Laserfiche WebLink
4 <br />STAIR DATA: <br />18 RISERS @ 7.153" <br />17 TREADS @ 10" <br />TOTAL RISE = 10'-8 3/4" <br />TOTAL RUN=14'-2" <br />3/4" PLYWOOD <br />E DECKING <br />_ F. FL. <br />F. FL. <br />OWNER'S BATHROOM <br />SCALE: 3/8" =1'-0" <br />BATHROOM 2 <br />SCALE: 3/8" = V-0" <br />18 ----- <br />17 <br />16 <br />42" KNEE WALL <br />WITH 1x8 CAP & <br />CASING (AT 2nd <br />FLOOR ONLY) <br />\ <br />\ <br />\ <br />\ <br />\ <br />\ <br />\ <br />- - - - - - - - - -- <br />13 <br />12 <br />T11 <br />2x STRINGERS <br />8 <br />4 <br />00 <br />FILLED CELL LEGEND <br />CONT. FILLED CELL FROM FOUNDATION TO 2ND <br />FLOOR <br />® FILLED CELL BELOW 2ND FLOOR (DOWEL INTO <br />LINTEL) <br />® FILLED CELL ABOVE 2ND FLOOR (DOWEL INTO <br />BOND BEAM) <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 } X 25 J <br />S.H. <br />13 <br />20 X 38 J <br />18 4 X 37 1 <br />S.H. <br />14 <br />20X501 <br />184X50 <br />S.H. <br />15 <br />20X63 <br />18JX624 <br />S.H. <br />16 <br />20X72 <br />18}X71} <br />S.H. <br />1 H2 <br />271 /4 X 26 <br />26 X 25 } <br />S.H. <br />1H3 <br />271/4X38J <br />26x37 <br />S.H. <br />1 H4 <br />27 J X 50 J <br />26 x 50 <br />S.H. <br />1 H5 <br />27 4 X 63 <br />26 X 62 1/2 <br />S.H. <br />1 H6 <br />27 J X 72 <br />26 X 71 112 <br />S.H. <br />22 <br />37 J X 26 <br />36 J X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 J <br />36 } X 37 3/4 <br />S.H. <br />24 <br />37 J X 50 J <br />36 } X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 J X 62 1/2 <br />S.H. <br />26 <br />37JX72 <br />36}X711/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 J X 25 J <br />S.H. <br />33 <br />54 X 38 J <br />52 } X 37 J <br />S.H. <br />34 <br />54 X 501 <br />52 J X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62 J <br />S.H. <br />36 <br />54 X 72 <br />52 J X 714 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />(2) 2x8 w/ 1/2" <br />FLITCH HEADER <br />SLOPE CEILING TO <br />MATCH STAIR RISE <br />F. FL. <br />\ <br />CONT. <br />HAND RAIL <br />TYP. STAIR SECTION <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2' <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) -1 3/4" X 91/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) -1 3/4" X 71/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />F. FL. <br />DRYWALL <br />1 1/2" MIN. CLEARANCE <br />BLOCKING AS <br />REQUIRED <br />2x4 #2 SYP. P.T. THRUST <br />BLOCK W/(2)-1/4"x 31/2" <br />TAPCONS 3' FROM EA, El END,c. AND HANDRAIL D F TA I L <br />SCALE: 3" =V-0" <br />1 1!4" TO 2" DIA <br />HANDRAIL NO <br />LESS THAN 34" <br />NOR MORE THAN <br />38" ABV. TREAD <br />NOSING <br />METAL HANDRAIL <br />BRACKET <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the Gear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding Yz inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />C <br />r <br />13'-4" <br />AC PAD <br />VERIFY <br />LOCATION OF <br />A/C PAD <br />------------------------- <br />OUTDOOR LIVING <br />0 <br />9'-4" CLG. A.F.F. <br />o <br />Eo <br />CONCRETE <br />Eo <br />'_0" 16'-8" <br />6'-8" T-10" T-10" 2'-8" <br />�o <br />6068 SGD <br />°' ~ <br />© <br />t <br />oo O <br />H <br />----- -- <br />REF <br />BF <br />bo <br />I <br />o0 <br />8'-3" <br />T-2" <br />6'-7" <br />I <br />VX <br />YX <br />VX <br />874.0 <br />r <br />DINING N <br />KITCHEN w , O <br />N <br />9'-4" FLAT CLG. <br />9'-4" FLAT CLG. z <br />TILE <br />TILE < I <br />I <br />;o <br />I <br />SINK w! I <br />ao <br />to <br />D/W DISPOSAL I <br />F---I <br />I <br />I---J <br />I IE10 <br />L___J I <br />FLRG. LINE <br />-------- - <br />2x8 WALL <br />8'-4" <br />6'-0" T-8" <br />16" CNTR. AT 42" 4 <br />LO <br />' <br />En <br />A.F.F. <br />1/2 WALL <br />CD <br />Eo <br />CAPPEDEO <br />r 1 <br />- <br />r <br />I UP 2 <br />00 <br />N <br />I <br />M <br />GREAT ROOM <br />5 <br />9'-4" FLAT CLG. <br />6 <br />CARPET <br />= <br />00 <br />14' 0" <br />�_ ,, 7 <br />°o <br />- <br />0 <br />ED <br />Eo <br />PW01 <br />;� <br />D1 <br />10 <br />= GG <br />11 <br />TYP. <br />S3 <br />12 <br />,t <br />2x6 WALL <br />T-0" 2'-8" 4'-4" <br />o <br />- <br />F <br />co <br />_ _ _ <br />00 <br />fc <br />*NO UPLIFT* <br />Z_ <br />FLRG. LINE Q <br />D1 <br />CD'"y-t��yr� • <br />N ZTYP. <br />LL TILE <br />oa <br />ic' <br />FOYERN NCD <br />° <br />9'-4" FLAT CLG. 2868 <br />TILE <br />o <br />00 <br />s EDGE OF SLAB 2" <br />0° <br />in <br />CD <br />9'-4" BEYOND WALL <br />T.O.M. <br />T-4" <br />O <br />3068 <br />BUILDER TO <br />PROVIDE <br />O <br />APPLIANCE <br />= <br />PROTECTION <br />- <br />WHEN <br />:a. <br />REQUIRED PER <br />= <br />2'-0" 4'-8" <br />FBC <br />o <br />1-CAR GARAGE <br />9'-4" FLATCLG. <br />ENTRY00 CONCRETE <br />= <br />9'-4" CLG. A.F.F. o <br />= <br />CONCRETE ro <br />N <br />r--------- <br />------� <br />U) <br />2 I <br />I <br />50 <br />I <br />I <br />I <br />I <br />in <br />I <br />I <br />I <br />O I TYP. @ <br />I <br />I <br />Q <br />M <br />GARAGE <br />_ I <br />I K <br />I <br />I <br />=cq <br />. <br />I S4XB <br />I <br />00 <br />I <br />I <br />N <br />EV <br />N <br />nn <br />® e..nnnnnr <br />STONE <br />VENEER <br />1ST FLOOR PLAN - UNIT-C 1624 <br />SCALE: Y"=1'-0" <br />2ND FLOOR PLAN -UNIT-C 1624 <br />SCALE: Y4"=1'-0" <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />AO <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />O <br />+26.6 / -29.1 <br />�F <br />+26.6 / -33.5 <br />GO <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+29.7 / -39.7 <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />1■■■■■■■■■ E • - • - <br />iiiiiiiiiiiiiiiiiiiiiiiii • • <br />MASONRY PARTY WALL <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO UPLIFT <br />CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />1ST FLOOR <br />2ND FLOOR <br />664 S.F. <br />970 S.F. <br />TOTAL <br />1634 S.F. <br />GARAGE <br />246 S.F. <br />LANAI <br />108 S.F. <br />ENTRY <br />98 S.F. <br />TOTAL SQ. FT. <br />2086 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONIC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />A G.C. TO COORDINATE PLUMBING TO AVOID <br />CONFLICT WITH STRUCTURAL WD. COL. <br />o <br />t :J <br />arUJ <br />C2 -. <br />s� Z' <br />_ Cu <br />ECu <br />�, <br />�. <br />as ca <br />a� <br />z. <br />a <br />N <br />0 <br />N <br />v <br />iv0 ('t_ '�v^�• <br />r�e.�za::t'aai. <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />8 <br />a $ SE <br />0 <br />inr-tlV � ft <br />tit y- c'> uT <br />Q aL <br />a LL U. W <br />o <br />Z !a� °' a <br />v <br />�. Y�9_ O <br />7 rON� <br />Wrn <br />T m LU <br />toN Z Q J <br />ZN OU U <br />W ❑ ❑ <br />(D R <br />z � <br />Z n <br /><L G <br />cl- <br />N <br />Z fh <br />o <br />C1 <br />W u- <br />a--+ N <br />g <br />8 <br />m <br />u <br />s <br />as t 8 <br />I <br />U 19 <br />�Q <br />• <br />cn 8 <br />c <br />Q Y <br />�o <br />s <br />o <br />W <br />M <br />M <br />y <br />g <br />Z <br />� <br />J <br />� a <br />Q <br />n O <br />0 <br />we <br />� <br />ap <br />oa <br />N <br />f..._. 06 <br />N <br />uo <br />Z <br />� <br />N <br />a� <br />i <br />¢o <br />0 <br />��¢ <br />dz <br />�� <br />�no <br />CY <br /><�mo <br />Z� <br />zZ <br />� <br />gLL <br />Z <br />ao <br />Q� <br />�w <br />W <br />o� <br />oa <br />-o <br />� <br />zla <br />a <br />0 3 <br />.2 <br />>6 <br />L_ <br />m <br />T <br />CID <br />O <br />M <br />� O <br />N <br />Cr CV <br />I- <br />CDLO <br />CD <br />LC) <br />IF- <br />CV <br />o <br />Io <br />O <br />IC <br />'� N <br />Q It <br />lLn <br />O � <br />T <br />W <br />E <br />' T <br />r'_ T <br />cIRt <br />Z <br />ca <br />Z <br />E O y <br />2 <br />c`o <br />m <br />E m <br />c <br />c <br />0 <br />U J Q 0 <br />J <br />JOB <br />NO : 22-11668-11666 <br />SCALE : AS NOTED <br />SHEET NO. <br />5 <br />