RIDGE <br />ATTIC VENTILATION CALCULATIONS - 131 <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />22.00000 <br />2.000000 <br />Floor <br />2002 <br />1922 <br />275 <br />961 <br />69 <br />480 <br />0 <br />606.0 <br />330.0 <br />276.0 <br />(Zone 1) <br />**NOTE** <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED, RESIDENTIAL. <br />ROOF PLAN. <br />SCALE:1/4'=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />**CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN, OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />uul <br />c� <br />0 <br />V M <br />0 0 <br />z o <br />J l7 <br />d <br />N z o <br />`V W O <br />w 0 <br />N E <br />C6 �— <br />U 0° <br />w <br />— T E <br />o g <br />= <br />U o' <br />c "' <br />° <br />Q¢ <br />i14 <br />d <br />o o w Z <br />Z <br />�r U <br />a E �* z a s <br />LLU <br />U <br />Ck <br />zIIWci¢Qo <br />S g v a w 1 O O <br />13 V1 <br />Z ��➢PP <br />` �' E/ � Q <br />W +•' e# O <br />,�. ,.. S <br />CN <br />CCff�6b <br />MMh1��. <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />r_ <br />CD <br />co <br />Q <br />Z <br />M <br />z0 <br />< <br />41 <br />U_ <br />E U <br />zo <br />a� <br />T ° <br />`R <br />9 (6 <br />KO <br />"0 <br />OO <br />O E <br />CV <br />N L <br />to <br />i <br /><o <br />adz <br />Z <br />�-1 <br />m� <br />(� <br />c <br />O Y <br />U <br />N <br />O <br />Z <br />[n <br />a <br />< <br />Q W <br />Z <br />Cn <br />O Q <br />Z¢o <br />J U <br />a <br />w <br />¢p <br />oLL <br />F_ <br />=3 <br />CD'o <br />O <br />�w <br />w <br />zla <br />a� <br />o 3 <br />C <br />o T <br />M <br />nL' <br />W <br />LO <br />'- <br />CM <br />E (1) <br />> <br />T <br />0 <br />^�� <br />CL <br />U C <br />9 0 <br />co <br />V <br />r <br />L0 <br />L0 <br />■TT� _J r <br />r <br />a) N <br />.L LO T <br />r <br />ui <br />N <br />M CO M <br />o <br />E <br />E T iii <br />Z <br />Z <br />E <br />ai <br />c <br />r1 <br />o <br />U _J Q p <br />c <br />_J <br />JOB <br />NO: 19-5334 <br />SCALE : AS NOTED <br />SHEET NO. <br />5.0 <br />