My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6275 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6275 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 1:59:05 PM
Creation date
2/28/2025 11:09:06 AM
Metadata
Fields
Template:
Building Plans
Street #
6275
Location
Back Forty Lp
Contractor
Lennar Home
Building Plans - Permit #
5934
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A/C <br />DICONNECT <br />PORCH <br />I <br />I <br />EN - <br />EEL <br />01 <br />DOI <br />L— — — — — — <br />ELECTRICAL PLAN (ELEVATIONS A & B <br />1 /4„ = 1'-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION, <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />10 #15 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />10 #12 copper to 20 amp ckts <br />10 #10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />0 <br />. 200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />I <br />VR <br />Virtual Review Assi,'N Z 5 20 <br />Plans Review completed and approved <br />for compliance with the 2020 FBC 7th Edition <br />by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />io <br />r- <br />SWITCH ° <br />4 1/2" <br />DOOR JAMB DUPLEX <br />OUTLET ih <br />TRIM - <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />ISC_'SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43 ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT IHORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />® STRUCTURED WIRE OUTLET <br />-�-- SWITCH AT 36" <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-O PUSH BUTTON FOR GARAGE DOOR OPENER <br />--0 DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />{} CLG MNT LT FIXTURE <br />-�- CLG MNT PREWIRE - FIXTURE BY OWNER <br />-{} SURFACE MNT FIXTURE <br />} WALL MNT FIXTURE <br />NOTE: <br />03 40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />,04 50W PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />06 50W MR16 4" LOW VOLTAGE OWNER <br />80 50W PAR20 NFL 4" MINI ROUND RECESS <br />00 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-0 CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />Cos COMBINATION <br />DETECTOR <br />C SMOKE DETECTOR <br />CU-182 UNDER CABINET 18" <br />-S-182 SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />— U-36 = UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />® 48"CLG MNT WRAPPED FLUOR LIGHT <br />9724:R 24" VANITY LIGHTING <br />9;;—m 36 :;;R 36" VANITY LIGHTING <br />4848" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />CM CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />11&3 ELEC PANEL <br />® VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />ED A/C REGISTER <br />THERMOSTAT <br />On SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />U1 4) N L E <br />o 0 <br />W L.s <br />�} �M0 <br />to V -0 m <br />/- M <br />� o <br />[ W 2 S <br />.1'. pLL8 0 ¢ <br />U � <br />._ p� <br />V) V w aN <br />N L o E� <br />.9) <br />V, <br />W U� W <br />LLj 2w p F- <br />�02�¢O¢o:¢LLUO0_j0 <br />C='J(n�W 0O00mZ <br />zZ ¢J <br />a. 55www¢OZQ <br />0w�zw <br />aU.aa <br />LL <br />w �9 <br />¢ <br />O=0Q O LL <br />U. <br />R <br />O <br />Z W <br />O� <br />U ti <br />C]�MO <br />Q to M U-) <br />Ln <br />F- Ct CL e) <br />QUa00 <br />Z <br />W <br />W <br />_� <br />O <br />J <br />d' <br />N <br />O <br />N <br />N <br />N <br />N <br />N <br />N <br />O <br />a <br />O <br />r <br />CDI <br />' <br />Z <br />O <br />N� <br />i <br />I <br />LO <br />� <br />� <br />N <br />M <br />zZ <br />¢z <br />O <br />W <br />zw <br />000_ <br />O <br />UU U <br />i.i <br />O <br />Oro <br />� <br />Z <br />a -a <br />Q <br />= <br />W <br />m~OF- <br />T -'I <br />ZO= <br />■ ■ <br />W <br />O <br />Q�� <br />2gm <br />zwo <br />Z <br />V <br />gZLL <br />u_ <br />� <br />Z <br />�z <br />pV <br />a. <br />_o <br />W <br />z <br />z <br />z <br />w <br />W <br />J <br />N <br />Co <br />" <br />O <br />LAST PLOT DATE <br />o <br />Z <br />. . <br />0 <br />December 14, 2022 <br />J <br />ELECTRICAL PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.