ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />#14 copperto lights & outlets <br />NEMA 1 <br />150 AMP/ <br />10 #12 copper to 20 amp ckts <br />200 AMP <br />#10-2 copperto WH <br />10 #10-3 copperto Dryer <br />METER <br />MAIN <br />O0 <br />or <br />4/0 SER Alu <br />200 amp <br />150 amp <br />UNDERGROUND <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES . <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided With a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />® <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />Iwo <br />EXHAUST FAN/LIGHT COMBINATION <br />® <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />mpg <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />�-4 IL� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FO' - - <br />I I <br />L <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />r— i <br />I I <br />UPPER ELECTRICAL PLAN — ELEV—B1 <br />SCALE: Y4'=1'-0" <br />N <br />0 <br />N <br />U-) <br />o_ <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />CD <br />W <br />R <br />v E c� °�° <br />O M 8 N ik <br />_ <br />v <br />? C> c <br />W <br />U)CL <br />Mo u Jai[ <br />a�Yg0 <br />Z <br />_j <br />0 S <br />L <br />W <br />rtl <br />o o W <br />N tD R' O J <br />�°'w <br />7' <br />LLW <br />r°oo a <br />In M Z X 0 0 <br />Z <br />N L) U y <br />° U <br />❑❑❑ <br />c <br />Z N <br />z N <br />CD <br />z � � <br />J <br />(Z � <br />- N <br />M <br />z <br />o <br />(DLij <br />� <br />�N <br />Q a <br />m <br />U <br />0 <br />8 <br />cLn <br />�- rn <br />® <br />U c <br />rL J <br />I <br />=® <br />_ <br />� <br />Q <br />8 t;5 <br />c u) I <br />Q o <br />N Ol <br />o <br />W <br />Mz <br />o <br />E <br />z� <br />Z® <br />Z <br />0 <br />coco U <br />O <br />a o <br />� <br />J <br />d <br />az <br />uo <br />� o <br />�pa <br />o l <br />wz <br />N � <br />o <br />o! � <br />i. <br />ro <br />_ <br />o <br />o <br />zLL <br />Z <br />Q% <br />J <br />y m <br />° <br />Q W <br />�z <br />N 3 <br />a <br />2. <br />LL <br />ao <br />�w <br />WcL <br />o <br />w� <br />w� <br />�o <br />c0 <br />zaTo3 <br />2 O <br />2 <br />In <br />o <br />co <br />M <br />m <br />0 <br />W <br />O <br />O <br />N <br />Q <br />U <br />2 <br />O <br />0— <br />C ° <br />m <br />O <br />� <br />E <br />lit <br />T <br />v <br />0) <br />N <br />• <br />I' CD <br />LO <br />= <br />M LO <br />r <br />N <br />z <br />cc <br />Z <br />; <br />E O <br />N <br />w <br />to <br />a <br />ci <br />Q o <br />JOB <br />NO: <br />21-5013 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />