My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38100 Fallstone Way
Zephyrhills
>
Building Department
>
Building Plans
>
38100 Fallstone Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2025 10:28:18 AM
Creation date
2/19/2025 10:21:34 AM
Metadata
Fields
Template:
Building Plans
Street #
38100
Location
Fallstone Way
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7, Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1,1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FfF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />61 <br />-!?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />I'_0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />IER <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />T� <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />t1_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />�7K - I-� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r'✓ T J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />r� I ► <br />I ► <br />I I <br />I 1 <br />LAV 1\ <br />3" VTR <br />AIL <br />I <br />I <br />I <br />I <br />I OPT <br />LAV <br />I LAV <br />I <br />I <br />I <br /><0 u W/C <br />SHOWER <br />DISCONNECT <br />O <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />L TUB/ <br />W/C SHOWER ------------------- <br />OUTDOOR LIVING � <br />II <br />STUDOR DBL SINK ` C.O. ��y �i� INSTALL LIGHT I 4 <br />VENT W/ DIISP C��1 FOR OPT. <br />LAV W/C 3" WP'�`FAN/LIGHT <br />,E,/3" GFI I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC <br />TO BE VERIFIED WITH PLUMBER <br />LOAD CALCULATIONS <br />Unit -B- (1516) <br />SQ. FT. AT 3 WATTS / SQ. F.T. <br />1505 S.F. <br />4515 <br />SMALL APPLIANCE CIRCUITS AT 1500 WATTS <br />3 <br />4500 <br />LAUNDRY CIRCUITS AT 1500 WATTS <br />1 <br />1500 <br />SUBTOTAL: 10515 <br />DISHWASHER AT 1200 WATTS <br />1 <br />1200 <br />DISPOSAL AT 960 WATTS <br />1 <br />960 <br />WATER HEATER AT 5500 WATTS <br />1 <br />5500 <br />DRYER OUTLET AT 5000 WATTS <br />1 <br />5000 <br />AIR HANDLER UNIT AT 1200 WATTS <br />1 <br />1200 <br />RANGE AT 8000 WATTS <br />1 <br />8000 <br />MICROWAVE AT 1200 WATTS <br />1 <br />1200 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />OTHER LOAD WATTS <br />0 <br />SUBTOTAL: 23060 <br />TOTAL: 33575 <br />1st 10 KW at 100% <br />10000 <br />BALANCE OF WATTS AT 40% <br />9430 <br />AIR CONDITIONER WATTS AT 100% <br />7104 <br />HEAT PUMP WATTS AT 100% <br />0 <br />HEAT PUMP & SUP. HEAT WATTS AT 65% <br />1 <br />5200 <br />TOTAL: 31734 <br />LOAD WATTS --- 240 VOLTS <br />AMPS: 133 <br />PROVIDE 150 AMP SERVICE <br />Optional Overhead Service <br />Same As Underground <br />150 Or 200 Amp Service <br />1 <br />Power Co. Feed <br />200A <br />Indoor Panel <br />Center <br />NEMA1 <br />RMAN <br />200 AMP <br />3R <br />Cable <br />#4 Solid COPPER Ground <br />Intersystem Bonding <br />Termination Per <br />NEC 08, 250.94 5/8" Galvanized Driven Ground <br />Rods at least 6' apart <br />Typical 150-200 Amp Electrical Riser Diagram <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE PROVISIONS OF <br />THE NFPA 70 - 17, LOCAL CODES AND THE LOCAL POWER CO. <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE <br />RANGE HOOD PER <br />SPECS <br />GFI <br />aF <br />DINING <br />�I 1 <br />KITCHEN <br />�I <br />L_-0FJ� oo GFI <br />- - - & GFI --- <br />SWITCH FOR <br />DISPOSAL IN CAB <br />C.M. UNDER SINK <br />II � <br />I <br />I / <br />GREAT ROOM <br />ROUGH-IN"11\� <br />CH FOR OPT. <br />' FAN/LIGHT <br />1 � ` <br />_0 �?JVITCH <br />UPSTAIRS <br />-6 <br />FI FOYER <br />GF, / <br />O / / A.F.F. <br />I <br />DB <br />GARAG E G <br />� � FI ENT <br />, � LIGHT <br />/ PER SPE <br />GARAGE <br />LIGHT AS <br />PER SPECS <br />GARAGE <br />DOOR - I <br />GFI <br />r ----------------- I <br />1 I <br />I Z Iu.l <br />I Olz \ <br />I Q lo- <br />t 016 w <br />I r'I� I- <br />I � If— W Z <br />I IW <br />1 W 1-i � F- 0 <br />1 >IW EU_ <br />>_jm / <br />COACH LIGHTS / <br />OR PREWIRE AS <br />PER SPECS <br />DB & GFI TO <br />BE ALIGNED <br />VERTICALLY <br />1ST ELECTRICAL - UNIT-B 1516 <br />SCALE: Y4"=1'-0" <br />2ND ELECTRICAL - UNIT-B 1516 <br />SCALE: Y4'=1'-0" <br />L-A <br />N _ <br />-, <br />a, a <br />Z.- W <br />LLJ <br />a o <br />® <br />u• a c� o <br />coCIA <br />d aCc <br />Q N Y <br />�+ E <br />a <br />N <br />N <br />0 <br />N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />W <br />g <br />C <br />FA <br />i» <br />�fNb J <br />LL <br />Q <br />u u w <br />d <br />+n <br />Z <br />_j <br />d <br />o <br />j co C <br />W <br />0 <br />W <br />Z <br />00 0 m w <br />(%Z J <br />�^ <br />N <br />OU v O <br />Z <br />W <br />v <br />�M� <br />Z N ipQh <br />z o da <br />J <br />Cl- <br />0 <br />ft5 <br />W <br />� <br />U <br />0 <br />Ln <br />W s <br />�V) <br />RS <br />�- <br />wig <br />U <br />W � <br />c S <br />o <br />w <br />m <br />M <br />Z <br />o <br />Z <br />J <br />LL <br />c. E <br />E <br />zo <br />a'0 <br />F <br />� <br />�N <br /><R <br />Z® <br />O a <br />I-- <br />x' <br />U <br />nF <br />p V <br />OQ <br />N <br />L <br />ao <br />¢o <br />Ww <br />Y> <br />nm <br />mF <br />QW <br />�W <br />o <br />zZ <br />565 <br />C <br />O. <br />U <br />ao <br />0. <br />wW <br />FK <br />'S <br />o� <br />�3 <br />= <br />o� <br />o� <br />g r <br />.y <br />d' <br />iu <br />N <br />t9 <br />N <br />T— <br />�_ <br />E <br />(Li <br />T <br />CD <br />C <br />cV <br />o <br />C m <br />o <br />E <br />Ii <br />T <br />CV <br />Nv <br />c <br />Lo <br />00 CD <br />O <br />D <br />(6 et <br />M <br />Q <br />N T <br />LC) <br />00 <br />co <br />po r <br />r <br />E <br />0 <br />M r— <br />6i <br />0 <br />cc <br />Z <br />E O <br />cc <br />a.0 <br />o <br />� <br />a «? <br />Q <br />c <br />JOB <br />NO: 22-11681-11674 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.