Laserfiche WebLink
Lll_ III I 1' 1 <br />THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />WEATHER <br />`RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTIC <br />1. Cut, fold up & temporarily secure 1 <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />TEMPORARILY SECURE <br />WOOD FRAME CONSTR. <br />EXTERIOR <br />SELF -ADHERED FLASHIN <br />SHEATHING <br />BY LAPPING DOWN ---, <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />3/8" CEMENT <br />PLASTER <br />12 MIL DRYLOK CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />S <br />1) SEALANT AT <br />4) SEALANT JOINT WINDOW BUCK TO <br />OUTSIDE EDGE OF `' MASONRY <br />WINDOW BUCK e <br />2) SEALANT JOINT <br />5) SEALANT FROM INSIDE EDGE OF <br />WINDOW FRAME WINDOW BUCK <br />ACROSS WINDOW BUCK <br />AND EXTEND TO WINDOW FRAME <br />MASONRY ATTACHED <br />PER CODE <br />6) TOOLED SEALANT REQUIREMENTS <br />BEAD BRIDGING <br />CLADDING AND WINDOW <br />FRAME 3) SEALANT WINDOW FRAME TO <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL. <br />DO N01 <br />BOTTO <br />n enrr_r <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />"V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />1 L/1U1 II , ­v, ,, - <br />SCS 0602 WINDOW FIN INTERFACE WITH <br />I <br />SELF -ADHERED FLASHING <br />EXTRUDED SHOULDER <br />DECK JOIST <br />SELF -ADHERED FLASHING <br />2x FRAMEWALL--_ <br />PRODUCTS DETAILS <br />TILE FINISH---_ <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC <br />1/2" DUROCK-�_ <br />R703.2.1 AND FBCR 703.7.3 <br />Detail Instructions <br />Refer to the number marked as 0 in each detail that corresponds to the <br />numbered items in the list of Instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />8" CMU <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />4" OR 8" CMU <br />3. Self -adhered flashing can be substituted for building paper <br />(PER SEAT DEPTH) <br />4. Split the release paper using the ripcord (Split release on demand, <br />FILL WITH GROUT <br />P <br />embedded in the adhesive layer) - for ease of installation and to <br />7, <br />minimize scoring cuts <br />d <br />5. Remove all release paper per standard installation instructions and <br />° <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />SLOPED MUD BED <br />d <br />6. Fold as shown by arrows <br />e <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />VINYL SHOWER PAN <br />- <br />° d <br />8. Mechanically fasten as necessary <br />H <br />SLOPE <br />d <br />4 <br />G <br />WEATHER \ <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOISTS <br />UNDER DECKING <br />ED FLASHING I (SEE DETAIL WP07) <br />�o� <br />0 <br />4SHING <br />WEATHER RESISTIVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING `� <br />1 0 <br />2 SEAL TOPS OF JOISTS <br />UNDER DECKING <br />8 (SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />E <br />AM <br />SELF-ADHEF <br />V <br />1'4" PER PLAN <br />V-0" PER PLAN <br />SHOWER SEAT <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />WINDOW UNIT FLASHING REQUIREMENTS <br />�- DOOR ROUGH OPENING SLOPE <br />0.3 in : 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />(0.6 cm : 30.5 cm) include flashing as described in Section R703.4. A water -resistive barrier is described as a material behind an exterior wall covering that is <br />- 3 ADHESIVE <br />BEAD OF APPLIED <br />Intended to resist liquid water that has penetrated behind the exterior covering from further intruding Into the exterior wall assembly. An <br />ADHESIVE TO BE APPLIED UNDER - SELF -ADHERED FLASHING q p g g y• <br />THRESHOLD OF DOOR AND exterior wall covering is described as a material or assembly of materials applied on the exterior side of exterior walls for the purpose of <br />RETURN UP JAMB 6". USE LIQUID <br />NAIL BRAND OR EQUAL WEATHER EXTERIOR providing a weather -resistive barrier, insulation, or for aesthetics, including but not limited to, veneers, siding, exterior insulation and finish <br />PROOF CAULKING CEMT. FIN. systems, architectural trim and embellishments such as cornices, soffits, and fascias. <br />SELF -ADHERED FLASHING BUILDING PAPER <br />WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or <br />SUBFLOOR other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied <br />77 horizontally, with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less <br />than 6 inches (152 mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and <br />RIM JOIST building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />Vi <br />R703.7.3 Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based sheathing, shall <br />1 include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The individual <br />7f <br />2 Q layers shall be installed independently such that each layer provides a separate continuous plane and any flashing (installed in accordance <br />with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance equal to or greater <br />SELF -ADHERED FLASHING than that of 60-minute Grade D paper and is separated from the stucco by an intervening, substantially nonwater-absorbing layer or <br />1 CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER 1 designed drainage space. <br />MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />INSTALL SELF -ADHERED NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall <br />FLASHING JAMB & HEAD THROUGH SELF -ADHERED cavity or penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with <br />FLASHING, SEE FLASHING SELF -ADHERED FLASHING -"- <br />LASHING AAMA 711. All exterior fenestration products shall be sealed at the juncture with the building wall with a sealant complying with AAMA 800 or <br />FLANGED WINDOW <br />(SEE DETAIL WP01) ASTM C920 Class 25 Grade NS or greater for proper joint expansion and contraction, ASTM C1281, AAMA 812, or other approved standard <br />SCORED as appropriate for the type of sealant. Fluid -applied membranes used as flashing in exterior walls shall comply with AAMA 714. The flashing <br />RELEASE PAPER shall extend to the surface of the exterior wall finish. Approved corrosion resistant fleshings shall be installed at the following locations: <br />SELF -ADHERED FLASHING, �`o (BEFORE FOLDING, SCORE 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />EXTEND A MINIMUM 6" RELEASE PAPER TO EXPOSE <br />ADHESIVE AS SHOWN) finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />VERTICALLY FROM <br />BOTTOM OF shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />THRESHOLD following: <br />1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or <br />details are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be <br />2 sealed or sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier <br />for subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />5 1.2. In accordance with the flashing design or method of a registered design professional. <br />4 1.3. In accordance with other approved methods. <br />6 1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA <br />400. <br />2 7 2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />SELF -ADHERED FLASHING 03. Under and at the ends of masonry, wood or metal copings and sills. <br />INSIDE CORNER , • <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />-7 <br />Ground7 6. At wall and roof intersections. <br />lz� 7. At built-in putters. <br />:LF-ADHERED FLASHING <br />,TCH <br />HERED FLASHING <br />2 <br />14 <br />5 <br />1 <br />W \ <br />Cn <br />Q <br />Z ' \ <br />io_ a <br />MI I <br />LU OW.. PLASTER STOP <br />co <br />_ U) CONTINUOUS BACKER-� <br />U ROD & SEALANT <br />LLJ LI <br />2 � <br />W <br />IV)] 0 <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />r <br />DRAINAGE PLANE WRB <br />> <br />• <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />J� <br />I� <br />�Il <br />THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. <br />DO NOT SEAL. <br />DRIP SCREED PLASTIC <br />ACCESSORY <br />R:1i199111 06LP►k-RF:WA 7 <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) o 0 <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING,'OSB', PLYWOOD, DENSGLASSttS <br />FRAMING <br />SHEATHING <br />ANE WRB <br />WRB <br />FHESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />.Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />0 <br />0 <br />N <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineers signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />H <br />Q <br />a0 8 <br />p14 p <br />Go <br />N <br />ti <br />Lo <br />y r co:000 <br />01 y <br />U. <br />4* <br />N <br />7� <br />rnr- -0 <br />J W <br />LL- a <br />""Z <br />yfNMM <br />W. rn <br />a <br />13 <br />J LL LL <br />a IY <br />C0 <br />Lf6o <br />O <br />-t-- C�'�; <br />:3 M <br />MCOQ <br />mom <br />W <br />2 rn . <br />¢ <br />¢ a <br />W N O <br />� Z <br />a'Ln <br />N <br />Z <br />W <br />z <br />z <br />Q <br />J <br />a � <br />N <br />z <br />� <br />U <br />g <br />O <br />,� s <br />N <br />c y <br />V) <br />in <br />f6 <br />r- <br />pEp <br />I <br />O <br />wwZ <br />o <br />U- <br />E <br />oo <br />Q <br />E OU <br />z® <br />oa <br />rca og <br />=° <br />ZO <br />04 <br />L <br />a o <br />Q <br />¢a <br />aZ <br />W ro <br />C <br />C <br />O <br />x <br />U <br />w OJ <br />m E <br />o <br />Z � <br />1Z <br />Z <br />....T <br />N J <br /><a <br />W <br />Ey <br />N <br />F <br />Z2 <br /><o <br />a <br />w <br />w <br />W <br />U <br />j < <br />k <br />yLL <br />w� <br />=3 <br />J <br />o;o <br />cfl <br />a x <br />�U3 <br />V <br />ZI <br />ca <br />W <br />ca <br />d% <br />T' <br />W m <br />o <br />Cy) <br />Ln <br />r <br />.L <br />U.)T <br />N <br />T <br />am <br />E <br />�-- <br />N r <br />Z <br />f6 <br />Z <br />E <br />E <br />W <br />m <br />d <br />E <br />U -1 <br />-o A3 <br />Q p <br />c <br />c <br />JOB <br />NO: <br />20-8067 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />W P <br />