Laserfiche WebLink
$ <br />1 V-8" 40 6'-9" <br />SH 25 <br />HD AT 6'-8" <br />EGRESS <br />5068 SGD <br />C900 <br />H.B. \ U 2868 <br />ti <br />� J <br />\ Q <br />\ N <br />OWNER'S SUITE <br />\ °-�° 15'-8" X 11'-11" <br />\ 0 8'-0" CLG <br />\ / N <br />60 <br />ti <br />12'-7 5/8" \ 6'-3" 3'-9 1/2" 6'-0 5/8" <br />GREAT ROOM <br />14'-4" X 12'-6" \ <br />VAULTED AIV A. <br />2868 <br />2.5/12 VAULT. Z" 2868 <br />CLG \ <br />12" DP ,ilO. BATH CIF <br />(5) SH M 8'-0" CLG <br />W.LC TP N <br />8'-0" CLG N <br />M <br />cn I 36" x 60" B T <br />o r .61 SHOWER PAN <br />Ac— <br />rn I o DRAIN <br />0O M � DINING . I v SHW HD <br />M z 10'-0" X 12'-6" 1 `" cm & VALVE <br />Q VAULTED <br />❑ 00 N <br />_ L---- cV cc r <br />R&SLL <br />o <br />N M 0- <br />0000 CD <br />❑ U) I <br />N N I T-3 1/2" 4'-2 5/8" <br />CPT. <br />TILE M "> <br />iu C1 Co <br />L " ry ( BEDROOM #3 <br />KITCHEN �� z I N 11'-1" X 10'-1" <br />12' 6 13 6 u J I _ 8 -0 CLG <br />VAULTED q C N cn - ❑ <br />z w0 C N <br />u oo w ZO O r �� <br />2.5/1 2 C C° U ti �O N io w <br />VAULT. --- r Q CK <br />CLG Y co ❑ w <br />-- DW 2'-3 1/2" co 1 V-6 1/8" _ <br />9 Fe7 <br />4n =_--_ ---- 2668 <br />CD 4,-6„ 2,-0„ <br />N <br />4'-5 1 /4" 7'-11 1/2 ao 3'-9 3/8" -3 1 /2" 2668 _ 10'-3 1 /8" op U) <br />C? 00 `� ip <br />8'CY)-0" CLG Q W <br />REF ��6� o w <br />r 4 <br />N N BEDROOM #2 <br />5 SH 9'-10" X 11'-1" <br />2" DP (5 a BATH co8'-0" CLG <br />H TB TP <br />#2 I <br />20 2'-9 1/2" 3'-2 3/4" 8'-0" CLG 1 <br />M S� 06 (O b0 <br />2.5/12 00 <br />_ r---L—� <br />VAULT. [::D INSULATED <br />CLG oWALL J <br />20 MIN. ---- <br />AHU PLATFORM M RATED <br />DOOR W/ <br />LAUNDY WEATHER 22-1/2" x 54":7 PROTECTIVE <br />FOYER 8'-0" CI_G STRIP ATTIC ACCESS BOLLARD <br />4'-4" X 12'-8" `'cP6 ��oq' mmmi K <br />VAULTED LO 7SHELVES IN S3 <br />LAUNDRY AT <br />60" A.F.F. N <br />DRYER <br />1 o VENT <br />o I ' D W HANSEN <br />o M ° <br />I 3-1/2° BOX <br />1'-03'_8, 4"PADDED TWO CAR GARAGE <br />o — — — FRAME WALL 8'-0" CLG <br />12x12 CMU PORCH SH 1/2 33 <br />COLUMN VAULTED CLG HD AT 6'-8" _ _ _ <br />LINE OF GARAGE W <br />-0' 3'-8" 2'-0" 4'-0" I OPEN POSITION 1 <br />I <br />4'-8" 6'-0" I <br />I <br />I <br />i <br />I <br />16070 H.B. <br />1'-8" <br />10'-8" <br />man <br />FLOOR PLAN ELEVA <br />1 /4" = 1'-011 <br />16'-0" <br />19'-4" <br />V-8" <br />GENERAL NOTES: <br />ALL WINDOWS TO HAVE FLUSH SILLS. PITCH TOP SILL <br />FIN AWAY FROM WINDOW FRAME. <br />VERIFY ALL WINDOW AND DOOR ROUGH OPENING SIZES <br />WITH THE MANUFACTURER'S SPECIFICATIONS. <br />INSTALL RND DRYWALL BEADS AT HORIZ & VERT <br />CORNERS, EXCEPT AT EXT WALL OPENINGS OR AS <br />NOTED. <br />USE SQUARE CORNER BEAD AT DRYWALL NICHES & <br />REC CLG DETAILS; REC CLG SURFACES SHALL HAVE <br />SMOOTH FINISH. <br />LOCATE ALL PLUMBING & EXHAUST STACKS BEYOND <br />THE FRONT ELEV ROOF RIDGES, IF ALLOWABLE PER <br />CODE. <br />THE GARAGE IS TO BE SEPARATED FROM ADJACENT <br />LIVING AREA AND ATTIC SPACE BY 1/2" GYPSUM BOARD <br />AND HABITABLE ROOMS ABOVE BY NOT LESS THAN 5/8" <br />THK. TYPE "X" GYPSUM BOARD (OR EQUIVALENT) <br />APPLIED TO THE GARAGE SIDE. <br />TOWEL BAR - (T.B.)* = 42" A.F.F. OR U.N.O. <br />TOWEL BAR ABV TUB DECK* = 36" ABV. TUB DECK <br />TOILET PAPER DISP. - (T.P.)