W1 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />914 copper to lights & outlets <br />1 <br />200 10 #12 copper to 20 amp ckts <br />00 AMP <br />10 <br />#10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER AIu <br />200 amp <br />150 amp <br />POWER CO. FEED—` <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine, Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FPP <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />3 <br />THREE-WAY SWITCH <br />?4. <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />F••O <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />rO <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />f [efP <br />PUSH BUTTON SWITCH (OPTIONAL) <br />[]D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />f USB <br />TELEPHONE/USB (OPTIONAL) <br />N <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />/l] <br />ELECTRIC METER <br />ELECTRIC PANEL <br />—�I <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />Q, <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />H.B. <br />DISC. b <br />1 ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />I LIGHT PRE -WIRE <br />12 <br />*NER'S <br />FOR I <br />ALARM I <br />SYSTEM <br />I <br />V" C. <br />I <br />---------- -� <br />W <br />I 1 <br />WP / <br />GFI <br />00 <br />� I <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />I <br />I <br />PATIO <br />I <br />I <br />I <br />/ I <br />I <br />I <br />I <br />I U.C. SWITCH - <br />FOR DISPOSAL <br />I <br />I � <br />I r <br />/ I — r — — <br />/ ROUGH -IN FOR <br />/ OPT. CLG. FAN/ <br />LIGHT PRE-WIRE <br />FAMILY 5M <br />/ <br />/ <br />/ <br />/ <br />/ <br />F- OPT. -1 <br />--REF. -. <br />U% <br />-_ G- �rn�r■w <br />LIGHT PRE -WIRE <br />---OPT. A�■�� <br />1!!I!�h.- <br />LIGHT PRE -WIRE <br />■ EMMI,;;PZI BEDR06M 2 <br />_ II II _ �u - � • �l► _ _ _ II II _ <br />■�LIDA <br />— <br />1rWP j <br />�.--_-� FOYER — GFI <br />i <br />�e <br />GFI @ 44" <br />W.H. <br />7 <br />A.F.F. <br />F ------------ <br />O <br />I <br />n � <br />I <br />I r <br />I <br />I ►M I <br />I <br />I I <br />I <br />I <br />t / QC) <br />I <br />GFI @ <br />/ l- w 11 <br />44" <br />U) <br />I GARAGE <br />A.F.F. <br />w w 41 <br />I DOOR <br />W n. <br />GFI <br />I <br />i <br />22 AR GARAU E <br />I <br />I <br />I <br />I <br />I <br />VERIFY LOCATION <br />I <br />—IRRIGATION — — — — — <br />ELECTRICAL PANEL <br />gFI @ 44" A.F.F. <br />VERIFY METER H.B. <br />LOCATION WITH <br />BUILDER <br />ENTRY <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />lu! <br />zcc g <br />z g <br />o <br />M <br />V) <br />vCD <br />4--' "' (d <br />� w o <br />o a <br />0 LU <br />U) E <br />�N � <br />o <br />� � <br />LU <br />E <br />all= o g <br />U � 55 <br />c rn d <br />• <br />010 <br />0, <br />N <br />■.Y.w'■ g o N o <br />Z <br />C fsn <br />F M � U) <br />in"J-9 �' a <br />W �Z <br />0S1kLu <br />� o <br />uj�._ on <br />v 2 E mZ Z — LL� C� <br />aNa"'� <br />W 8 <br />6 . v <br />❑❑ <br />Cn <br />0 <br />CV <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />o <br />W <br />O <br />Z <br />Z <br />< <br />u <br />LQ E <br />E <br />wo <br />-0 <br />wz <br />Z <br />6N <br />z® <br />❑a <br />CC1 <br />G p <br />U <br />F ro <br />O <br />aO <br />az <br />'0 <br />a <br />wZ <br />CV <br />L <br />Ww(� o <br />QO <br />o <br />mi <br />(d <br />N = <br />- <br />U <br />ym <br />U <br />a� <br />Z <br />Z <br />iz Q% <br />_I <br />,� <br />Q W <br />�m <br />23 <br />a <br />C) <br />LLa <br />U <br />Q. <br />yw <br />W <br />o <br />yu <br />=� <br />C <br />0 <br />o <br />Z <br />7 <br />a r <br />V <br />ai <br />zl¢ <br />3 <br />�0 <br />> CM <br />L <br />> <br />■� <br />M <br />ryo <br />M <br />r <br />Q <br />C o <br />CV <br />co <br />T� <br />' / <br />� o oo,, <br />m <br />Vr+ <br />LO <br />�� <br />�' <br />O <br />L <br />r <br />M N <br />'— <br />E <br />M C') <br />r M <br />Z <br />' <br />E Q y <br />E <br />0 <br />.• <br />U J Q to <br />J <br />JOB <br />NO: 19-5332 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />