Laserfiche WebLink
c <br />v <br />v <br />_ <br />CV <br />u7 <br />S <br />N <br />r` <br />L2 <br />I <br />00 <br />_ <br />e7 <br />r` <br />L0 <br />N <br />rY <br />_ <br />X) <br />O <br />O <br />O <br />J <br />CD <br />CD <br />00 <br />ATTIC VENTILATION CALCULATIONS - Al <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev ) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />0.000000 <br />0.000000 <br />Floor <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0.0 <br />0.0 <br />0.0 <br />(Zone 1) <br />Upper <br />9 <br />2.000000 <br />Floor <br />1535 <br />1474 <br />211 <br />737 <br />53 <br />368 <br />411.0 <br />276.0 <br />(Zone 2) <br />135.0 <br />"NOTE" <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN <br />SCALE: %4'=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />—CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN" <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SO. IN. OF NET FREE AREA! LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ, FT. <br />0IFNI <br />°Z M <br />_ o <br />z° <br />Z <br />0 <br />z <br />CZ <br />V) (D <br />QJ w <br />n3 � <br />�V — <br />Ow <br />o <br />U <br />or- <br />CoN <br />W <br />W M <br />g ra C1> <br />-O co <br />S N <br />N <br />Q p � <br />Ly <br />�LL00 <br />=40 <br />O <br />rn Q o <br />B D. <br />N f <br />N �D <br />4 O V� N <br />U) O th O� <br />SIC"- <br />Z W C6.z <br />U) Z � <br />I—. . <br />cos w <br />W Nv w <br />mLC1 <br />a <br />Z <br />a� < <br />LLM <br />_ < _r <br />U <br />.r,��,r/IEtdtf (t 4 fttltitt\����� <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />L N A R <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />O <br />Z <br />O <br />w� <br />za <br />f �¢ <br />W¢C� a. <br />U <br />�MOo <br />ZnZof <br />�Ow <br />uz, <br />0 J <br />W 2 <br />LL N <br />Q <br />gZ <br />^�— <br />o <br />��/ <br />LI <br />^ <br />M Z <br />g <br />Z <br />w <br />..� <br />Z <br />0 <br />< <br />a <br />J W <br />UJ^ <br />L.L <br />Ooz <br />F O <br />UO <br />T21111 <br />Q <br />aJOC <br />Lr) <br />O <br />LUUQwWO�Q <br />w/ <br />Q <br />-0-mcOW[ <br />Q <br />0 <br />Z <br />� <br />J <br />In <br />LJ_I <br />Q W LL <br />o U <br />Lu <br />M{. <br />^ <br />Q <br />Z <br />Z <br />I-- <br />� Q <br />a N p <br />Z <br />0 <br />V/ <br />Z <br />g <br />w <br />UJ <br />= <br />J0 <br />¢� <br />rn <br />T-11 <br />a <br />V) <br />o <br />SCALE : AS NOTED <br />DATE : 7/31 /2018 <br />TECH: WAM ES <br />VERSION NO. 5ol <br />SHEET NO. <br />5.0 <br />t <br />4 <br />s--ii, o Fai.,a urCi1r �irut-i�, rtI I117jiiAr:-r1 �. 1 ,d lar 4..��` <br />