6400 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6400 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 3:12:22 PM
Creation date
2/19/2025 10:27:31 AM
Metadata
Fields
Template:
Building Plans
Street #
6400
Location
Beverly Hills Dr
Contractor
Lennar Homes
Building Plans - Permit #
5253
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tt� >da.Irlf�t+g <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />PANEL CENTER <br />NEMA1 <br />150 AMPI <br />200 AMP <br />to lights & outlets <br />to appliances and GFI <br />to WH <br />D Range <br />DHVAC <br />so=2ro <br />200=410 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND <br />isconnect <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />J CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES. <br />Typical 150-200 Amp Electrical Riser Diagram REV.03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16"AFF (general). <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor Who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />FE�CG.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />f� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />Cb3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />e <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />IQI <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />SECOND FLOOR ELECTRICAL PLAN — ELEV—B1 <br />SCALE: Y4'=1'-0" <br />N <br />N <br />c� <br />C <br />o <br />> <br />C W <br />O <br />� s <br />roveti <br />'D cc <br />N L.L. d <br />0 � <br />fV <br />W c c n> <br />(�•, Cl Q <br />3 cc <br />� <br />m <br />T <br />c E <br />t9 0 <br />a I.a <br />0 <br />N <br />N <br />0 <br />N <br />M <br />i <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0 <br />a <br />E <br />o 8 <br />v <br />O <br />LQ <br />N d C01 <br />.2coy ie m <br />a� <br />0) <br />0) <br />a <br />fi N G � ik U. <br />N fh J , <br />=J LL W <br />LL LL o <br />a <br />Z <br />`° ` °' <br />2 <br />t� <br />W_ <br />CS <br />LL <br />co <br />rn Z <br />N OU <br />= <br />W <br />y <br />013 <br />c� <br />Cl) <br />Z N <br />Z <br />z <br />a $ <br />a <br />13 <br />TV) <br />z0 <br />1)'�_ <br />LL <br />(O <br />'U <br />N <br />LU <br />�0 <br />"' <br />LU <br />C) <br />• <br />_ <br />f <br />W <br />z <br />M <br />p <br />< <br />a <br />l g <br />wLL=® <br />a <br />E05 <br />o� <br />E U <br />ao <br />X V <br />0 <br />Z <br />O E <br />N <br />oa <br />Eo <br /><g <br />aI <br />�w <br />� <br />ao <br />m� <br />- r0 <br />c <br />0 <br />0 <br />zZ <br />Z <br />- N <br />J <br />"� <br />aw <br />i <br />u� <br />a� <br />a� <br />O � <br />Z U <br />o <br />W <br />U <br />w. <br /><� <br />w <br />yky- <br />h" <br />J W <br />Q � <br />_ <br />O = <br />> <br />IIIIIIIIII' <br />Q <br />t0 <br />et <br />� <br />1% <br />a S <br />ov 3 <br />C <br />LOv, <br />, ^ <br />Y , <br />Q <br />M <br />C� <br />Y <br />'Cr <br />m <br />� <br />T <br />¢I <br />� <br />0 <br />N <br />O <br />O <br />N <br />T <br />LO <br />11710 <br />Q <br />r <br />ai <br />o <br />Z <br />zE <br />M <br />�' <br />it <br />U <br />Q p <br />JOB <br />NO: <br />22-06471 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />