My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3335 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3335 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 3:46:03 PM
Creation date
2/28/2025 11:07:10 AM
Metadata
Fields
Template:
Building Plans
Street #
3335
Location
Lytton Hall Dr
Contractor
Lennar Home
Building Plans - Permit #
21903
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, , 1,rr"I ,.,I II - - - ,, r r _ -- - <br />IELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />11 M14 copper to lights ii outlets <br />t <br />200 01 g12 copper to 20 amp ckts <br />00 AMP <br />10 <br />x10-2 copper to WH <br />10 p 10.3 copper to Dryer <br />METER <br />�5 2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED—�� <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />Bare Cu Ground <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />WP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />piiiF <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24. <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />FP <br />PUSH BUTTON SWITCH (OPTIONAL) <br />H9 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />89 <br />(1) PHONE LINE, (1) DATA PORT <br />WP DISC. DEDICATED RECEPTACLE <br />GFI H.B. FOR MICROWAVE RANGE <br />A t HOOD PER SPECS <br />\ 3 GFI ' GFI I <br />AC PAD — — _ — — <br />ROUGH -IN FOR <br />\ / RANGE ` / OPT. CLG. FAN/ I / <br />PENDANT AS / \ / LIGHT PRE -WIRE <br />\ PER SPECS / AdkL � T �% I O <br />i U. . S IT H ROUGH -IN FOR /� <br />!� I^ ' ROUGH -IN FOR <br />- I OPT. CLG. FAN/ I OPT. CLG. FAN/ <br />\ INK /DIS I IGHTPRE-WIRE �\ G I <br />AFE ` I D.W. o j GFI ��� BED�OOM l ' BE(jR6OMR4 IRE <br />\ 11 I I � 1 <br />❑ 1 <br />PA �O \ _GFI ---_-- GF BEDROOM 2\`� �\ l / <br />GFI �- - OPT, I \ S.D.O F <br />REF. <br />qP I <br />U.C. OUTLET S.D. <br />C.M <br />S.D. LM <br />U.C. OUTLET — — — — — — — — S.D. � �. '" <br />FORDW <br />ROUGH-IN FOR <br />OPT. CLG. FAN/ \ WP <br />LIGHT PRE -WIRE _ _ GFI I <br />12 <br />M FO <br />i ENTRY <br />�FA RM ��\ <br />\ CH <br />l GFI @ 44" <br />/ AHU A.F.F. <br />— _ F------------ <br />V. <br />�_-- I I <br />ndb <br />T <br />I I I <br />I 11 I I I I <br />`_V_ - I <br />\ o VP ----------- <br />I I <br />S.D. <br />\ I GFI @ 44" I I I <br />ROUGH -IN FOR A.F.F. I I <br />OPT. CLG. FAN/ GFI FOR I I I <br />\ LIGHT PRE -WIRE \ GAR. DOO I I <br />12 \ — i GFI 1 I I <br />% I 2 CAR GARAGE <br />I I I <br />OWNER'S SUITEaim W .C. � <br />I I I I I <br />I i I I I I <br />I O I I I <br />-7 VERIFY LOCATION j I I <br />_ _ _ _ _ J ELECTRICAL PANEL _IRRIGATION <br />GFI — — — — A �� _IRRIGATION <br />RECEPT. <br />FOR ALARM VERIFY METER H.B. <br />SYSTEM LOCATION WITH <br />BUILDER <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4"=1'-0" <br />f� <br />2i <br />C-- u <br />I /ILM� <br />z � <br />g <br />z <br />z g <br />Q - <br />ti N <br />_ M <br />U) L <br />N z <br />^, o <br />VJ _ LL <br />fl= Y <br />�U <br />Ow � <br />N c <br />t/> <br />a <br />� � <br />U 00 <br />W e <br />0 8 <br />d <br />c rn <br />� g � <br />r. <br />Q <br />Sm <br />N N <br />Z <br />zLL4o <br />LU -�i� tiz nm <br />'C <br />_ <br />N La. ta] <br />W � ¢' € gQ � z <br />Z ��a33` 0001 <br />� m m <br />ci N@-: Q <br />a :@ iv <br />W Na"= d o <br />LLMZ <br />O V 1 U E— <br />❑ ❑ <br />�I rn <br />0 <br />' CV <br />0 <br />M <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />o <br />Mi <br />w <br />ZZZ <br />F <br />Q <br />I <br />;? Eg <br />0 <br />E V <br />�o <br />oLL <br />» <br />=® <br />oa <br />_ <br />M O <br />U� <br />a0 <br />U O <br />o g <br />Z <br />O E <br />N <br />° <br />ao <br />aZ <br />m <br />_tow� <br />Ox <br />U <br />ym <br />Zza�_ <br />Q1 <br />J <br />coU <br />3 <br />j <br />O <br />Q W <br />f N <br />o <br />W <br />Q <br />T <br />V <br />LLa <br />sa <br />ao <br />�w <br />G <br />�z <br />o <br />w� <br />>O <br />cfl <br />za <br />a r <br />03 <br />0 <br />C O <br />2 <br />^L` <br />W <br />i <br />e— <br />N <br />M <br />N <br />T <br />a <br />o <br />cco <br />T <br />C <br />O <br />a� <br />T <br />J r- <br />LO <br />T <br />N M N <br />COCV) a) <br />'— <br />E <br />m; <br />Azc�v <br />Az <br />o <br />Z <br />E O <br />E <br />`m <br />c <br />d <br />U -j Q <br />JOB <br />NO: 19-5331 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.