Laserfiche WebLink
'I' 11111111 l III I'I r 111'NET 11 111 � I <br />GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 174" and <br />longer with a nominal height of 8" meet or exceed U180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8, Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10, Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load �� O <br />Safe vertical load Safe horizontal load <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />I 0 0 <br />8F44 1 B/1 T 81=40 1 B/1 T 8RF40 OB/1T 8F32 1 B/1T <br />FORM & GROUT SOLID <br />(V cQ[ <br />O c� W <br />O #5 BAR CONT. <br />8F12-1 B/1 T <br />O <br />"V" LINTEL DETAIL <br />SCALE = N.T.S. <br />Iml <br />E <br />�re <br />TYPE DESIGNATION <br />F = FILLED <br />WITH <br />GROUT / U = UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />8F16- <br />B/1 T <br />U <br />Q <br />00 <br />tNOMINAL. <br />tQUANTITY OF <br />WIDTH <br />#5 REBAR AT <br />TOP <br />NOMINAL - <br />HEIGHT <br />MATERIALS <br />77Tc_p_re_c`a­sF = 3500 psi. <br />2. f c prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg - 3000 psi w/ <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />#5 EBAR .(1)RE <br />MIN. <br />AT TOP <br />(1) REQ'D <br />CLEAR <br />ALTERNATE POWERS <br />STEEL LINTEL <br />- <br />n <br />a O e <br />#5 REBAR AT TOP <br />2 <br />c <br />° <br />.M.U. <br />e' a <br />MIN. (1) REUD <br />1-1/2" CLEAR <br />a <br />z <br />a <br />O d A <br />° a <br />M <br />z <br />GROUT <br />n <br />rn ¢ <br />5 REBAR AT <br />BOTTOM OF <br />= W I j <br />2 z <br />O <br />LINTEL CAVITY <br />a F <br />V 0 U) w <br />Q <br />OTTOM <br />Ww <br />O x d O Z <br />_ <br />REINFORCING <br />Q ¢ 3 I Z <br />w <br />- <br />7-5/8"ACTUAL <br />PROVIDED IN <br />Z w ,ra <br />8" NOMINAL WIDTH <br />LINTEL <br />a =' C3 3 <br />#5 REBAR AT BOTTO <br />(VARIES) <br />U) m ¢ 00 <br />AS INDICATED <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />O O <br />4'-6" LL 4'-6" LL <br />O <br />6-10" LL <br />LINTEL PLAN - ELEV-Al <br />SCALE: %4"=1'-0" <br />+lam <br />00 <br />�® <br />c <br />cc <br />d-a' <br />CL <br />T W' <br />o -15 c� <br />C <br />c go t� C, <br />m <br />.: Ica <br />' V) C.4 t <br />CL <br />c <br />d <br />4�XXV11k@ Zoe <br />w r�» p <br />? CEcli <br />O Q <br />e +, <br />`riL a� •.�a s�• <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and spedfications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />An Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 <br />W It E <br />a) L0 <br />Q °000 In - t, <br />n <br />dii !n N <br />C) <br />Q C U. <br />J W <br />M0u a <br />Z cc Ne7 <br />_ <br />O S <br />TM <br />y O <br />r6N(O <br />Z ,°n0 N Z Q J <br />ILW��°'°' Co <br />C <br />Z N <br />W ❑ ❑ <br />N th <br />0 <br />Z <br />� o <br />Q � <br />C� <br />m <br />r„O <br />o <br />a-J cn <br />m <br />O - � <br />Cr <br />w <br />�N <br />('6 <br />F- - E <br />map 11J � <br />m <br />I <br />UI,. <br />t <br />= s <br />= <br />N O <br />_1- <br />Cl) <br />J <br />ti <br />w <br />Z <br />Cl) <br />O <br />G <br />E <br />w <br />Z. <br />�o <br />}Ms <br />a <br />a o <br />E V <br />wLL <br />Z® <br />oa <br />� E <br />c3 <br />Z <br />co fa <br /><¢ <br />Q0 <br />g <br />wz <br />-Z <br />:, <br />= L <br />(o <br />CO C <br />V <br />�5a <br />W, <br />u <br />pr <br />Zm <br />C <br />cu <br />UZ <br />m <br /><0 <br />Q W <br />�Z <br />go <br />W <br />(n <br />T <br />m <br />oa <br />LL <br /><2 <br />a <br />N W <br />1k <br />�E <br />=3 <br />o <br />w< <br />o <br />v <br />zI< <br />0; <br />: <br />E2 <br />U) <br />LOca <br />m <br /><0 <br />L0 <br />:3 CO <br />M <br />C)U <br />r" <br />Y �) <br />° <br />N <br />m <br />m N <br />r <br />U) <br />< <br />co <br />O - <br />N <br />C:)V <br />cO/ <br />T <br />L- N <br />TT <br />' O <br />LIDT <br />�. <br />< <br />E�' <br />z <br />ccU <br />z <br />E N <br />_ <br />m <br />a <br />E o a m <br />U Q p <br />=i <br />a <br />JOB <br />NO: 23-00519 <br />SCALE : AS NOTED <br />SHEET NO. <br />8 <br />