My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36523-36537 Camp Fire Ter
Zephyrhills
>
Building Department
>
Building Plans
>
36523-36537 Camp Fire Ter
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:49:31 AM
Creation date
2/19/2025 10:20:42 AM
Metadata
Fields
Template:
Building Plans
Street #
36523-36537
Location
Camp Fire Ter
Contractor
Lennar Home
Building Plans - Permit #
6089-60921
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />3 THREE-WAY SWITCH <br />14 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED LIGHT FIXTURE <br />P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />P� PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />© 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />�]M ELECTRIC METER <br />ELECTRIC PANEL <br />i DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />A9 (1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I I <br />I I <br />I I <br />� I <br />LAV 1\ <br />-1 1 <br />L TUB/ <br />WIC SHOWER <br />3" VTR <br />�L <br />I <br />I <br />I <br />I <br />I <br />I OPT. <br />LAV <br />LAV <br />I <br />ti W/C <br />SHOWER <br />— <br />STU DOR <br />VENTTI , DBL SINK <br />T' W/ DISP. <br />W/C <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />UNIT -A 1532 (1532) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1533 S.F. <br />4599 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10599 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8600 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHERLOAD WATTS <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33659 <br />1st 10 KW at 1 <br />1 00 <br />BALANCE OF WATTS AT 40% <br />9464 <br />AIR CONDITIONER WATTS AT 100% <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />1 5200 <br />TOTAL: 31768 <br />LOAD WATTS -- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Riser Diagram <br />4 UNIT BUILDING <br />(2) 1532 UNITS & (2) 1624 UNITS <br />c1 <br />800 AMP <br />0TENANT <br />TERMINAL BOX <br />O <br />PANEL w/ 150 <br />150 AMP <br />150 AMP <br />AMP INSIDE MAIN <br />O <br />O <br />150 AMP <br />150 AMP <br />0O <br />1P <br />150 AMP <br />GROUND <br />1/0 CU. TO BUILDING STEEL <br />C.O. <br />2" PVC CONDUIT WITH 2 #2/0 AL - 1 #1/-0 AL-1 #1 AL <br />TO POWER CO. 6 REQUIRED PER BUILDING <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 -17 LOCAL CODES AND THE LOCAL POWER CO. <br />OUTDOOR LIVING <br />INSTALL LIGHT <\ J, /i> <br />ROUGH -IN <br />FOR OPT. <br />FAN/LIGHT WP <br />' GFI <br />QDGFI <br />I jG <br />I� <br />DINING <br />KITCHEN <br />l <br />GFI <br />SWITCH FOR <br />DISPOSAL IN CAB <br />UNDER SINK <br />1491 <br />GREAT ROOM <br />/,>ROUGH -IN\ <br />FOR OPT. <br />FAN/LIGHT <br />y� � <br />I <br />I <br />FOYER <br />�i <br />I I <br />I <br />I DB <br />ENtRY P Wo- <br />LIGHT AS b FI& <br />PER SPECS <br />DB & GFI TO <br />----------- <br />BE ALIGNED <br />VERTICALLY <br />I <br />I <br />I <br />I <br />I <br />1 UPSTAIRS C <br />GFI <br />@ 44" <br />` \ <br />W.H. <br />A.F.F. <br />1 \ 0 <br />GARAGE <br />I <br />\ GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />DOOR <br />GFI <br />--------------- <br />I <br />I _ <br />bz <br />I <br />I <br />Fa <br />1 <br />�a <br />I <br />W <br />I <br />I <br />Dw <br />I <br />I <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />DISCONNECT <br />1ST ELECTRICAL - UNIT -A 1532 <br />SCALE: A"=1'-0" <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />NOTE: <br />-INSTALL 2" CONDUIT TO METER CAN <br />-INSTALL A MAIN 150 AMP BREAKER IN PANEL <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />2ND ELECTRICAL - UNIT -A 1532 <br />SCALE: A"=V-0" <br />s•� <br />ca <br />CM <br />rs ' <br />cr 47 � cn <br />a c <br />N <br />O <br />CV <br />`��t6iitla`�A <br />t <br />d �� •No Pt- <br />O • STATE <br />a <br />•r .� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Cade - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />E <br />Q o 8 0 <br />U <br />G ��0D U <br />W my LL <br />LL W <br />J LL _W LL <br />W. <br />13 <br />Z 'ac °f <br />jw <br />e&zD ?� <br />00 <br />W <br />Z Co N <br />aIL IL J <br />«) Z <br />Z N OU v <br />W pp <br />(D Ih <br />z � g <br />z <br />Z � <br />fl- <br />- N <br />l� <br />N zCM <br />v�o <br />t'6 W <br />O <br />U) mf (�V <br />U <br />t 8 <br />z�«- <br />I <br />_ � m <br />_' <br />Of <br />Q o <br />• <br />sr <br />o <br />co <br />M <br />z <br />m9 <br />w <br />Z <br />Z <br />Q <br />a E <br />ujKo <br />z <br />oa <br />K O <br />0 OU <br />Z <br />N <br />i <br />�¢ <br />¢o <br />ao <br />O¢ <br />ww <br />Z <br />d <br />M <br />C <br />z a <br />QY <br />m0 <br />O <br />ZLL <br />'¢w <br />ZZ <br />¢ <br />O <br />�° <br />U <br />a <br />W <br />Q S <br />m w <br />o <br />o <br />MI5 <br />� <br />8. <br />R <br />Z ¢ <br />a1 <br />o- <br />U <br />C O <br />�L6 <br />_ <br />al <br />d- <br />0 <br />T <br />M <br />CU <br />� CD <br />O <br />N <br />CN <br />00 <br />m <br />N <br />0 N <br />04 <br />LO <br />O <br />LC) <br />F-� <br />C <br />'(� N <br />Q <br />Cn <br />LIi7 <br />O T <br />T <br />r <br />O <br />M <br />Z <br />Go <br />E O to <br />r0 <br />m <br />a. <br />E <br />0 -1 ¢ o <br />°i <br />JOB <br />NO: 22-11668-11666 <br />SCALE : AS NOTED <br />SHEET NO. <br />13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.