My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3323 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3323 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 3:40:46 PM
Creation date
2/28/2025 11:07:05 AM
Metadata
Fields
Template:
Building Plans
Street #
3323
Location
Lytton Hall Dr
Contractor
Lennar Homes
Building Plans - Permit #
21908
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTIC VENTILATION CALCULATIONS <br />- Al <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />(No Upper Ventilators <br />1/300 Rule <br />Ridge <br />Vent Amt <br />Off -Ridge <br />Req.) <br />(Must Provide Upper Ventilators) <br />(Ft) <br />Amt. <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />ventilation Of vented <br />IN. of <br />of <br />vented <br />ventilation to <br />be provided <br />. <br />SQIN. of <br />SQ. IN. of <br />Ventilators <br />(See Elev ) <br />required soffit <br />ventilation <br />soffit <br />by upper <br />ventilation <br />Ventilation <br />needed <br />required <br />needed <br />ventilators <br />Main <br />23.00000 <br />1.000000 <br />Floor <br />2008 <br />1928 <br />275 <br />964 <br />69 <br />482 <br />0 <br />483.0 <br />345.0 <br />138.0 <br />(Zone 1) <br />**NOTE** <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN <br />SCALE: %4=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following, <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 11150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />**CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />Q <br />M <br />v a <br />¢ M <br />a <br />m <br />z to <br />t11 a <br />v w <br />_0 <br />Cl3 Y <br />W � <br />0 <br />o a <br />*O <br />0 <br />UJ <br />U `° <br />LU <br />r—T 8 <br />o <br />z <br />= <br />iJ ' <br />0 <br />■. <br />soli <br />N N <br />U) <br />ZU) <br />'... yJo p� W w <br />W -H� H' a <br />_ <br />o <br />Sao <br />Z OIL <br />� O <br />�4 a <br />G` <br />0 • <br />s <br />'fit` P'20 ..• Or! .�R1.- <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />o <br />M <br />� <br />z <br />LJ <br />m� E <br />z <br />0 <br />o <br />a' <br />z E <br />Z" <br />O <br />E <br />N <br />I_ r0 <br />S 0 <br />xU <br />00 <br />a <br />— <br />O E <br />N <br />aF <br />o <br />q p <br />0� <br />dz <br />J <br />fu <br />C <br />gz <br />O Y <br />V <br />m� <br />O <br />Z <br />U3 J <br />wm <br />(7� <br />QW <br />OLL¢ <br />zqJ� <br />g. <br />OEM <br />C) <br />'�Z <br />�W <br />o <br /><¢CD <br />}O <br />fI <br />zl¢ <br />a <br />�U 3 <br />C C)O <br />;n <br />L <br />,> <br />M <br />_ <br />X N <br />T <br />C o <br />N <br />F- <br />_ <br />fir <br />in 0LO <br />•T� .J r <br />v ^ <br />r <br />i C O N <br />a� <br />E <br />M co <br />4 N <br />o <br />Z <br />E O N <br />N <br />C <br />C <br />d <br />U ° Q p <br />JOB <br />NO: 19-5332 <br />SCALE : AS NOTED <br />SHEET NO. <br />5.0 <br />