My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2831 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2831 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 11:26:10 AM
Creation date
2/28/2025 11:03:14 AM
Metadata
Fields
Template:
Building Plans
Street #
2831
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
1025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- — -- I I 1 11 1 ■ I I _ I _ I_ - I I I I I I I ►° III 1 11 111 11 1 1 ' 1— — 1 —0 <br />CROSS BRACING DETAIL (TYP.)r1 <br />SCALE: NTS <br />TRUSS NOTES: <br />CONV. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. CB <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. pg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT SEE TYP TRUSS BLOCKING DETAILS <br />vv/ L- I vu ` "/' l I I I 1 V v v "L <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLOCKING NAILED @ <br />- EACH SIDE w/ (3) 12d NAILS <br />WHEN REQUIRED w/ (2) <br />SIMPSON HTS20 w/ (24) 10d x <br />1 1/2" NAILS EACH <br />�3 <br />TB <br />PRE-ENG. TRUSS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP — <br />MAX & EACH END ALTERNATE ^ CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIRECTION TYP. A I <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />TRUSS <br />:33 <br />SEE ROOF <br />PLAN SHE <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />N TRUSS <br />(2) 2x8 #2 SYP wl <br />O.S.B. FLITCH PI <br />TOP @ TRUSS B <br />U.N.O. ON ROOF <br />PLAN <br />NOTE: PENDING BEAM <br />BEARING LOCATION, THE <br />BEAM CAN SIT ON TOP OF <br />COLUMN w/ (2) SIMPSON <br />HTS20 w/ (24) 10d x 1 1/2" <br />NAILS EACH <br />SIMPSON HU46/HUC46 w/ (8) <br />16d NAILS TO POST & (4) 10d <br />NAILS TO BEAM <br />SUPPORT COLUMN BUILT-UP <br />(2) 2x4's OR 4x4 w/ (2) 10d <br />NAILS @ 8" O.C. EACH PLY <br />(SHOWN AS 4 x 4) <br />JACK TRUSS (AS SHOWN) <br />OR GABLE END SEE TRUSS <br />LAYOUT <br />CLIP EACH TRUSS <br />(SEE ROOF PLAN <br />FOR TYPE) <br />FRAME OUT TO <br />BLOCK EDGE <br />SEE PLAN <br />FOR BEAM SIZE <br />EXTERIOR SHEATHING <br />(2) SIMPSON HETA20 w/ (8) 10d ATTACHED PER NAILING <br />TYPICAL BLOCK x 1 1/2" NAILS EACH - OR (2) SCHEDULE <br />�K WALL SIMPSON MSTAM36 w/ (7) 10d 2x SPF #2 <br />USSES GIP & (4) 1/4"x2 1/4" TITENS EACH L] <br />AT 16" O.C. <br />(2) 12D NAILS — <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 (2) #7 x 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO TIE BEAM <br />2X4 CONT. AT—/ CONC. MASONRY <br />T & B CHORD 0 STEEL OR WOOD <br />BEARING SUPPORT <br />A —A ALTERNATE BLOCKING <br />DETAIL a@ INTERIOR BEARING 3 <br />WOOD TRUSS <br />A PROVIDE BLOCKING AT ALL TRUSS BEARING SCALE: NTS <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />TYP. WOOD TRUSS BLOCKING DETAIL STANDARD HEEL HEIGHT <br />SCALE: NTS <br />SIMPSON LSTA18 <br />w/ (12) 10d NAILS <br />CENTERED AT <br />SPLIT TO TIE <br />BEAMS TOGETHER <br />SEE FLOOR PLAN <br />FOR COLUMN SIZE <br />& ADDITIONAL INF( <br />SCALE: NTS <br />'IMPSON HUC410 w/ <br />6d INTO HEADER & ( <br />Od INTO BEAM - SEE <br />2OOF PLAN FOR MOI <br />VFO <br />SEE FLOOR PLAN FOR <br />TIE BEAM <br />BEAM