED FLASHING ° Foundation Wall <br />SELF -ADHERED FLASHING ° a <br />3" MIN <br />4 , <br />ru•�onuv�a rL_r�an(rv�a O i' � � <br />5 <br />, <br />SELF -ADHERED FLASHING SELF -ADHERED FLASHING ' <br />DECK JOIST I OUTSIDE CORNER i FOUNDATION WEEP SCREED <br />PLASTER STOP - <br />CONTINUOUS BACKER - <br />ROD & SEALANT <br />A <br />NOT USED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />_ WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. <br />DO NOT SEAL. <br />DRIP SCREED PLASTIC <br />ACCESSORY <br />SOFFIT/CANTILEVER <br />LEGEND <br />SELF ADHERED FLASHING (SAF) o <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH ^\ <br />PLASTER ACCESSORY <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS QSS�SS <br />STRUCTURAL FRAMING <br />STRUCTURAL SHEATHING <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />Cement Plaster <br />in accordance <br />With ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />-Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />U� <br />O <br />0 <br />Z N S <br />m <br />o <br />Z <br />v <br />Q <br />J M <br />d N <br />_ M <br />z ° <br />lL <br />GX <br />w o <br />� Q <br />.O 'm <br />w <br />cN ry o <br />�N o <br />U 00 <br />d <br />LL, ® rn <br />F- m E <br />0ZE; 8 <br />xlv <br />O W <br />a 0 <br />O <br />sm <br />N N <br />Z U) o t <br />d <br />w <br />Z III gM_Zo <br />U) n o a w <br />N <br />LU a > rn� <br />W <br />0 <br />a c n <br />Z O O <br />�'oa3 g <br />A <br />��o <br />U) :2E <br />LL rn O c4 A <br />W a <br />O rj U <br />O <br />N <br />M <br />O <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />o <br />Cam-) <br />w <br />Z <br />Cl) <br />zo <br />lL <br />E <br />zo <br />�Z <br />Zm <br />Q� <br />Iz <br />E=- 0 <br />CIO <br />Z <br />OU <br />z <br />W,1 <br />o4 <br />0U <br />(6K <br />_ <br />O<Qz <br />U <br />¢ <br />U <br />p <br />Q 4 <br />ZC:) <br />z <br />� <br />� <br />(C <br />IamoW <br />U Y <br />U <br />N <br />0, <br />Z <br />Z <br />m <br />Q W <br />2W <br />W <br />3 <br />0¢ <br />go <br />sZ <br />U � <br />w � <br />a� <br />a <br />�F <br />�r <br />O <br />oz <br />¢ <br />=3 <br />0E- <br />� o <br />Cno <br />CID <br />C' <br />w <br />zla <br />i; 3 <br />0 <br />O <br />> d' <br />L <br />> <br />CU <br />� <br />O <br />(1) <br />O <br />C0 ,C <br />v <br />m C <br />h <br />_ <br />W <br />O <br />TTr <br />0) <br />'^ <br />V, <br />T <br />T <br />T <br />tea/ � N <br />O co <br />ui <br />N <br />3 C:) v; I <br />o <br />? <br />Z <br />e O <br />cc <br />a <br />U _J� Q p <br />41 <br />JOB <br />NO : 19-5893 <br />SCALE : AS NOTED <br />SHEET NO. <br />W P <br />
The URL can be used to link to this page
Your browser does not support the video tag.