My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36523-36537 Camp Fire Ter
Zephyrhills
>
Building Department
>
Building Plans
>
36523-36537 Camp Fire Ter
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:49:31 AM
Creation date
2/19/2025 10:20:42 AM
Metadata
Fields
Template:
Building Plans
Street #
36523-36537
Location
Camp Fire Ter
Contractor
Lennar Home
Building Plans - Permit #
6089-60921
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-- - _ 1u ° i ° I- --_L <br />Ill. .. .I .' 14 1 1] <br />MIRROR <br />OWNER'S BATHROOM <br />SCALE: 3/8" =1'-0" <br />BATHROOM 2 <br />SCALE: 3/8" = V-0" <br />4 <br />f, <br />STAIR DATA: <br />18 RISERS @ 7.153" <br />17 TREADS @ 10" <br />TOTAL RISE = 10'-8 3/4" <br />TOTAL RUN = 14'-2" 42" KNEE WALL <br />WITH 1x8 CAP & <br />3/4" PLYWOOD �� CASING (AT 2nd <br />DECKING �� FLOOR ONLY) <br />c7 <br />F. FL. <br />------- - - - - - - - - - - -- <br />v 18 <br />U U 17 <br />16 <br />15 <br />14 <br />13 <br />12 <br />11 CONT. <br />10 LHAND RAIL <br />EM <br />io <br />F. FL. <br />2x STRINGERS <br />TYP. STAIR SECTION <br />SCALE: 1/4" = V-0" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1 /2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) -1 3/4" X 91/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2)- 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />184X251 <br />S.H. <br />13 <br />20X38J <br />18JX37J <br />S.H. <br />14 <br />20X501 <br />184X50 <br />S.H. <br />15 <br />20X63 <br />18JX62J <br />S.H. <br />16 <br />20X72 <br />18JX71J <br />S.H. <br />11-12 <br />271/4X26 <br />26X25} <br />S.H. <br />11-13 <br />271/4X38J <br />26x371 <br />S.H. <br />1 H4 <br />27 J X 501 <br />26 x 50 <br />S.H. <br />1H5 <br />27JX63 <br />26X621/2 <br />S.H. <br />1116 <br />27JX72 <br />26X711/2 <br />S.H. <br />22 <br />37 J X 26 <br />36 J X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 1 <br />36 } X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 } X 62 1/2 <br />S.H. <br />26 <br />37JX72 <br />36}X711/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />734 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 4 <br />S.H. <br />33 <br />54 X 38 J <br />52 } X 37 J <br />S.H. <br />34 <br />54 X 50 J <br />52 J X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62 4 <br />S.H. <br />36 <br />54 X 72 <br />52 } X 714 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />(2) 2X8 w/ 1/2" <br />FLITCH HEADER <br />SLOPE CEILING TO <br />MATCH STAIR RISE <br />F. FL. <br />e <br />DRYWALL <br />1 1/2" MIN. CLEARANCE <br />1 1/4" TO 2" DIA <br />HANDRAIL NO <br />LESS THAN 34' <br />NOR MORE <br />THAN 38" ABV. <br />TREAD NOSING <br />METAL <br />HANDRAIL <br />BRACKET <br />BLOCKING AS <br />REQUIRED <br />S <br />S <br />C <br />J <br />F. FL. <br />HANDRAIL DETAIL <br />2x4 #2 SYP. P.T. THRUST SCALE: 3" =T-0" <br />BLOCK W/(2)-1/4"x 31/2" <br />TAPCONS @ 16"o.c. AND <br />3" FROM EA. END. <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 318 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the Gear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding 1/2 inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />18'-4" <br />AI All 4n' All <br />VERIFY <br />AC PAD LOCATION OF <br />A/C PAD <br />HB <br />A <br />---------------------------�- <br />OUTDOOR LIVING <br />S3 <br />9'-4" CLG. A.F.F. <br />o <br />[8" <br />CONCRETE <br />6'-0" <br />10'-8" <br />6'-8" <br />T-10" T-10" 2'-8" <br />o� <br />~ rn <br />6068 SGID C <br />250 <br />Q °O <br />5-SH <br />l- T <br />T <br />o- <br />N <br />----- ---1 <br />`t <br />2468 REF <br />® 7'-11" <br />I <br />S-2" 6'-7" <br />1 <br />OMc <br />N <br />cn <br />3dI <br />Cl)DINING <br />KITCHEN z'0 <br />a <br />9'-4" FLAT CLG. <br />9'-4" FLAT CLG. <br />® TILE <br />TILE <br />SINKw/ I <br />D/W DISPOSAL <br />in <br />I I 1 <br />L _ J <br />FLRG. LINE <br />2x8 WALL <br />® 8'-0" <br />6'-0" 3'-8" <br />s <br />16" CNTR. AT 42"-1,ten <br />o <br />r <br />A. F. F. 1/2 WALL <br />O N <br />^ <br />CAPPED <br />1 <br />r <br />® <br />II UP 2 <br />oQ <br />fV <br />I 3 <br />M <br />55 <br />4 <br />o <br />M <br />D1 <br />GREAT ROOM 5 <br />TYP. U.N.O <br />® <br />9'-4" FLAT CLG. <br />CARPET <br />7 <br />13'-8" <br />O <br />� <br />GG t` 9 <br />® f_° <br />S3 10 <br />11 <br />o <br />O� <br />12 <br />CO <br />N <br />2x6 WALL <br />6' 8" <br />2'-8" 4'-4- <br />NO UPLIFT* _ <br />® <br />Q - <br />S4 -- - -- <br />°° w <br />iv <br />FLRG_LINE <br />H1 N 'Zr V V 1'�- <br />1 TILE <br />CV <br />N <br />N i co r u_ <br />o <br />• FOYER <br />1 <br />9'-4" FLAT CLG. <br />2868 <br />TILE <br />oo <br />~ �T.O.M <br />EDGE OF SLAB 2" 0° <br />N <br />_`t <br />BEYOND WALL W.H. <br />to <br />9-4'v <br />O <br />T-0" <br />2'-6" <br />■ © 3068 <br />BUILDER TO <br />PROVIDE <br />APPLIANCE <br />2'- 4'-0" '-0 PROTECTION <br />I <br />WHEN <br />REQUIRED PER <br />o <br />4 <br />E N Y <br />FBC <br />`o <br />`o <br />9'-4" PLG. A.F.F. m <br />1-CAR ARAG E <br />CONCRETE <br />----- -- <br />- 9'-4"F TCLG. <br />q <br />®03 rn <br />CONCRETE <br />■ - <br />;o <br />■ o <br />� <br />STONE <br />boo <br />N <br />VENEER <br />~ <br />16" SQUARE <br />o <br />CMU COLUMN <br />in <br />r---------- ------ <br />� <br />-o5o <br />I I <br />I I <br />I I <br />= <br />r � <br />■ I LINE OF 2nd STRY. ABV. <br />- <br />I- + - <br />�' <br />I **NOTE <br />ao p <br />I BLK. WALLS RE 8'-8" <br />TALL FOR "A" NIT 5'-8" 1 <br />o HB <br />FROM FRO T OF <br />K GARAGE <br />TYP. @ I <br />I S4 GARAGE <br />o <br />N <br />8'x7' GARAGE OR <br />1ST FL <br />SCALE: Ya'=1'-0" <br />18'-4" <br />OOR PLAN - UNIT -A 1532 <br />D1 <br />STONE <br />'-8" VENEER <br />iD <br />0 <br />0 <br />0 <br />co <br />Y <br />8� <br />FILLED CELL LEGEND <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />® FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />__ - - - - - - - - - - - - - - - -I <br />2ND FLOOR PLAN -UNIT-A 1532 <br />SCALE: X"=V-0" <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />OA <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />DE <br />+26.6 / -29.1 <br />O <br />+26.6 / -33.5 <br />GO <br />SEE SN SHEET �H SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />[SOFFIT DESIGN PRESSURE <br />+29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or class duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />2-STORY MASONRY WALL w/ <br />❑ BOND BEAM HGT. AT 10'-8" <br />TOP AT 18'-8" <br />MASONRY HGT. @ 9'-4" A.F.F. <br />MASONRY HGT. @ 8'-8" A.F.F. <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR 677 S.F. <br />2ND FLOOR 864 S.F. <br />TOTAL 1541 S.F. <br />GARAGE 246 S.F. <br />LANAI 110 S.F. <br />ENTRY 42 S.F. <br />TOTAL SQ. FT. 1939 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFLES AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />OG.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />Cn <br />CV <br />N <br />OO <br />o ,. <br />C11- <br />ti r,D <br />�c <br />E <br />U = x <br />cx y :v <br />Q <br />w 2 O <br />E <br />N <br />.a <br />N <br />Q <br />N <br />C� tJo 1=' - 875,0, <br />A-C1' <br />% <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />0 <br />W <br />E <br />g $ 8 <br />N 6o <br />v 6, <br />:? CO d N prp <br />Lo <br />G <br />in�� 2 <br />M M 0 Z255 LL <br />.4C -1 5 u- W <br />LL LL S a <br />Lu <br />Z cc C a <br />F o <br />O <br />W ' `° r- <br />p <br />W rR�jOf m <br />Z Q <br />N Z <br />N <br />Z OU <br />W 13 E] <br />C9 "' V <br />z <br />z a � <br />V <br />J <br />d � <br />n <br />to0 z W <br />W 8 <br />o <br />W <br />0 <br />�_ 8 <br />to <br />U <br />LU <br />EE <br />L 8 <br />N <br />so <br />O <br />MN <br />Cl) <br />6� <br />w <br />Z <br />a <br />a <br />uJ. <br />ca <br />zo <br />�0 <br />�i <br />s <br />>p <br />z® <br />oa <br />rQ <br />g <br />p <br />Z <br />O <br />~CD <br />oo <br />oa <br />ip <br />j <br />oz <br />OZ <br />wZ <br />N <br />i <br />wo <br />a <br />¢� <br />wf <br />Z <br />-� f0 <br />dcr) C <br />C <br />� v <br />j <br />aaz <br />ox <br />m� <br />mO <br />Oa <br />Z� <br />aw <br />�z <br />N <br />50 <br />W <br />a 3 <br />(j <br />oa <br />w LL <br />ao <br />a <br />�z <br />�k <br />O <br />C)a= <br />w <br />> O <br />v <br />0 <br />°3 <br />c C)0 <br />> L <br />m <br />d <br />N <br />� <br />T <br />M <br />CIDO <br />:3 OLO <br />N <br />'- <br />_ <br />Cr CV <br />o <br />i ) Y <br />v, o <br />O <br />00 <br />0 <br />LO <br />1-- <br />N <br />CN <br />� <br />C <br />N <br />Q1--' IRt <br />O <br />O � <br />LA-) <br />T- <br />N <br />, T <br />r <br />Z <br />Z <br />E O rn <br />m <br />a <br />E v <br />U a p <br />c <br />JOB <br />NO: 22-11668-11666 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.