* = 20" A.F.F. <br />ROD AND SHELF (SGL)- (R/S) = 60" A.F.F. <br />ROD AND SHELF (DBL)- (R/S) = 40" & 80" A.F.F. <br />CORNER SHELF = 56" A.F.F. <br />MEDICINE CABINET - (M.C.) = 75" TO TOP OF CABINET A.F.F. <br />*PROVIDE 2X BLOCKING IN WALL AT ALL LOCATIONS FOR <br />T.B. AND T.P. <br />WALL LEGEND: <br />ALL EXTERIOR WALLS TO BE CONSIDERED SHEAR <br />RESISTANT COMPONENTS. <br />8" CMU W/ 1X3 PT FURRING STRIP <br />3/4" INSUL BOARD 1/2" GYP <br />8" CMU <br />NON -BEARING 2X4 STUD W/ 1/2" GYP. <br />LINO <br />BEARING WALL 2X4 16" O.C. W/ 1/2" <br />GYP. UNO <br />p = FILLED CELL W/(1) #5 VERTICAL <br />= FILLED CELL W/(1) #5 TURNED 2'-0" INTO SLAB <br />= FILLED CELL W/(2) #5 VERTICAL <br />C = FILL CELL TO ONE COURSE ABV PIPE (NO REBAR) <br />SQUARE FOOTAGE: ELEV A <br />AREA <br />PROPOSED <br />FIRST FLOOR LIVING <br />1448 <br />TOTAL LIVING SQ FT 1448 <br />ENTRY <br />19 <br />GARAGE <br />387 <br />TOTAL SQ FT 1854 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2X4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2X6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION <br />R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />JUN 27 2023 <br />Virtual Review Assist, Inc. <br />for Plans Review comet anee with lthe 2020 FBC 7ti <br />by Debra Anne Klahr PX2300 <br />ALLOWABLE WIND SPEED DESIGN PRESSURE <br />(140 mph, enclosed, 3 sec. gust, 2.1/12 to 6.9.12 pitch, <br />Exposure C, Height=30 ft, Importance Factor=1.0, End <br />Zone= 4 ft) <br />As per Florida Building Code 7th edition (2020), <br />Residential Table R301.2 (4) (Wind Speed Conversions) <br />and ASCE 7-10 Methods <br />WALL <br />TRIBUTARY <br />AREA (ft)2 <br />INTERIOR <br />END <br />10 <br />39.4 <br />-42.1 <br />39.4 <br />-51.8 <br />20 <br />37.6 <br />-40.5 <br />37.6 <br />-48.6 <br />50 <br />35.2 <br />-37.3 <br />35.2 <br />-43.7 <br />100 <br />33.4 <br />-35.6 <br />33.4 <br />-40.5 <br />GARAGE D <br />30.0 <br />-33.9 <br />30.0 <br />-33.9 <br />o <br />zt <br />LO <br />tggt 3 <br />LSD <br />G:,++ Ai a�v1 <br />00 <br />w <br />O <br />❑ <br />w <br />0 <br />z <br />ncn <br />N <br />W L � U <br />❑ M ti <br />N C) <br />cn <br />} <br />V O m u a <br />A, i L p <br />U8 C:)CD0 <br />0 tL o O Q <br />.N <br />U w QC� <br />UJ <br />L 00 � � <br />� a 4 <br />w <br />LLJ <br />z <br />a 0 <br /><0XJzXsoZ��0�Q° <br />F- <br />zzOU)9UzOX00M <br />X <br />w wwOZ wWW0iQU5zO <br />W <br />tl <br />-< Iz <br />QOw �I-P �LIJ <br />oa <br />Q <br />OX O Z pQ �¢ <br />LL¢ o <br />if <br />O <br />O <br />Z W <br />® F— <br />O <br />CM O <br />L w lL <br />z <br />F— W M <br />00 <br />< <br />Z V <br />W <br />W <br />J o <br />r� <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />N <br />o00 <br />0 <br />LO <br />N <br />r <br />N <br />M <br />N <br />N <br />M <br />CD <br />O <br />N <br />I <br />r- <br />N <br />O <br />O <br />- <br />O <br />, <br />O <br />O <br />N <br />W <br />o <br />CD`o <br />0 <br />0 <br />l <br />LO <br />� <br />e- <br />N <br />M <br />4L6 <br />l <br />z <br />W VJ <br />¢z <br />w <br />Oz <br />"`_' <br />U <br />WCF) <br />o00 <br />O <br />U U Fn <br />LO <br />p <br />Qzj <br />g�❑ <br />Z <br />airy <br />O= <br />w=w <br />m�� <br />~moo <br />T-I <br />z 0 = <br />W <br /><0 <br />L- <br />p <br />zoo <br />� C:)Q <br />C) <br />i z" <br />Z <br />z <br />ZQ <br />F <br />poi <br />W <br />"I <br />z <br />¢ <br />z <br />w <br />W qr-1 <br />CD <br />o <br />N <br />LAST PLOT DATE <br />• <br />May 4, 2023 <br />z - <br />_I <br />FLOOR PLAN A <br />