a@ RAISED ENTRY <br />MASONRY WALL 4 <br />SCALE: NITS <br />SEE PLAN <br />FOR CANT. <br />COLUMN SIZE & BASE 7/16" OSB FLITCH PLATE <br />CONNECTION INFO REQ'D ONLY WHEN <br />INDICATED ON BM. <br />7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR SCHEDULE/PLAN <br />REQ'D ONLY WHEN COLUMN SIZE & BASE <br />OPTION A INDICATED ON <br />SC EDULE/PLANM OPTION B CONNECTION INFO OPTION C <br />COMMON BM. TO POST ATTACHMENT <br />SEE ROOF PLAN <br />FOR BEAM SIZE & <br />CONNECTION INFO. <br />SIMPSON MTS18 w/ (14) <br />10d NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />A � A <br />SEE PLAN FOR <br />SEE PLAN FOR <br />CANTILEVER IF <br />INDICATED <br />CORNER G SEE FOUNDATION <br />PLAN FOR MORE INFO <br />5" <br />COMMON BM. ATTACHMENT <br />SCALE: NTS <br />SCALE: 3/4"=V-0" <br />im <br />MIDDLE <br />BM. SPLICE OVER <br />CENTER OF POST <br />BUILDER FRAME <br />RADIUS <br />AS REQUIRED <br />KNEEWALL c"D ENTRY FRONT WALL <br />SCALE: NTS <br />2x4 #2 SYP NAILER. NAIL <br />TO STUDS w/ (3)16d AT <br />EACH STUD - TOENAIL ROOF AND EXTERIOR <br />EACH TRUSS TO NAILER SHEATHING ATTACHED <br />w/ (3) 10d PER NAILING SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />w/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY <br />w/ (3) ROWS OF 16d <br />NAILS AT 24" O.C. <br />SIMPSON LUS26 w/ (8) 10d NAILS —' <br />OR IF 2 PLY TRUSS SIMPSON <br />LUS26-2 w/ (8) 16d NAILS TO <br />SEE FLOOR FRAMING PLAN <br />LEDGER <br />AND J/S6 FOR MORE INFO. <br />2X10 #2 SYP CONT. LEDGER w/ (3) <br />VERIFY WITH PLAN FORLOCATION AND DIRECTION <br />1/2" X 4 1/2" LAG SCREWS ATTACH <br />(IF PARALLEL SEE 2/D2 FOR <br />LAG SCREWS INTO END OF EACH <br />BLOCKING INFO) <br />FLOOR TRUSS, 24" O.C. MAX. (AT <br />EACH SIDE OF G.T. INSTALL (4) LAG <br />MASONRY WALL <br />SCREWS EACH SIDE) <br />(TYPICAL) <br />SECTION AT LOW <br />ROOF 9 <br />SCALE: NTS <br />AI <br />VARIES -, Zr- -r r_z,�ts,-- 2x STUDS @ 16" O.C. <br />ROOF SHEATHING SEE 1/S5 FOR ti w/ SIMPSON SP1 w/ (10) 10d <br />ATTACHED PER - -- ADDITIONAL SEE PLAN FOR <br />NAILING SCHEDULE OUTLOOKER 8d NAILS AT VALLEY TRUSS NAILS AT BASE <br />1Od NAILS ATTOP <br />2x4 #2 SPF BRACING @ 4" O.C. INFO. SP2 w/ 12 1 <br />EXTERIOR SHEATHING INFO. <br />16" O.C. W/ 4 12d 2x BLOCKING BETWEEN STUDS <br />O —�-- —1/I— COMMON TRUSSES. ATTACHED PER � TO TRUSS W/ (2) 12d TOENAILS <br />TOENAILS TO TOP - SEE TRUSS PLAN 2x4 STUDS w/ SIMPSON NAILING SCHEDULE <br />PLATE & (2) 12d END MIN. (2) 2x4 FOR CONNECTION SP1 w/ (10) 10d NAILS EACH END ( BETWEEN TRUSSES <br />STRUCTURAL SHEATHING NAILS TO TRUSS <br />ATTACHED PER NAILING SPF TOP INFORMATION. AT BASE SEE J/S6 FOR GABLE (2) 12d NAILS TO EACH VERTICAL <br />LOW ROOF/WALL <br />SCHEDULE BOTTOM CHORD PLATE MORE INFO. ` TRUSS SHEATHING ATTACHED STUD) <br />PER NAILING SCHEDULE 2x BASE PLATE W/ 2 12d <br />VARIES SEE PLAN ( ) <br />_ VARIES W/ FOR WALL LOCATION 2x4 BASE PLATE W/ 1/2" PLYWOOD NAILS @ 16" O.C. ALONG W/ <br />ROOF SLOPE - SIMPSON LSTA30 w/ SIMPSON MTS12 w/ (14) 10d x <br />(22) 10d NAILS OR (2) 16d NAILS TO 1 1/2" NAILS TO BLOCKING <br />hter'- SIMPSON MTS12 w/ EACH COMMON BELOW 16" O.C. <br />WOOD WALL - _ -__ . <br />OR TRUSS. 