ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY; <br />BON <br />TERMINATION PER <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />upper to fights & outlets <br />upper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />i Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217, <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PEPP <br />DUPLEX OUTLET ABOVE COUNTER <br />WP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />P4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />�Q <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />T 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W! ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />6� <br />(1) PHONE LINE, (1) DATA PORT <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H.B. <br />it.' n VERIFY LOCATION " IRRIGATION <br />ELECTRICAL PANEL GFI @ 44" A.F.F. I I <br />OPT. I <br />FAM I LY F�M GF _ _ --w. _ \ <br />\ \ \ 2 CAR GARAGE <br />ROUGH -IN FOR I I <br />OPT. CLG. FAN/ GF <br /><IGHT PRE -WIRE — ---— <br />IN, <br />¢=¢a <br />t1/ �IIIIIIIII <br />GARAGE <br />_ Zi aI DOORS-4 GFI @ GFI44" <br />A.F.F. U <br />GFI CfI <br />U.C. SWITCH <br />FOR DISPOSAL OIIIIIII IIIIIIII TI <br />xvi0— 4or <br />I I I <br />ENTRY <br />J I FI <br />I I v I 4 I I I <br />W.H. GFI @44" L — — — — — — — — — — — — <br />PATIO I `1 A.F.F. <br />CAFE I �Il.W.J I I --------- <br />C-J� _ 1 <br />GFI 3 3 T 3 <br />DEDICATED RECEPTACLE �' — <br />I I <br />\ FOR MICROWAVE RANGE FOYER <br />1 � HOOD PER SPECS \ <br />°° <br />to WP I <br />WP <br />I I <br />GFI j GFI I I <br />---- W.I.C.--i-------------- ------------------ <br />HU I O <br />/ I S.D. � I S.D. <br />S.D. <br />�M I S.D. <br />OWNER RECEPTI BEDROOM 3 <br />/ SUITE FOR I ROUGH -IN FOR <br />1 / SYSTEM I LOIGHT PRE -WIRE ! BEDROOM 2 <br />ie//2OPT OPT. FAN/ <br />FOR <br />DISC. 4 I ROUGH -IN FOR 1 _ �`� ` \ ��' \` LIGHT PRE-WIRI <br />OPT. CLG. FAN/ / G <br />WIP I LIGHT PRE -WIRE <br />GFI = 1 VP \ \ <br />00, <br />EP)AD <br />;H <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />r <br />lL � <br />r <br />s <br />Z N O <br />z <br />o <br />U)V)z <br />' 2 <br />^' V LL <br />W <br />t � �, <br />T US Yo <br />� <br />U a <br />W I- <br />N C E <br />0. <br />N <br />�N <br />U CO <br />w rn <br />~ 2 EE <br />0 c <br />_� <br />U e, <br />¢ 0 <br />� m <br />N N <br />v�1 N <br />o� <br />vi ooN o w Z <br />Z <br />�Z �-:i m z o w <br />a <br />LU W 4 z <br />45 s O E <br />Z O a¢ O <br />Nam" m <br />N o <br />V NLL <br />Z <br />Lil N a 8 c Q <br />O U U <br />❑❑ <br />rn <br />0 <br />N <br />M <br />ti <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer s signature and seal <br />o <br />M <br />w <br />M <br />M <br />w <br />o <br />z <br />LL_ <br />o E <br />oCU <br />oo <br />z® <br />oa <br />o E <br />K O <br />a< <br />o <br />0 O <br />°< <br />aZ <br />Ccli:)<o <br />ITT <br />to <br />z <br />Y <br />U <br />w 19 <br />m 0 <br />0 , <br />Z <br />Q W <br />MINE <br />Z Z <br />ao <br />>O <br />MillCD <br />d <br />w <br />z¢ <br />a <br />3 <br />C <br />,O f� <br />'M <br />L <br />\W <br />/ <br />._ <br />Ln <br />CM <br />a) <br />> <br />TT <br />O <br />Q <br />� <br />co <br />2 C <br />m O � <br />VJ <br />T <br />Ln <br />T <br />C:)�+ <br />' ^ <br />r <br />L.0 t) T <br />T— <br />iff <br />w CO M co <br />o <br />M <br />Z <br />� T— iri j <br />E W <br />z <br />to <br />@ <br />a <br />U _j Q p <br />c <br />c <br />JOB <br />NO: 19-5334 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />r" <br />