Laserfiche WebLink
a=i <br />v <br />x <br />CV <br />LO <br />0 <br />cV <br />r- <br />Co <br />�2 <br />Q <br />LO <br />r1_ <br />LO <br />CV <br />it <br />v <br />to <br />0 <br />0 <br />J <br />M <br />tR <br />Q <br />co <br />E <br />O <br />S <br />tZ <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />01 #14 copperto lights & outlets <br />NEMA 1 <br />200 AMP <br />00 #12 copperto 20 amp ckts <br />10 #10-2 copperto WH <br />10 #10-3 copper to Dryer <br />METER <br />MAIN <br />O210 <br />or <br />4/0 SER Alu <br />200 amp <br />150 amp <br />POWER CO. FEED----_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation, <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4. <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />Q <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />N 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G7J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FC" ...�.. <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />UPPER ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />Z M <br />C� <br />— o <br />z N <br />z� <br />J <br />d <br />U, Z <br />n� <br />W cry <br />�w <br />�o <br />�V — <br />0 W <br />m N <br />LLJ <br />E— <br />C Co M <br />— U <br />O O N <br />o <br />U <br />r�0 <br />= LL <br />ono <br />¢M <br />U.)Qv <br />rn Q o <br />B I <br />w <br />'r <br />_ N <br />LU O v N <br />q <br />0? C <br />U) Z W <br />�. i � � CD <br />W <br />10 W V >�'�a a <br />Z Q m a OxO <br />to N .� o04 w C4 <br />LL Z Q¢M Q <br />WCD <br />O C> U O <br />Li ❑ <br />WWW.FDSENG.COM <br />C10 <br />0 <br />CV <br />C14 <br />0 <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />13 <br />oZ <br />0 <br />Lu <br />fa <br />z <br />W<rX <br />rE00 <br />J <br />�— <br />Z Z <br />z <br />J <br />UOwuj <br />�Kg—t <br />Q <br />n co <br />O�I <br />U <br />UWLL'R <br />m � <br />H <br />UZ <br />i Z <br />oC <br />W <br />::) <br />W <br />�3 <br />N <br />_0 <br />2 <br />a <br />V <br />J W <br />L <br />U <br />V <br />O <br />Lu <br />° °KKK o <br />r— Y r <br />r <br />0t <br />J <br />V-- <br /><�S <br />Lf) <br />Z <br />LLI 0 <br />U elf 0Q <br />* <br />N <br />N <br />Q <br /><W <br />� <br />Q <br />�o�o <br />°o W o <br />Z <br />Z <br />LL 0 O <br />W <br />LP) <br />LU <br />2: <br />Lij <br />Q <br />W o <br />Ia- <br />l0 <br />M <br />Q <br />Z <br />Z <br /><<o <br />�O <br />Z <br />zo <br />° <br />m <br />G[ <br />J <br />W <br />= <br />a Z <br />o <br />r__1 <br />a <br />to <br />o <br />SCALE : AS NOTED <br />DATE : 7/31 /2018 <br />TECH: MJAM ES <br />VERSION N0. 5ol <br />SHEET NO. <br />4.1 <br />IN t r, 1 0; iJ dill.ut.. -- i <br />