2X4 CONT. W/ (2) MIN. 2x4 #2 SPF STUDS @ (14) 10d x 1 1/2" NAILS TYP TOP &BON OM y.-r / @ <br />TO FLOOR GIRDER <br />16" O.C. W/ EXTERIOR 1 - - -_� rl - <br />SEE PLAN 16d COMMONS i <br />NAILS EACH v SHEATHING ATTACHED BELOW @ 16" O.C. <br />STUD TYP. T&B PER NAILING SCHEDULE & • MASONRY WALL BELOW: SIMPSON PLYWOOD <br />(3) 12d TOENAILS TO HETA16 w/ 9 10d x 1 1/2" NAILS <br />TRUSS OR SEE PLAN FOR PLATE BELOW -- -� O @ <br />MASONRY WALL 4'-0" O.C. TO GABLE TRUSS FLOORING <br />ROOF SYSTEM TOP OF WALL OR BEAM . BEAM BELOW: SIMPSON HTS20 w/ <br />SEE TRUSS PLAN A <br />(24) 10d x 1 1/2 NAILS @ 4 -0 O.C. ---- <br />o MIN. 2x4 #2 SYP P.T. PLATE 16" FLOOR SYSTEM FLOOR GIRDER <br />W/ 1/2"X8" EPDXY ANCHOR SEE PLAN FOR SEE PLAN FOR TO GABLE TRUSS LOW ROOF TRUSS W/ (2) 2x6 BLOCKING UNDER FLOOR G.T. <br />MASONRY WALL SEE @ 3" FROM EACH END & DIRECTION CONNECTION COMMON TRUSS RAISED BOTTOM CHORD 2nd FLOOR WALL w/ SEE PLAN <br />PLAN FOR MORE 16" O.C. MAX. �° SEE ROOF PLAN EXTENSION SEE TRUSS SIMPSON LUS24-2 w/ (16) <br />SHEAR TRANSFER INFO. °� SECTION @FLOOR FOR CONNECTION CONNECTIONS TO G.T. 16d NAILS AT EACH END <br />EXTERIOR. WALL SECTION ENTRY $ CONNECTION 22 SECTION AT HIP GABLE 12 SECTION BUMP OUT 39 <br />SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS <br />SCALE: NTS <br />DETAILS & SECTIONS <br />1 N I � � i►l�iri <br />\\e��ti���tttt <br />O Vti N <br />5 <br />O F E S s <br />O <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />1.�2pp <br />LQ <br />8 N N ik <br />N <br />IM 07�� <br />01 �j N J <br />N J it W <br />tl! <br />a <br />to r- LL LL a <br />y M M L Wuj <br />� La a <br />Z <br />C. @0,00 <br />r C. o <br />m O <br />W0 <br />M <br />¢ � 4 <br />I <br />Z LL <br />(a <br />Jco <br />C0z <0 <br />N <br />OU ❑❑❑ <br />W <br />CD cm, <br />(D <br />z QN p� <br />z � S <br />Z <br />Q � <br />J <br />a. <br />U <br />N <br />V) <br />z a <br />0 <br />i <br />4-1D* <br />U <br />cn <br />0 a <br />R <br />8 <br />N <br />c N <br />co <br />LL, <br />E <br />I <br />C) o <br />c u) <br />. <br />—o <br />N <br />see <br />C"::)w <br />M <br />0 <br />o <br />Z <br />a <br />J <br />V- <br />E <br />y 5 <br />o <br />Zo <br />411"'- <br />:z <br />V <br />W i <br />¢� <br />® <br />oa <br />w 0 <br />z <br />r6 <br />N <br />o <br />x ' <br />�< <br />� <br />j O <br />O W <br />a <br />wWm <br />.�-. i <br />o <br />�d o <br />0 <br />CO CY <br />U <br />N Of <br />Oz <br />Z <br />v� <br /><� <br />Q W <br />�Z <br />d 3 <br />oa <br />Z o <br />g <br />Q <br />¢ <br />NW <br />a_ <br />W <br />ci <br />Z <br />o <br />co <br />c <br />zla <br />° r a <br />3 <br />M <br />� <br />W <br />O <br />CCL <br />O <br />^ V <br />W m <br />= <br />� <br />T <br />0 p <br />� <br />J N <br />T <br />r <br />m <br />T— <br />N <br />o <br />Z <br />z <br />E O <br />iri <br />to <br />a <br />E <br />O <br />0 ° <br />i <br />¢ o <br />C <br />JOB <br />NO: <br />20-6579 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />D1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.