My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3767 Correia Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3767 Correia Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:11:38 AM
Creation date
2/19/2025 10:21:30 AM
Metadata
Fields
Template:
Building Plans
Street #
3767
Location
Correia Dr
Contractor
Carr Contracting
Building Plans - Permit #
1204
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Square D "Easy deter Pack` (or equal). <br />120/200V 3i 4 Win SN in and <br />120/208V 30 4 Wire SN out to Suites. <br />�a 100 <br />100 <br />cal <br />In Fused <br />connect <br />120/208v 3e <br />UNNuty Xfmr. <br />2 SetsAluminum <br />ea. (4)l <br />2 CU <br />Extend towater line <br />and twNdk�q _steel M accordance <br />with NEC 250 <br />bYl 1 � <br />Panel L7 <br />Panel L2 <br />POW L3 <br />Suite 101 <br />Suite 102 <br />Suite 103 <br />100A MLO <br />100A MLO <br />100A MLO <br />120/208Y <br />120/206V <br />I I <br />120/2Z <br />I <br />Wire <br />3f Wine <br />3/ NAn <br />(3)6,8N.IMI "C <br />SN <br />S <br />SN <br />Steel F bar min. <br />per <br />NEC 250.50 <br />irNnimum (2)5/8-i Copper Clad <br />Ground Rods spaced 10 apart. <br />ELECTRICAL LOAD CALCULATIONS: <br />BUILDING SERVICE <br />EXTERIOR BUILDING LIGHTS KW <br />Exterior Building Lights .24 <br />.24 <br />Continuous Load - 0.24 X 1.25 = .30 <br />Sub Total 0.30 <br />RECEPTACLES Est. (4) O 180 - 0.72 <br />Sub Total 0.72 <br />SUITES tot THRU 107 <br />7 Sultse x 12.74 - 89.18 <br />Sub Total 89.18 <br />MISCELLANEOUS <br />Building Signage 1.50 <br />Future Equipment 5.00 <br />Tom 96.70 <br />96.70 KW O 120/208V 30 4 Wfn SN - 268 Amps. <br />Service - 400A 120/208V 3/ 4 We SN <br />RR � S E R D � A G` � 'N"A M. <br />Po49 <br />ELECTRICAL LOAD CALCULATIONS: <br />TYPICAL SUfTES 1 THRU 7 <br />LIGHTING <br />KW <br />1238 Sq. Ft. Warehouse 0 .95 watts per - 1.18 <br />359 Sq. Ft. Offlas O 1.11 watts per - <br />0.40 <br />53 Sq. Restmom O .98 watts per - <br />0.05 <br />Table C405.4.2(2) FBC Energy conservation 1.63 <br />Continuous Load 1.63 X 1.25 = <br />2.04 <br />Sub Total 2.04 <br />RECEPTACLES <br />2.48 <br />Sub Total 2.48 <br />NVAC <br />(1) HP O 2330 = <br />2.33 <br />(1) AH 0 458 - <br />0.46 <br />Sub Total 2-79 <br />MISCELLANEOUS <br />(1) Warehouse Fan 0528 - .53 <br />1 Water Heater 3.40 <br />1 Sign O 1500 - 1.50 <br />al 12.74 <br />12.74 KW O 120/2011V 3e 4 Wire SN - 35 Amps. <br />Service - t00A 120/200V 30 4 Wire SN <br />PANELS "Lt THRU L7' SCHEDULE 10.000 AIC <br />SERVES <br />LOAD <br />B/P <br />CKT <br />B/P <br />LOAD <br />SERVES <br />Spare <br />20/1 <br />1 <br />2 <br />30 1 <br />3400 <br />Water Heater # <br />Office/Lobby Lights <br />355 <br />20/1 <br />20/1 <br />3 <br />5 <br />4 <br />6 <br />20/1 <br />20/1 <br />1500 <br />720 <br />Siig�n <br />ORke Receptacles <br />Warehouse Lights <br />782 <br />Space <br />9 <br />10 <br />20/1 <br />860 <br />Worshs/DF Recept. <br />11 <br />12 <br />20/1 <br />360 <br />Lobby Recept. <br />13 <br />14 <br />Sr <br />Wa ouse Fan <br />528 <br />15/1 <br />15 <br />16 <br />Six ice <br />17 <br />18 <br />20/1 <br />540 <br />Warehouse Receptacles <br />19 <br />20 <br />Space <br />21 <br />22 <br />HPI <br />1165 <br />223 <br />I/2 <br />24 <br />1165 <br />25 <br />26 <br />AHI <br />230 <br />15/2 <br />27 <br />28 <br />230 <br />U <br />30 <br />Sub -Total 1165 1113 2177 3400 2360 1820 <br />Total 4565 3473 3797 121119 Demand Phase) Phase) <br />- - 38 Amps Hi(gheste <br />Notes: 100A MLO 120/208V 30 4W SN <br />k - Lockable Breaker <br />-_- PANEL 'HP" SCHEDULE 10,000 AIC <br />SERVES <br />L� <br />B/P <br />CKT <br />B/P <br />LOAD <br />SERVES <br />•A <br />Ext. Bldg. Lights <br />236 <br />20/1 <br />1 <br />2 <br />20/1 <br />Spare <br />Space <br />3 <br />4 <br />20/1 <br />1500 <br />Monument Sign <br />5 <br />6 <br />20/1 <br />900 <br />Exterior Receptacles <br />20/1 <br />re <br />I <br />�c <br />1 <br />2 <br />i <br />Sub -Total 236 1 0 0 10 115001 9001 <br />Total 236 1500 900 2536 - 13 Amps Connected (Highest Phase) <br />2695 - 14 Amps Demand (Highest Phase) <br />Notes: 60A MLO 120/208V 30 4W SN <br />(3)1,1N,40.2"C <br />(3)2.2N.80.2'C <br />(3)3.3NAU"C <br />2X SERVICE/FEEDER VOLTAGE DROP CHART <br />This drat 1s based an a 208 Amp Demand, 208V 30 Service from Utility <br />Vw. to Meter Cenbr/Owksn. Then from 100/3(0 80X) B1w. to Panel L1 <br />Suits 101(80 Amps). <br />WIRE TYPE AND SUE zm 3 <br />UTILITY XFiIdR. TO WIREWAY <br />(2) aookomr 7TC Tw/THMNV Wire (AL) - 150 1.47 .71 <br />100A CO TO PANEL Lt <br />1 75'C THW/THWN Wins - 11a 2.46 1.18 <br />VD 1.47 - 0.71X 0 20BY <br />VD 2.48 - 1.18X 0 208V <br />TOTAL VO 3.93 - I MX 0 208V <br />Chart indicates distance with lad as shown. Should total distance exceed <br />what is indicated It is to be brought to the attention of this Engineer: <br />NOTE AN win Capper unless Indicated otherwise. <br />2X SERVICE/FEEDER VOLTAGE DROP CHART <br />This chart is based on a 268 Amp Demand, 208V 3/ Service from Utility <br />Xfmr. to Meter Center/8nakere. Then from 100/3(411 80X) Bias. to Panel <br />LI Suite 103, and Panel L6, Suite 106(80 Amps eo.). <br />WIRE TYPE MID SUE fg[ YD im <br />UTILITY XFW. TO WIREWAY <br />(2) 500kcmll 75-C TNW/R MM Wire (AL) - 150 1.47 .71 <br />100A CB TO PANELS L3. AND L6 <br />3 7IrC THW/THMN Wire - 65 2.21 1.06 <br />VD 1.47 - 0.71X 0 200V <br />VD 2.21 - 1.06X 0 206V <br />TOTAL VD 3.68 - 1.77% 0 206V <br />Chart Indicates distance with lad as shown. Should total distance exceed <br />what is indicated it is to be brought to the attention of this Engineer. <br />NOTE: AN win Copper unless indicated oth enelm <br />3% EQUIPMENT VOLTAGE DROP CHART <br />This chart is bond on a 20 amp single pole <br />breakw ,120/206VV330 Service. at ma*nurn (18 amps) <br />WIRE TI AND SIZE XM <br />#12 7sC "/THWN Wire - 114 <br />#10 7SC THW/T►IMM NAre - lei <br /># 8 79C THW/THWN Wire - 288 <br />NOTE <br />Thin chart is "Worst Case". Actual length of who <br />when calculated from load to Mad and how the <br />conduits are run am vary from this chart. <br />L1-35,37 L2-35,37 <br />(2) 12,120,3/4-C (2) 12,120,3/4-C <br />SUITE A SUITE B <br />2X SERVICE/FEEDER VOLTAGE DROP CHART <br />This chart is based on a 268 Amp Demand. 20M 3e Servles from UNNbr <br />Xfmr. to Meter Center/Redeem. TMn from 100/3(O 80x) am to Panel <br />L2. Suits 102, and Panel L7. Suits 107(80 Arras so.). <br />WE TYPE ANO SUE <br />UTILITY XFLK TO WN MY <br />(2) 5001rcmN 75-C THW/111 M4 Win (AL) - 150 1.47 .71 <br />t00A CO 70 PANELS L2. AND L7 <br />2 7VC THW/'*M Wire - 90 2.42 1.17 <br />VO 1.47 - 0.71X 0 208V <br />VD 2.42 - 1.17X 0 2DOV <br />TOTAL VD 3.89 - 1.88X 0 208V <br />Chat Indicates distance with load as shown Should total distance exceed <br />what is indicated It is to be brought to the attention of thin Engineer. <br />NOTE: AN wire Copper unless Indlootnd otherwise. <br />2% SERVICEIFEEDER VOLTAGE DROP CHART <br />This chart is bond on a 208 Amp Demand 206V 3/ Seta from UtI ty <br />Xfrnr. to Meter Carta/Bnaksm. Then from 100/1 001h Bkm to Panels <br />L4, Suits 104, and L5 Suits 105(80 Amp ea.). <br />WIRE TYPE A10 SUE EM !� <br />UTILITY XFMR. TO WIREWAY <br />(2) 5001romN 7rC 11fW/THYYN Win CAL) - 150 1.47 .71 <br />100A CS TO PANELS L4, AND L5 <br />3 75C THW/THWN Wire - 50 1.70 .82 <br />VD 1.47 - 0.71X 0 208V <br />VD 1.70 - 0.82X 0 208V <br />TOTAL w 3.17 - I AM 0 208V <br />Chart kndlootse distance with load as Mown. Should total distance exceed <br />what is kndioated it is to be brought to the attention of this Engineer. <br />NOTE AM win Copper wArse I kcal otherwses. <br />SHORT CIRCUIT CALCULATIONS: <br />NEW SERVICE <br />l SC - i + 1.732(1 a0 27828 <br />2 213W 208 <br />1 Sc - 15353 5 AIC 400A Main Fused Disconnect <br />ISO - 4000.0 AIC L1 W Current 0 400A Fused disc. <br />W 400A Class T &W Fuses <br />I sc - 00000 AIC Panels L1. L2. L3. LI LI Le, L7. and NP <br />I hereby certify that I have reviewed this plan and found it to 10E in <br />compliance with ASCE 7-10 and the Florida Building Code 2017 6th Edition <br />David W, Smith, P.E. # 3608 <br />ENGINEER LICENCE #53608 <br />L3-35,37 <br />(2) 12,120,3/4-C <br />SUITE B <br />SUITE A <br />POWER PLAN <br />CHANCEY PARTNERS RICK GOLLHARDT - DRAFTSMAN <br />3761 CORREIA DR 813-781-3651 <br />ZEPHYRHILLS, FLORIDA rgollhardt@ta171,vabay.rr.com <br />D.W.SMITH,M.S.,P.E.#53608 POWER PLAN SHEET OF <br />FL❑RIDA PR❑FESSI❑NAL ENGINEER LICENSE NUMBER 53608 PROJECTS ENGINEERING CONSULTANT 4 OF 7 <br />9909 WALLASTON DRIVE-DADE CITY, FLOR I DA 33525 SCALE DATE JOB NO. <br />PHOND 813-469-2289 E-MAILI dwsf ape@earthl Ink, net DO NOT SCALE 9 OCT 2020 <br />DESIGN/DRAWN CHECKED 2020-1 003 <br />R. GOLLHARDT D.W.S.,p.e. <br />