My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
39994 Harmon Grove Ct
Zephyrhills
>
Building Department
>
Building Plans
>
39994 Harmon Grove Ct
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 8:45:07 AM
Creation date
2/19/2025 10:26:29 AM
Metadata
Fields
Template:
Building Plans
Street #
39994
Location
Harmon Grove Ct
Contractor
Lennar Home
Building Plans - Permit #
2149
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I I I' I W1*ww <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />#14 copper to lights & outlets <br />NEMA 1 #12 copper to 20 amp ckts <br />150 AMP/ <br />200AMP E 410-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />II <br />MAIN <br />V <br />0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />==r <br />UNDERGROUND <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />jCLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />j3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Q� <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />i0 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />12'-0" <br />VE IFY METER <br />LOCATION WITH <br />BUI DER H.B. <br />I <br />2° <br />2" Vf <br />PLUMBING RISER <br />SCALE: NTS <br />NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />/-1 <br />MAIN FLOOR ELECTRICAL PLAN — ELEV—B1 <br />SCALE: Y4"=1'-0" <br />CV <br />0 <br />CV <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />C> <br />H <br />Q <br />o E <br />N . <br />CD <br />0 <br />N <br />c0 00 <br />to <br />J <br />ik LL W <br />7 tti <br />Q <br />J LL LL <br />C <br />a <br />tr 0 <br />C)o <br />Z <br />tm <br />_ <br />W'mm <br />Lu <br />(V <br />ZK <br />ya <br />pLLZN � <br />cD 2 U <br />Z N M <br />o <br />Z o°Do N <br />Z r. <br />a <br />V I <br />t� <br />z <br />0 0 <br />a-1 N <br />W <br />Ua <br />O <br />W g <br />C N <br />'V) <br />v I <br />•-. <br />® <br />U � <br />W J <br />E <br />I'•,. <br />U o <br />c to 0 <br />• <br />Q N <br />o <br />Z <br />M <br />= <br />o <br />R <br />� <br />E <br />�o <br />Wa <br />Z <br /><R <br />z® <br />Q <br />o <br />E V <br />LQ <br />t� C <br />co <br />X U <br />oa <br />w¢ <br />U O <br />2 U <br />Z <br />O <br />N <br />a� <br />o <br />�� <br />aZ <br />� <br />i <br />¢o <br />� <br />mO <br />� C <br />C <br />= <br />Ox <br />Z U <br />"m <br />a <br />2 o 1- <br />Z <br />N N <br />¢w <br />gZ <br />3 <br />0 <br />no <br />W <br />C) <br />ao <br />3. <br />o <br />O <br />�_ <br />w <br />�o <br />a� <br />Mj <br />V <br />zla�o <br />3 <br />0 <br />C O <br />2 <br />41(0 <br />rn <br />c� <br />W <br />O <br />0 <br />> <br />U <br />T— <br />Q <br />0 <br />O <br />U <br />� <br />m <br />c <br />0 <br />O <br />� <br />�. <br />co <br />0 <br />= N <br />T— <br />�t O <br />CN <br />r <br />N <br />= O <br />rn <br />m <br />E <br />M d <br />o <br />Z <br />E O <br />c <br />FL <br />J <br />Q <br />c <br />J <br />JOB <br />NO: <br />21-5013 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.