My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6275 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6275 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 1:59:05 PM
Creation date
2/28/2025 11:09:06 AM
Metadata
Fields
Template:
Building Plans
Street #
6275
Location
Back Forty Lp
Contractor
Lennar Home
Building Plans - Permit #
5934
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 1111.. _I__ _ 11 I I 1..I ] -. 1. __— .I _ <br />d 1 1'll,Tl"L r��g, 1=1 1'1_='A I. ' I 11 i I I I I I <br />ELEV AT 8'• <br />T.O.M. <br />ELEV AT 0'. <br />1ST FLOOF <br />SHINGLE Rc <br />ELEV AT 8'-0" <br />T.O.M. <br />5/8" STUCC, <br />OVER CMU <br />ELEV AT 0'-0" <br />1ST FLOOR FF <br />ELEV AT 8'-0" _ <br />T.O.M. <br />FRONT ELEVATION B <br />1 /4" = 1'-0" <br />REAR ELEVATION B <br />�J 1 /4" = 1'-0" <br />SHINGLE ROOF <br />1 1/4" THK x 6" <br />STUCCO BAND <br />5/8" STUCCO <br />OVER CMU <br />75/8" STUCCO <br />OVER CMU <br />00 <br />1 <br />2'-O" `O <br />Ah ELEV AT 0'-0" <br />1ST FLOOR FF — — —�— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />A5 <br />RIGHT ELEVATION B <br />1 /4" = 1'-0" <br />it i■1��■■■1��■■■1��■■■1��■■■1��■■■1��■■■1��■■■1��■■■1��■■■1��■■■1��■■■���■■■1��■■■1��■■■1��■■■1��■■■1��■■■1��■■■1��■■■1��■■■1��■■■1��■■ <br />_..rri� rrmrrrmmrm�rmnrmarm�rmNrrm�rm�rm��rmarmarmmrmnr�m�rm��rmmrmnrrmrrrmrrrrmmrm� <br />75/8" STUCCO <br />OVER CMU <br />ELEV AT V-0" <br />1ST FLOOR FF <br />LEFT ELEVATION B <br />1 /411 = 1'-0" <br />I <br />7 <br />A5 I <br />I <br />I <br />I <br />I <br />I <br />I <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />Ml,klrjWMWI��� <br />FINISH <br />LEVATION <br />SHEATHING <br />FACTURED <br />TRUSS <br />,RIP EDGE <br />INUM WRAP <br />INUM SOFFIT <br />ROOF FINISH PER <br />ELEVATION <br />ROOF SHEATHING <br />b` <br />MANUFACTURED <br />ROOF TRUSS <br />METAL DRIP EDGE <br />2X4 SUB -FASCIA <br />ALUMINIUM WRAP <br />PER ELEVATION <br />ALUMINUM <br />NOTE: REFER TO STRUCTURAL SOFFIT <br />SOFFIT <br />DETAIL SF01 SHEET SS FOR SOFFIT <br />ATTACHMENT DETAIL <br />OVERHANG DETAIL <br />6 <br />:-7;NCMU COLUMN DETAIL <br />FLASHING NOTES: <br />DUE TO CLARITY NOT ALL REQUIRED FLASHING ARE <br />INDICATED ON DRAWINGS. REFER TO FBC RES 2020 (7TH <br />EDITION), SECTION R703.4. AND R903.2 APPROVED <br />CORROSION -RESISTIVE FLASHING SHALL BE PROVIDED AT <br />ALL ROOFING SYSTEM INTERRUPTIONS, TERMINATIONS, <br />INTERSECTIONS, AND PENETRATIONS AND IN THE <br />EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO <br />PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR <br />PENETRATION OF WATER TO THE BUILDING STRUCTURAL <br />FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND <br />SHALL BE INSTALLED TO PREVENT WATER FROM <br />REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED <br />CORROSION -RESISTANT FLASHING SHALL BE INSTALLED <br />AT ALL OF THE FOLLOWING LOCATIONS: <br />1. AT TOP OF ALL EXTERIOR WINDOW AND DOOR <br />OPENINGS IN SUCH A MANNER AS TO BE LEAK PROOF, <br />EXCEPT THAT SELF -FLASHING WINDOWS HAVING A <br />CONTINUOUS LAP OF NOT LESS THAN 1-1/8 INCHES (28 <br />MM) OVER THE SHEATHING MATERIAL AROUND THE <br />PERIMETER OF THE OPENING, INCLUDING CORNERS, DO <br />NOT REQUIRE ADDITIONAL FLASHING; JAMB FLASHING <br />MAY ALSO BE OMITTED WHEN SPECIFICALLY APPROVED <br />BY THE BUILDING OFFICIAL. <br />2. AT THE INTERSECTION OF CHIMNEYS OR OTHER <br />MASONRY CONSTRUCTION WITH FRAME OR STUCCO <br />WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS. <br />3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR <br />METAL COPINGS AND SILLS. <br />4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD <br />TRIM. <br />5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS <br />ATTACH TO A WALL OR FLOOR ASSEMBLY OF <br />WOOD -FRAME CONSTRUCTION. <br />6. AT WALL AND ROOF INTERSECTIONS. <br />7. AT BUILT-IN GUTTERS. <br />8. WHENEVER THERE IS A CHANGE IN ROOF SLOPE OR <br />DIRECTION, <br />9. AT ROOF CRICKET OR SADDLE. <br />10. AROUND ROOF OPENINGS. <br />WINDOW NOTE: <br />ALL NEW WINDOWS MUST MEET A MINIMUM 'U'-VALUE OF <br />0.4 OR LESS AND A'SHGC' OF 0.25 OR LESS. (UTILIZING <br />THE PRESCRIPTIVE METHOD FOR EXISTING STRUCTURES) <br />* EGRESS NOTE: <br />EACH BEDROOM MUST HAVE ONE WINDOW THAT <br />COMPLIES WITH EGRESS CODES, IF THERE IS NO ACCESS <br />TO EXTERIOR THROUGH A DOOR. THE WINDOW MUST <br />HAVE A MAXIMUM SILL HEIGHT OF 44" ABOVE FINISH <br />FLOOR LINE OF THAT PARTICULAR ROOM <br />SHINGLE / UNDERLAYMENT NOTE: <br />ASPHALT SHINGLES ARE IN ACCORDANCE WITH TABLE <br />R905.2.6.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />SHINGLE UNDERLAYMENT SHALL COMPLY WITH SECTION <br />905.1.1, FBC 7TH EDITION (2020) - RESIDENTIAL <br />GENERAL FINISH NOTES: <br />APPLICATION OF STUCCO (EXTERIOR PLASTER) <br />MUST BE IN ACCORDANCE WITH FBC R703.7, <br />ASTM C926 AND C1063 <br />ALL LATH AND LATH ATTACHMENTS TO BE OUT OF <br />CORROSION -RESISTANT MATERIAL. (REFER TO SHEET SN1 <br />FOR THE ENGINEERED METHOD FOR LATH ATTACHMENT) <br />GENERAL FLASHING NOTES: <br />INSTALL FLASHING IN ACCORDANCE WITH FBC RES 7TH <br />EDITION (2020), SECTION R703.4 AND IN ACCORDANCE <br />WITH STANDARD APPLICATIONS ILLUSTRATED IN THE <br />ARCHITECTURAL SHEET METAL MANUAL (LATEST <br />EDITION) AS PUBLISHED BY THE SHEET METAL AND AIR <br />CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION, <br />INC. <br />NOTE: <br />FOAM TO BE USED ONLY WHEN MAR 2 5 Zola <br />REQUIRED BY COMMUNITY <br />SPECS. IF NOT, DETAIL TO BE <br />BUILT W/ STUCCO <br />Virtual Review Assist. c. <br />Plans Review completed and lap ved <br />for compliance with the 2020 FBC 7th Edition <br />ri <br />Anne Klahr PX23G0 <br />• , ft�/�Tillsi <br />5/8" STUCCO <br />FINISH ---- <br />2" <br />VARIES <br />ASSUMED GRADE <br />9 ELEVATION DETAIL <br />if <br />1 1/4" THICK <br />Ll <br />N <br />N <br />O <br />N <br />N <br />3 <br />Ln <br />00 <br />f4• l ._ <br />14 ^°' <br />e.. <br />"` <br />to <br />f <br />M <br />0 <br />W <br />p <br />z <br />Q <br />V) <br />(D O LO F <br />"0N <br />W L u <br />p cf) ;o m <br />N <br />U ua <br />E M <br />O = <br />v= 8 c Q <br />C)) NINE2 <br />�V! <br />w a_ <br />V � <br />W <br />^ y <br />O 00 <br />LU <br />W <br />�LjC o <br />< �W Flxm-j mgcz~ w <br />� �Ix-_OD�.Uo0 <br />OU <br />zE 00000z <br />ozmm <br />< <br />z�2anX <br />(n O <br />Z <br />Q; Q<WQO_WZ6 <br />00Q <br />ILL <br />oQ o 0 oy9LUfl <br />LL �Q� <br />0 <br />Z <br />LNLJ <br />O� <br />f�F_:MO <br />Q U) M � <br />� U5 <br />rZ <br />F- a Lo <br />cM <br />Z V <br />Wz <br />W <br />_j0 <br />0 <br />A <br />N <br />li! <br />O <br />N <br />N <br />N <br />N <br />M <br />N <br />N <br />O <br />\ <br />N <br />Z <br />0 <br />N <br />`� <br />L0 <br />Liz <br />; <br />N <br />M <br />�t <br />00 <br />ZZ <br />Qz <br />O <br />+� <br />W <br />zw <br />CY) <br />0 <br />v <br />000 <br />(_)Oco <br />Lo <br />O <br />0r0 <br />0 <br />Z <br />airy <br />¢~O <br />= <br />w =¢ <br />f- <br />T"'� <br />(Y <br />Z O = <br />W <br />a23:2 <br />�22 <br />O <br />zo <br />U <br />LL <br />gZLL <br />Z <br />az <br />U0 <br />Z <br />F� <br />0 <br />m <br />z <br />z <br />w <br />C) <br />W <br />N <br />N <br />N <br />O <br />0 <br />LAST PLOT DATE <br />O <br />" <br />z <br />• . <br />0 <br />December 14, 2022 <br />J <br />EXTERIOR <br />ELEVATIONS B <br />
The URL can be used to link to this page
Your browser does not support the video tag.